Reference record for OID 1.3.6.1.4.1.19746.2.9


parent
1.3.6.1.4.1.19746.2 (dataDomainMibNotifications)
node code
9
node name
fileSpaceWarningAlarm
dot oid
1.3.6.1.4.1.19746.2.9
type
NOTIFICATION-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dataDomainMib(19746) dataDomainMibNotifications(2) fileSpaceWarningAlarm(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dataDomainMib(19746) dataDomainMibNotifications(2) fileSpaceWarningAlarm(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dataDomainMib(19746) dataDomainMibNotifications(2) fileSpaceWarningAlarm(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dataDomainMib(19746) dataDomainMibNotifications(2) fileSpaceWarningAlarm(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dataDomainMib(19746) dataDomainMibNotifications(2) fileSpaceWarningAlarm(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dataDomainMib(19746) dataDomainMibNotifications(2) fileSpaceWarningAlarm(9)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/dataDomainMib/dataDomainMibNotifications/fileSpaceWarningAlarm
  • /iso/identified-organization/dod/internet/private/enterprises/dataDomainMib/dataDomainMibNotifications/fileSpaceWarningAlarm
  • /iso/org/dod/internet/private/enterprise/dataDomainMib/dataDomainMibNotifications/fileSpaceWarningAlarm
  • /iso/org/dod/internet/private/enterprises/dataDomainMib/dataDomainMibNotifications/fileSpaceWarningAlarm
  • /iso/iso-identified-organization/dod/internet/private/enterprise/dataDomainMib/dataDomainMibNotifications/fileSpaceWarningAlarm
  • /iso/iso-identified-organization/dod/internet/private/enterprises/dataDomainMib/dataDomainMibNotifications/fileSpaceWarningAlarm
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/19746/2/9

    Description by circitor

    Meaning: A File System Resource space is 90% utilized. The index value of the alarm indicates
    the file system index that may be looked up in the fileSystem table 'fileSystemSpace'
    for more information about the actual FS that is getting full.
    What to do: Delete unneeded files, such as old log files, support bundles, core files,
    upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding
    shelves to high-end units. Reducing the retention times for backup data can also help. When
    files are deleted from outside of the /ddvar space, filesys clean will have to be done before
    the space is recovered.

    Parsed from file DATA-DOMAIN-MIB.mib
    Module: DATA-DOMAIN-MIB

    Information by oid_info

    Vendor: Data Domain, Inc
    Module: DATA-DOMAIN-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    fileSpaceWarningAlarm NOTIFICATION-TYPE OBJECTS { fileSystemResourceIndex } STATUS current DESCRIPTION "Meaning: A File System Resource space is 90% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered." ::= { dataDomainMibNotifications 9 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.19746)

    Haile J. Mitchell

    Brothers (18)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.19746.2.1 powerSupplyFailedAlarm 0 0 Meaning: Power Supply failed
    What to do: replace the power supply
    1.3.6.1.4.1.19746.2.2 systemOverheatWarningAlarm 0 0 Meaning: the temperature reading of one of the thermometers in the Chassis has exceeded
    the 'warning' temperature level. If it…
    1.3.6.1.4.1.19746.2.3 systemOverheatAlertAlarm 0 0 Meaning: the temperature reading of one of the thermometers in the Chassis is more than
    halfway between the 'warning' and 'shutd…
    1.3.6.1.4.1.19746.2.4 systemOverheatShutdowntAlarm 0 0 Meaning: the temperature reading of one of the thermometers in the Chassis has reached
    or exceeded the 'shutdown' temperature le…
    1.3.6.1.4.1.19746.2.5 fanModuleFailedAlarm 0 0 Meaning: a Fan Module in the enclosure has failed. The index of the fan is given
    as the index of the alarm. This same index ca…
    1.3.6.1.4.1.19746.2.6 nvramFailingAlarm 0 0 Meaning: The system has detected that the NVRAM is potentially failing. There has
    been an excessive amount of PCI or Memory err…
    1.3.6.1.4.1.19746.2.7 fileSystemFailedAlarm 0 0 Meaning: The File System process on the DDR has had a serious problem and has had
    to restart.
    What to do: check the system logs f…
    1.3.6.1.4.1.19746.2.8 fileSpaceMaintenanceAlarm 0 0 Meaning: DDVAR File System Resource Space is running low for system maintenance activities. The
    system may not have enough spac…
    1.3.6.1.4.1.19746.2.10 fileSpaceSevereAlarm 0 0 Meaning: A File System Resource space is 95% utilized. The index value of the alarm indicates
    the file system index that may be…
    1.3.6.1.4.1.19746.2.11 fileSpaceCriticalAlarm 0 0 Meaning: A File System Resource space is 100% utilized. The index value of the alarm indicates
    the file system index that may b…
    1.3.6.1.4.1.19746.2.12 diskFailingAlarm 0 0 Meaning: some problem has been detected about the indicated disk. The index value
    of the alarm indicates the disk index that ma…
    1.3.6.1.4.1.19746.2.13 diskFailedAlarm 0 0 Meaning: some problem has been detected about the indicated disk. The index value
    of the alarm indicates the disk index that ma…
    1.3.6.1.4.1.19746.2.14 diskOverheatWarningAlarm 0 0 Meaning: the temperature reading of the indicated disk has exceeded the 'warning'
    temperature level. If it continues to rise, i…
    1.3.6.1.4.1.19746.2.15 diskOverheatAlertAlarm 0 0 Meaning: the temperature reading of the indicated disk is more than halfway between
    the 'warning' and 'shutdown' temperature lev…
    1.3.6.1.4.1.19746.2.16 diskOverheatShutdowntAlarm 0 0 Meaning: the temperature reading of the indicated disk has surpassed the 'shutdown'
    temperature level. The DDR will be shutdown.…
    1.3.6.1.4.1.19746.2.17 raidReconSevereAlarm 0 0 Meaning: Raid group reconstruction is currently active and has not completed after 71
    hours. Reconstruction occurs when the rai…
    1.3.6.1.4.1.19746.2.18 raidReconCriticalAlarm 0 0 Meaning: Raid group reconstruction is currently active and has not completed after 72
    hours. Reconstruction occurs when the rai…
    1.3.6.1.4.1.19746.2.19 raidReconCriticalShutdownAlarm 0 0 Meaning: Raid group reconstruction is currently active and has not completed after more
    than 72 hours. Reconstruction occurs wh…