This object controls the activation of BERT tests.
The possible values are:
VALUE DESCRIPTION
rmBertNone(1) No BERT test is active
rmBertQrs(2) BERT for QRS
rmBert324(3) BERT for 3-in-24
rmBertOnes(4) BERT for all ones
rmBertZeros(5) BERT for all zeros
rmBert511Dp1(6) BERT for 511 on data port 1
rmBert511Dp2(7) BERT for 511 on data port 2
rmBert2047Dp1(8) BERT for 2047 on data port 1
rmBert2047Dp2(9) BERT for 2047 on data port 2
rmTest2toThe23(10) BERT for 2 to the 23
rmTest2toThe15(11) BERT for 2 to the 15
Parsed from file datasmart_14304.mib.txt
Company: None
Module: DATASMART-MIB
This object controls the activation of BERT tests.
The possible values are:
VALUE DESCRIPTION
rmBertNone(1) No BERT test is active
rmBertQrs(2) BERT for QRS
rmBert324(3) BERT for 3-in-24
rmBertOnes(4) BERT for all ones
rmBertZeros(5) BERT for all zeros
rmBert511Dp1(6) BERT for 511 on data port 1
rmBert511Dp2(7) BERT for 511 on data port 2
rmBert2047Dp1(8) BERT for 2047 on data port 1
rmBert2047Dp2(9) BERT for 2047 on data port 2
rmTest2toThe23(10) BERT for 2 to the 23
rmTest2toThe15(11) BERT for 2 to the 15
Parsed from file DATASMART-MIB.mib
Module: DATASMART-MIB
Vendor: ADC Kentrox
Module: DATASMART-MIB
[Automatically extracted from oidview.com]
dsRmBertCode OBJECT-TYPE SYNTAX INTEGER { rmBertNone (1), rmBertQrs (2), rmBert324 (3), rmBertOnes (4), rmBertZeros (5), rmBert511Dp1 (6), rmBert511Dp2 (7), rmBert2047Dp1 (8), rmBert2047Dp2 (9), rmTest2toThe23 (10), rmTest2toThe15 (11) } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls the activation of BERT tests. The possible values are: VALUE DESCRIPTION rmBertNone(1) No BERT test is active rmBertQrs(2) BERT for QRS rmBert324(3) BERT for 3-in-24 rmBertOnes(4) BERT for all ones rmBertZeros(5) BERT for all zeros rmBert511Dp1(6) BERT for 511 on data port 1 rmBert511Dp2(7) BERT for 511 on data port 2 rmBert2047Dp1(8) BERT for 2047 on data port 1 rmBert2047Dp2(9) BERT for 2047 on data port 2 rmTest2toThe23(10) BERT for 2 to the 23 rmTest2toThe15(11) BERT for 2 to the 15" ::= { dsRm 4 }
dsRmBertCode OBJECT-TYPE SYNTAX INTEGER { rmBertNone (1), rmBertQrs (2), rmBert324 (3), rmBertOnes (4), rmBertZeros (5), rmBert511Dp1 (6), rmBert511Dp2 (7), rmBert2047Dp1 (8), rmBert2047Dp2 (9), rmTest2toThe23 (10), rmTest2toThe15 (11) } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls the activation of BERT tests. The possible values are: VALUE DESCRIPTION rmBertNone(1) No BERT test is active rmBertQrs(2) BERT for QRS rmBert324(3) BERT for 3-in-24 rmBertOnes(4) BERT for all ones rmBertZeros(5) BERT for all zeros rmBert511Dp1(6) BERT for 511 on data port 1 rmBert511Dp2(7) BERT for 511 on data port 2 rmBert2047Dp1(8) BERT for 2047 on data port 1 rmBert2047Dp2(9) BERT for 2047 on data port 2 rmTest2toThe23(10) BERT for 2 to the 23 rmTest2toThe15(11) BERT for 2 to the 15" ::= { dsRm 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.2.2.4.4.0 | dsRmBertCode | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.2.2.4.1 | dsRmLbkCode | 1 | 1 | The type of remote loopback that is currently set. The possible values are: VALUE DESCRIPTION rmRNone(1) No loo… |
1.3.6.1.4.1.181.2.2.4.2 | dsRmTestCode | 1 | 1 | The type of remote test code that is currently being sent. The possible values are: VALUE DESCRIPTION rmTestNone(1) … |
1.3.6.1.4.1.181.2.2.4.3 | dsRmBertState | 1 | 1 | The current BERT state. The possible values are: VALUE DESCRIPTION rmBertIdle(1) No BERT test is active rmBert… |
1.3.6.1.4.1.181.2.2.4.5 | dsRmBertTestSecs | 1 | 1 | The number of seconds the requested test code has been detected since the start of the BERT. |
1.3.6.1.4.1.181.2.2.4.6 | dsRmBertBitErrors | 1 | 1 | The number of bit errors detected since the start of the BERT. |
1.3.6.1.4.1.181.2.2.4.7 | dsRmBertErrdSecs | 1 | 1 | The number of errored seconds detected since the start of the BERT. |
1.3.6.1.4.1.181.2.2.4.8 | dsRmBertTotalErrors | 1 | 1 | The number of total errors detected since the start of the BERT. |
1.3.6.1.4.1.181.2.2.4.9 | dsRmBertReSync | 1 | 1 | The number of times BERT has lost and re-aquired the pattern. |
1.3.6.1.4.1.181.2.2.4.10 | dsRmFping | 13 | 26 | None |
1.3.6.1.4.1.181.2.2.4.11 | dsRmInsertBitError | 1 | 1 | Possible values are: VALUE DESCRIPTION insertBitError(1) Start sending FPINGs noInsertBitError(2) Stop s… |
1.3.6.1.4.1.181.2.2.4.12 | dsRmPing | 7 | 14 | None |