Vendor: ADC Kentrox
Module: DATASMART-MIB
[Automatically extracted from oidview.com]
dsNc OBJECT IDENTIFIER ::= { datasmart 11 }
dsNc OBJECT IDENTIFIER ::= { datasmart 11 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.2.2.11.1 | dsNcFraming | 1 | 1 | The type of framing being used on the Network Interface. The possible values are: VALUE DESCRIPTION ncSF(1) … |
1.3.6.1.4.1.181.2.2.11.2 | dsNcCoding | 1 | 1 | The type of line coding being used on the Network Interface. The possible values are: VALUE DESCRIPTION ncAmi(1) … |
1.3.6.1.4.1.181.2.2.11.3 | dsNcT1403 | 1 | 1 | This object enables/disables the sending of T1.403 PRM messages. The possible values are: VALUE DESCRIPTION ncT1403En… |
1.3.6.1.4.1.181.2.2.11.4 | dsNcYellow | 1 | 1 | This object enables/disables sending Yellow alarm out the Network Interface upon receipt of an alarm on the Network Interface. Th… |
1.3.6.1.4.1.181.2.2.11.5 | dsNcAddr54 | 1 | 1 | If 54016 addressing is enabled, this object determines what type of addressing the unit responds to. The possible values are: VALU… |
1.3.6.1.4.1.181.2.2.11.6 | dsNc54016 | 1 | 1 | This object determines whether the unit responds to 54016 addressing modes. The possible values are: VALUE DESCRIPTI… |
1.3.6.1.4.1.181.2.2.11.7 | dsNcLbo | 1 | 1 | The Network Interface Line Build Out setting. The possible values are: VALUE DESCRIPTION ncLbo0(1) 0.0dB line … |
1.3.6.1.4.1.181.2.2.11.8 | dsNcMF16 | 1 | 1 | The E1 network interface Time Slot 16 MultiFrame alignment signal setting. The possible values are: VALUE DESCRIPTION… |
1.3.6.1.4.1.181.2.2.11.9 | dsNcCRC | 1 | 1 | The E1 network interface CRC generation/checking setting. The possible values are: VALUE DESCRIPTION ncCrcEnable(1) … |
1.3.6.1.4.1.181.2.2.11.10 | dsNcFasAlign | 1 | 1 | The E1 network interface Time Slot 0 NOT-FAS Word setting. The possible values are: VALUE DESCRIPTION ncFasWord(1) … |
1.3.6.1.4.1.181.2.2.11.11 | dsNcE1DLPath | 1 | 1 | The E1 network interface Sa bit usage. If Sa bits are being used for data link communications, both the near and far end units mu… |
1.3.6.1.4.1.181.2.2.11.12 | dsNcKA | 1 | 1 | The status of sending E1 remote Frame Alarm into the NI during alarms. The Possible values are: VALUE DESCRIPTION nc… |
1.3.6.1.4.1.181.2.2.11.13 | dsNcGenRfa | 1 | 1 | The status of sending E1 remote Frame Alarm into the NI during alarms. The Possible values are: VALUE DESCRIPTION ncG… |
1.3.6.1.4.1.181.2.2.11.14 | dsNcPassTiRfa | 1 | 1 | The status of sending the RFA received on the network interface out the terminal interface. This function is not possible on a DS… |
1.3.6.1.4.1.181.2.2.11.15 | dsNcIdle | 1 | 1 | The idle code to be transmited in the idle NI and TI channels. This code is also sent in all TI channels when the TI is experienc… |
1.3.6.1.4.1.181.2.2.11.16 | dsNcDdsType | 1 | 1 | The Possible values are: VALUE DESCRIPTION scDds56K(1) Set unit to 56K Operation scDds64K(2) … |
1.3.6.1.4.1.181.2.2.11.17 | dsNcTs16 | 1 | 1 | Configures the value of Time Slot 16 in an E1 unit. Support for older commands is supported but has been combined into one easie… |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.2.2.1 | dsSs | 4 | 8 | None |
1.3.6.1.4.1.181.2.2.2 | dsRp | 12 | 244 | None |
1.3.6.1.4.1.181.2.2.3 | dsLm | 3 | 6 | None |
1.3.6.1.4.1.181.2.2.4 | dsRm | 12 | 62 | None |
1.3.6.1.4.1.181.2.2.5 | dsAc | 9 | 18 | None |
1.3.6.1.4.1.181.2.2.6 | dsCc | 8 | 16 | None |
1.3.6.1.4.1.181.2.2.7 | dsDc | 1 | 11 | None |
1.3.6.1.4.1.181.2.2.8 | dsFc | 3 | 9 | None |
1.3.6.1.4.1.181.2.2.9 | dsFmc | 10 | 20 | None |
1.3.6.1.4.1.181.2.2.10 | dsMc | 14 | 46 | None |
1.3.6.1.4.1.181.2.2.12 | dsSc | 27 | 54 | None |
1.3.6.1.4.1.181.2.2.13 | dsTc | 10 | 20 | None |
1.3.6.1.4.1.181.2.2.14 | dsFp | 2 | 48 | None |
1.3.6.1.4.1.181.2.2.15 | dsVer | 1 | 2 | None |
1.3.6.1.4.1.181.2.2.5005 | dsAcOnPowerTransition | 0 | 0 | None |
1.3.6.1.4.1.181.2.2.5006 | dsAcOffPowerTransition | 0 | 0 | None |
1.3.6.1.4.1.181.2.2.9001 | dsFmcSetNiRcvUpperBwThresh | 0 | 0 | None |
1.3.6.1.4.1.181.2.2.9002 | dsFmcClrNiRcvUpperBwThresh | 0 | 0 | None |
1.3.6.1.4.1.181.2.2.9003 | dsFmcSetNiXmtUpperBwThresh | 0 | 0 | None |
1.3.6.1.4.1.181.2.2.9004 | dsFmcClrNiXmtUpperBwThresh | 0 | 0 | None |
1.3.6.1.4.1.181.2.2.9005 | dsFmcFpingLinkDown | 0 | 0 | None |
1.3.6.1.4.1.181.2.2.9006 | dsFmcFpingLinkUp | 0 | 0 | None |