This object determines the window used to calculate
whether an Excessive Error Rate (EER) alarm should be
generated from errored seconds or unavailable seconds.
Setting this object to acSt15(1) establishes a
15-minute sliding window. Setting this object to
acSt60(2) establishes a 60-minute sliding window.
Parsed from file datasmart_14304.mib.txt
Company: None
Module: DATASMART-MIB
This object determines the window used to calculate
whether an Excessive Error Rate (EER) alarm should be
generated from errored seconds or unavailable seconds.
Setting this object to acSt15(1) establishes a
15-minute sliding window. Setting this object to
acSt60(2) establishes a 60-minute sliding window.
Parsed from file DATASMART-MIB.mib
Module: DATASMART-MIB
Vendor: ADC Kentrox
Module: DATASMART-MIB
[Automatically extracted from oidview.com]
dsAcSt OBJECT-TYPE SYNTAX INTEGER { acSt15 (1), acSt60 (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object determines the window used to calculate whether an Excessive Error Rate (EER) alarm should be generated from errored seconds or unavailable seconds. Setting this object to acSt15(1) establishes a 15-minute sliding window. Setting this object to acSt60(2) establishes a 60-minute sliding window." ::= { dsAc 6 }
dsAcSt OBJECT-TYPE SYNTAX INTEGER { acSt15 (1), acSt60 (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object determines the window used to calculate whether an Excessive Error Rate (EER) alarm should be generated from errored seconds or unavailable seconds. Setting this object to acSt15(1) establishes a 15-minute sliding window. Setting this object to acSt60(2) establishes a 60-minute sliding window." ::= { dsAc 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.2.2.5.6.0 | dsAcSt | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.2.2.5.1 | dsAcAlmMsg | 1 | 1 | This object controls the displaying/sending of alarm messages. Alarm messages will be sent in the format determined by dsAcAlmFor… |
1.3.6.1.4.1.181.2.2.5.2 | dsAcYelAlm | 1 | 1 | This object determines if incoming Yellow Alarm will cause an alarm message to be sent. Setting this object to acYelAlmEnable(1) … |
1.3.6.1.4.1.181.2.2.5.3 | dsAcDeact | 1 | 1 | This object controls the number of seconds an alarm condition must remain clear before the unit declares it cleared. The range is… |
1.3.6.1.4.1.181.2.2.5.4 | dsAcEst | 1 | 1 | This object determines the threshold of errored seconds that triggers an Excessive Error Rate (EER) alarm. Setting this object to… |
1.3.6.1.4.1.181.2.2.5.5 | dsAcUst | 1 | 1 | This object determines the threshold of uavailable seconds that triggers an Excessive Error Rate (EER) alarm. Setting this object… |
1.3.6.1.4.1.181.2.2.5.7 | dsAcBerAlm | 1 | 1 | This object controls the sending of a Bit Error Rate (BER) alarm. The possible values are: VALUE DESCRIPTION acBerAl… |
1.3.6.1.4.1.181.2.2.5.8 | dsAcRfaAlm | 1 | 1 | This object controls the sending of a Remote Frame Alarm (RFA). The possible values are: VALUE DESCRIPTION acRfaAlmE… |
1.3.6.1.4.1.181.2.2.5.9 | dsAcAisAlm | 1 | 1 | This object controls the sending of Alarm Indication Signal (AIS) alarms. The possible values are: VALUE DESCRIPTIO… |