When operated in cellAtmUniHec or cellAtmUniPlcp modes, the
counter associated with the number of cells with both VPI and
VCI equal to 0 encountered by a Cell port in the current 15
minute interval.
In cellSmdsSniPlcp or cellSmdsSniPlcpNoMux modes, the counter
associated with the number of L2 PDUs with Busy Bit == 0
encountered by a Cell port in the current 15 minute interval.
Parsed from file CP300.mib.txt
Company: marconi
Module: AAC3-MIB
Vendor: ADC Kentrox
Module: AAC3-MIB (aac3-140.mib)
Type: TABULAR
Access: read-only
Syntax: Gauge
Automatically extracted from www.mibdepot.com
cellCurrentInEmptyCells OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of cells with both VPI and VCI equal to 0 encountered by a Cell port in the current 15 minute interval. In cellSmdsSniPlcp or cellSmdsSniPlcpNoMux modes, the counter associated with the number of L2 PDUs with Busy Bit == 0 encountered by a Cell port in the current 15 minute interval." ::= { cellCurrentEntry 14 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.1.13.6.6.2.1.1 | cellCurrentIndex | 0 | 0 | This variable uniquely identifies the Cell port for which this table entry applies. It has the same value as the cellPortIndex v… |
1.3.6.1.4.1.181.1.13.6.6.2.1.2 | cellCurrentBip8s | 0 | 0 | The counter associated with the number of BIP-8 errors, encountered by a Cell port in the current 15 minute interval. |
1.3.6.1.4.1.181.1.13.6.6.2.1.3 | cellCurrentPlcpEFSs | 0 | 0 | The counter associated with the number of PLCP Errored Framing Seconds, encountered by a Cell port in the current 15 minute inter… |
1.3.6.1.4.1.181.1.13.6.6.2.1.4 | cellCurrentPlcpSEFSs | 0 | 0 | The counter associated with the number of PLCP Severely Errored Framing Seconds, encountered by a Cell port in the current 15 min… |
1.3.6.1.4.1.181.1.13.6.6.2.1.5 | cellCurrentPlcpUASs | 0 | 0 | The counter associated with the number of PLCP Unavailable Seconds, encountered by a Cell port in the current 15 minute interval. |
1.3.6.1.4.1.181.1.13.6.6.2.1.6 | cellCurrentInHecErrCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of HEC errored cells encountered b… |
1.3.6.1.4.1.181.1.13.6.6.2.1.7 | cellCurrentInInvalidCells | 0 | 0 | The counter associated with the number of cells whose VPI/VCI does not match any current connection encountered by a Cell port in… |
1.3.6.1.4.1.181.1.13.6.6.2.1.8 | cellCurrentInGoodBusyVbrCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of VBR cells received by a Cell po… |
1.3.6.1.4.1.181.1.13.6.6.2.1.9 | cellCurrentInGoodBusyCbrCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of CBR cells received by a Cell po… |
1.3.6.1.4.1.181.1.13.6.6.2.1.10 | cellCurrentOutCgstnTossedCells | 0 | 0 | The counter associated with the number of cells tossed by the rate controller for whatever reason by a Cell port in the current 1… |
1.3.6.1.4.1.181.1.13.6.6.2.1.11 | cellCurrentOutPcrTossedCells | 0 | 0 | The counter associated with the number of cells tossed by the rate controller for violating the PCR by a Cell port in the current… |
1.3.6.1.4.1.181.1.13.6.6.2.1.12 | cellCurrentOutBusyVbrCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the counter associated with the number of VBR cells transmitted by a Cell… |
1.3.6.1.4.1.181.1.13.6.6.2.1.13 | cellCurrentOutBusyCbrCells | 0 | 0 | When operated in cellAtmUniHec or cellAtmUniPlcp modes, the the counter associated with the number of CBR cells transmitted by a … |
1.3.6.1.4.1.181.1.13.6.6.2.1.15 | cellCurrentFebes | 0 | 0 | The counter associated with the number of FEBE errors encountered by a Cell port in the current 15 minute interval. |