Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"adslAtucProprietaryPhysXLastRetrainCause",
"OBJECT-TYPE",
"SYNTAX",
"OCTET",
"STRING",
"(",
"SIZE",
"(",
"1",
")",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Bit[3:0] Identifies the cause of the last initialization failure, according to the G.997.1 recommendation. Possible values are: 1 - Wrong profile (cannot occur in our system) 2 - Configuration not feasible 3 - Communication problem (CRC or time-out error) 4 - No ATU-R detected Bit[7:4] If the last initialization failure is a 'Communication problem', this field identifies the type of communication problem that has occurred. Possible values are: 0 - Timeout during initialization 1 - CRC error during initialization message 2 - Unavailable time declared during Showtime at the near-end 3 - Dynamic Rate Adaptation triggered retrain at the near-end 4 - Unavailable time declared during Showtime at the far-end 5 - Dynamic Rate Adaptation triggered retrain at the far-end 6 - Far-end line counters unavailable. If the last initialization failure is a 'Configuration not feasible' failure, this field indicates whether this applies to the upstream or downstream direction. Possible values are: 0 - Upstream configuration not feasible. 1 - Downstream configuration not feasible. Maps to the HMI GetLineStatus.lastRetrainCause\"",
"::=",
"{",
"adslAtucProprietaryPhysXEntry",
"12",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"OCTET STRING",
[
"octetStringSubType",
[
[
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Bit[3:0] Identifies the cause of the last initialization failure, according to the G.997.1 recommendation. Possible values are: 1 - Wrong profile (cannot occur in our system) 2 - Configuration not feasible 3 - Communication problem (CRC or time-out error) 4 - No ATU-R detected Bit[7:4] If the last initialization failure is a 'Communication problem', this field identifies the type of communication problem that has occurred. Possible values are: 0 - Timeout during initialization 1 - CRC error during initialization message 2 - Unavailable time declared during Showtime at the near-end 3 - Dynamic Rate Adaptation triggered retrain at the near-end 4 - Unavailable time declared during Showtime at the far-end 5 - Dynamic Rate Adaptation triggered retrain at the far-end 6 - Far-end line counters unavailable. If the last initialization failure is a 'Configuration not feasible' failure, this field indicates whether this applies to the upstream or downstream direction. Possible values are: 0 - Upstream configuration not feasible. 1 - Downstream configuration not feasible. Maps to the HMI GetLineStatus.lastRetrainCause"
],
null,
null,
null,
null
]
}