The source of the timing clock. The various options
are:
VALUE DESCRIPTION
scTerminalTiming(1) Use the clock coming in on
the Terminal Interface
scThroughTiming(2) Use Through timing NI rx
to Ti tx and TI rx to NI tx
scInternalTiming(3) Use the internal clock
scLoopTiming(4) Use the clock from the network
scDP1Timing(5) Use the clock coming in on
data port 1
scDP2Timing(6) Use the clock coming in on
data port 2
Parsed from file datasmart_14304.mib.txt
Company: None
Module: DATASMART-MIB
The source of the timing clock. The various options
are:
VALUE DESCRIPTION
scTerminalTiming(1) Use the clock coming in on
the Terminal Interface
scThroughTiming(2) Use Through timing NI rx
to Ti tx and TI rx to NI tx
scInternalTiming(3) Use the internal clock
scLoopTiming(4) Use the clock from the network
scDP1Timing(5) Use the clock coming in on
data port 1
scDP2Timing(6) Use the clock coming in on
data port 2
Parsed from file DATASMART-MIB.mib
Module: DATASMART-MIB
Vendor: ADC Kentrox
Module: DATASMART-MIB
[Automatically extracted from oidview.com]
dsScClockSource OBJECT-TYPE SYNTAX INTEGER { scTerminalTiming (1), scThroughTiming (2), scInternalTiming (3), scLoopTiming (4), scDP1Timing (5), scDP2Timing (6) } ACCESS read-write STATUS mandatory DESCRIPTION "The source of the timing clock. The various options are: VALUE DESCRIPTION scTerminalTiming(1) Use the clock coming in on the Terminal Interface scThroughTiming(2) Use Through timing NI rx to Ti tx and TI rx to NI tx scInternalTiming(3) Use the internal clock scLoopTiming(4) Use the clock from the network scDP1Timing(5) Use the clock coming in on data port 1 scDP2Timing(6) Use the clock coming in on data port 2" ::= { dsSc 12 }
dsScClockSource OBJECT-TYPE SYNTAX INTEGER { scTerminalTiming (1), scThroughTiming (2), scInternalTiming (3), scLoopTiming (4), scDP1Timing (5), scDP2Timing (6) } ACCESS read-write STATUS mandatory DESCRIPTION "The source of the timing clock. The various options are: VALUE DESCRIPTION scTerminalTiming(1) Use the clock coming in on the Terminal Interface scThroughTiming(2) Use Through timing NI rx to Ti tx and TI rx to NI tx scInternalTiming(3) Use the internal clock scLoopTiming(4) Use the clock from the network scDP1Timing(5) Use the clock coming in on data port 1 scDP2Timing(6) Use the clock coming in on data port 2" ::= { dsSc 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.2.2.12.12.0 | dsScClockSource | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.2.2.12.1 | dsScMonth | 1 | 1 | The calendar number of the current month. 1 is January. |
1.3.6.1.4.1.181.2.2.12.2 | dsScDay | 1 | 1 | The number of the current day. |
1.3.6.1.4.1.181.2.2.12.3 | dsScYear | 1 | 1 | The number of the current year. 95 is 1995. |
1.3.6.1.4.1.181.2.2.12.4 | dsScHour | 1 | 1 | The number of the current hour. 0 is 12:00am. |
1.3.6.1.4.1.181.2.2.12.5 | dsScMinutes | 1 | 1 | The number of the current minute. |
1.3.6.1.4.1.181.2.2.12.6 | dsScName | 1 | 1 | The Site Name of the unit. |
1.3.6.1.4.1.181.2.2.12.7 | dsScSlotAddr | 1 | 1 | The Kentrox-specific slot address. The 01 in the address 01:02:003. |
1.3.6.1.4.1.181.2.2.12.8 | dsScShelfAddr | 1 | 1 | The Kentrox-specific shelf address. The 02 in the address 01:02:003. |
1.3.6.1.4.1.181.2.2.12.9 | dsScGroupAddr | 1 | 1 | The Kentrox-specific group address. The 003 in the address 01:02:003. |
1.3.6.1.4.1.181.2.2.12.10 | dsScFrontPanel | 1 | 1 | The status of the front panel buttons. The possible values are: VALUE DESCRIPTION scFpEnable(1) Enable the front p… |
1.3.6.1.4.1.181.2.2.12.11 | dsScDSCompatible | 1 | 1 | The status of the datasmart compatibility function. This should be set to scDSEnabled(1) when the far end unit is a eariler model… |
1.3.6.1.4.1.181.2.2.12.13 | dsScAutologout | 1 | 1 | The time (in minutes) to wait for a keypress before logging the current user out. If this object is set to 0, autologout is disab… |
1.3.6.1.4.1.181.2.2.12.14 | dsScZeroPerData | 1 | 1 | This object will zero all performance report counters if it is set to scZallStart(2). |
1.3.6.1.4.1.181.2.2.12.15 | dsScWyv | 1 | 1 | The string returned by the user interface command WYV, What's Your Version. |
1.3.6.1.4.1.181.2.2.12.16 | dsScAutoCfg | 1 | 1 | This object enables/disables the Auto-Configuration feature, which allows units in a daisy chain to be automatically configured b… |
1.3.6.1.4.1.181.2.2.12.17 | dsScTftpSwdl | 1 | 1 | A text string used to initiate or check the status of a TFTP file transfer operation for doing a software download. To initiate … |
1.3.6.1.4.1.181.2.2.12.18 | dsScBoot | 1 | 1 | This variable is used to force a system reboot: scBootIdle Does nothing. scBootActive Reboots from the executing FLASH RO… |
1.3.6.1.4.1.181.2.2.12.19 | dsScOperMode | 1 | 1 | fill in later. scTransparentMode Unit doesn't monitor FR traffic scMonitorMode Unit monitors FR traffic |
1.3.6.1.4.1.181.2.2.12.20 | dsScYearExtention | 1 | 1 | . |
1.3.6.1.4.1.181.2.2.12.21 | dsScMonthExtention | 1 | 1 | . |
1.3.6.1.4.1.181.2.2.12.22 | dsScDayExtention | 1 | 1 | . |
1.3.6.1.4.1.181.2.2.12.23 | dsScHourExtention | 1 | 1 | . |
1.3.6.1.4.1.181.2.2.12.24 | dsScMinExtention | 1 | 1 | . |
1.3.6.1.4.1.181.2.2.12.25 | dsScSecExtention | 1 | 1 | . |
1.3.6.1.4.1.181.2.2.12.26 | dsScPinK | 1 | 1 | . |
1.3.6.1.4.1.181.2.2.12.27 | dsScBootP | 1 | 1 | The BOOTP mode, which defines if BOOTP requests should be transmitted, and if so on which start up sequences. The possible value… |