VCI value for side B, the atm side, of an
in-band management-atm connection. Valid range
is a number between 0 and 65535.
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
VCI value for side B, the atm side, of an
in-band management-atm connection. Valid range
is a number between 0 and 65535.
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
ipAtmAppPvcVccVciB OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "VCI value for side B, the atm side, of an in-band management-atm connection. Valid range is a number between 0 and 65535." ::= { ipAtmAppPvcVccEntry 5 }
ipAtmAppPvcVccVciB OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "VCI value for side B, the atm side, of an in-band management-atm connection. Valid range is a number between 0 and 65535." ::= { ipAtmAppPvcVccEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.6.4.1.1 | ipAtmAppPvcVccDestAddrA | 0 | 0 | Destination IP address of an in-band management- atm connection. Value is and IP address. |
1.3.6.1.4.1.1751.2.18.6.4.1.2 | ipAtmAppPvcVccSubnetMaskA | 0 | 0 | The subnet mask of the destination IP address. Value is an IP address. |
1.3.6.1.4.1.1751.2.18.6.4.1.3 | ipAtmAppPvcVccIfB | 0 | 0 | Interface index for side B, the atm side, of an in-band management-atm connection. Number value is interpreted as an interface o… |
1.3.6.1.4.1.1751.2.18.6.4.1.4 | ipAtmAppPvcVccVpiB | 0 | 0 | VPI value for side B, the atm side, of an in-band management-atm connection. Valid range is a number between 0 and 4095. |
1.3.6.1.4.1.1751.2.18.6.4.1.6 | ipAtmAppPvcVccServiceTypeA2B | 0 | 0 | Service type from side A to B |
1.3.6.1.4.1.1751.2.18.6.4.1.7 | ipAtmAppPvcVccServiceTypeB2A | 0 | 0 | Service type from side B to A |
1.3.6.1.4.1.1751.2.18.6.4.1.8 | ipAtmAppPvcVccPeakCellRateB2A | 0 | 0 | peak rate - side B |
1.3.6.1.4.1.1751.2.18.6.4.1.9 | ipAtmAppPvcVccSusCellRateB2A | 0 | 0 | sustained rate - side B |
1.3.6.1.4.1.1751.2.18.6.4.1.10 | ipAtmAppPvcVccMaxBurstSizeB2A | 0 | 0 | maximum burst size - side B |
1.3.6.1.4.1.1751.2.18.6.4.1.11 | ipAtmAppPvcVccType | 0 | 0 | Indicated in-band management atm connection type. |
1.3.6.1.4.1.1751.2.18.6.4.1.12 | ipAtmAppPvcVccRowStatus | 0 | 0 | row status |
1.3.6.1.4.1.1751.2.18.6.4.1.13 | ipAtmAppPvcVccConnectionStatus | 0 | 0 | Indicates the current connections status. Active: All interfaces through which the connection is going are in service. Inactive: … |
1.3.6.1.4.1.1751.2.18.6.4.1.14 | ipAtmAppPvcVccDualHomed | 0 | 0 | Does this PVC need a backup Dual homing PVC. |
1.3.6.1.4.1.1751.2.18.6.4.1.15 | ipAtmAppPvcVccViB | 0 | 0 | VI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.4.1.16 | ipAtmAppPvcVccCnfrmTypeB2A | 0 | 0 | The following is the description of this field This will be used in conjunction with the service type field to get the correct tra… |
1.3.6.1.4.1.1751.2.18.6.4.1.17 | ipAtmAppPvcVccVUNIB | 0 | 0 | VUNI to associate the Egress part of the A2B connection . |
1.3.6.1.4.1.1751.2.18.6.4.1.18 | ipAtmAppPvcVccMfsB2A | 0 | 0 | Maximum Frame Size for GFR traffic |
1.3.6.1.4.1.1751.2.18.6.4.1.19 | ipAtmAppPvcVccConnFailureCauseB | 0 | 0 | connection status reason code |
1.3.6.1.4.1.1751.2.18.6.4.1.20 | ipAtmAppPvcVccTrafficShapingA2B | 0 | 0 | Traffic Shaping Support in the A2B direction. |
1.3.6.1.4.1.1751.2.18.6.4.1.21 | ipAtmAppPvcVccOamStatus | 0 | 0 | Indicates the OAM monitoring status. The 3 possible states are: Unsupp: No monitoring enabled. End-Pt: A side is only an end poi… |