The error conditions encountered by a DS1/E1
interface in one of the pervious 96 15-minute
intervals. The error conditions are signified by
a single character. The possible values are:
VALUE DESCRIPTION
C A CRC error has been detected on the
received T1/E1 signal
B A bipolar (line) violation has occurred
on the received T1/E1 signal
L A LOS condition (but not necessarily an
alarm) has occurred on the received
T1/E1 signal
O An OOF condition (but not necessarily an
alarm) has occurred on the received
T1/E1
E An EER condition (but not necessarily an
alarm) has occurred on the received
T1/E1 signal
A An AIS condition (but not necessarily an
alarm) has occurred on the received
T1/E1 signal
Y A Yellow alarm has occurred on the received
T1/E1 signal
S A controlled slip has occurred on the
received T1/E1 signal
@ There is an active alarm
T There is a loop back, code generation,
or BERT active
N The unit was without power
Parsed from file datasmart_14304.mib.txt
Company: None
Module: DATASMART-MIB
The error conditions encountered by a DS1/E1
interface in one of the pervious 96 15-minute
intervals. The error conditions are signified by
a single character. The possible values are:
VALUE DESCRIPTION
C A CRC error has been detected on the
received T1/E1 signal
B A bipolar (line) violation has occurred
on the received T1/E1 signal
L A LOS condition (but not necessarily an
alarm) has occurred on the received
T1/E1 signal
O An OOF condition (but not necessarily an
alarm) has occurred on the received
T1/E1
E An EER condition (but not necessarily an
alarm) has occurred on the received
T1/E1 signal
A An AIS condition (but not necessarily an
alarm) has occurred on the received
T1/E1 signal
Y A Yellow alarm has occurred on the received
T1/E1 signal
S A controlled slip has occurred on the
received T1/E1 signal
@ There is an active alarm
T There is a loop back, code generation,
or BERT active
N The unit was without power
Parsed from file DATASMART-MIB.mib
Module: DATASMART-MIB
Vendor: ADC Kentrox
Module: DATASMART-MIB
[Automatically extracted from oidview.com]
dsRpUsrIntvlStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "The error conditions encountered by a DS1/E1 interface in one of the pervious 96 15-minute intervals. The error conditions are signified by a single character. The possible values are: VALUE DESCRIPTION C A CRC error has been detected on the received T1/E1 signal B A bipolar (line) violation has occurred on the received T1/E1 signal L A LOS condition (but not necessarily an alarm) has occurred on the received T1/E1 signal O An OOF condition (but not necessarily an alarm) has occurred on the received T1/E1 E An EER condition (but not necessarily an alarm) has occurred on the received T1/E1 signal A An AIS condition (but not necessarily an alarm) has occurred on the received T1/E1 signal Y A Yellow alarm has occurred on the received T1/E1 signal S A controlled slip has occurred on the received T1/E1 signal @ There is an active alarm T There is a loop back, code generation, or BERT active N The unit was without power" ::= { dsRpUsrIntvlEntry 10 }
dsRpUsrIntvlStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "The error conditions encountered by a DS1/E1 interface in one of the pervious 96 15-minute intervals. The error conditions are signified by a single character. The possible values are: VALUE DESCRIPTION C A CRC error has been detected on the received T1/E1 signal B A bipolar (line) violation has occurred on the received T1/E1 signal L A LOS condition (but not necessarily an alarm) has occurred on the received T1/E1 signal O An OOF condition (but not necessarily an alarm) has occurred on the received T1/E1 E An EER condition (but not necessarily an alarm) has occurred on the received T1/E1 signal A An AIS condition (but not necessarily an alarm) has occurred on the received T1/E1 signal Y A Yellow alarm has occurred on the received T1/E1 signal S A controlled slip has occurred on the received T1/E1 signal @ There is an active alarm T There is a loop back, code generation, or BERT active N The unit was without power" ::= { dsRpUsrIntvlEntry 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.2.2.2.1.3.1.1 | dsRpUsrIntvlIndex | 0 | 0 | The index for the User Interval Table. The valid values for this index are: VALUE DESCRIPTION 1 Network Interface 2 T… |
1.3.6.1.4.1.181.2.2.2.1.3.1.2 | dsRpUsrIntvlNum | 0 | 0 | This is the interval number of the User Interval Table. It will be the number of completed 15-minute intervals since the unit has… |
1.3.6.1.4.1.181.2.2.2.1.3.1.3 | dsRpUsrIntvlEE | 0 | 0 | The number of Event Errors encountered by a DS1/E1 interface in one of the previous 96 15-minute intervals. |
1.3.6.1.4.1.181.2.2.2.1.3.1.4 | dsRpUsrIntvlES | 0 | 0 | The number of Errored Seconds encountered by a DS1/E1 interface in one of the previous 96 15-minute intervals. |
1.3.6.1.4.1.181.2.2.2.1.3.1.5 | dsRpUsrIntvlBES | 0 | 0 | The number of Bursty Errored Seconds encountered by a DS1/E1 interface in one of the pervious 96 15-minute intervals. |
1.3.6.1.4.1.181.2.2.2.1.3.1.6 | dsRpUsrIntvlSES | 0 | 0 | The number of Severely Errored Seconds encountered by a DS1/E1 interface in one of the previous 96 15-minute intervals. |
1.3.6.1.4.1.181.2.2.2.1.3.1.7 | dsRpUsrIntvlUAS | 0 | 0 | The number of Unavailable Seconds encountered by a DS1/E1 interface in one of the previous 96 15-minute intervals. |
1.3.6.1.4.1.181.2.2.2.1.3.1.8 | dsRpUsrIntvlCSS | 0 | 0 | The number of Controlled Slip Seconds encountered by a DS1/E1 interface in one of the previous 96 15-minute intervals. |
1.3.6.1.4.1.181.2.2.2.1.3.1.9 | dsRpUsrIntvlDM | 0 | 0 | The number of Degraded Minutes encountered by a DS1/E1 interface in one of the previous 96 15-minute intervals. |