Meaning: A File System Resource space is 90% utilized. The index value of the alarm indicates
the file system index that may be looked up in the fileSystem table 'fileSystemSpace'
for more information about the actual FS that is getting full.
What to do: Delete unneeded files, such as old log files, support bundles, core files,
upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding
shelves to high-end units. Reducing the retention times for backup data can also help. When
files are deleted from outside of the /ddvar space, filesys clean will have to be done before
the space is recovered.
Parsed from file DATA-DOMAIN-MIB.mib
Module: DATA-DOMAIN-MIB
Vendor: Data Domain, Inc
Module: DATA-DOMAIN-MIB
[Automatically extracted from oidview.com]
fileSpaceWarningAlarm NOTIFICATION-TYPE OBJECTS { fileSystemResourceIndex } STATUS current DESCRIPTION "Meaning: A File System Resource space is 90% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered." ::= { dataDomainMibNotifications 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.19746.2.1 | powerSupplyFailedAlarm | 0 | 0 | Meaning: Power Supply failed What to do: replace the power supply |
1.3.6.1.4.1.19746.2.2 | systemOverheatWarningAlarm | 0 | 0 | Meaning: the temperature reading of one of the thermometers in the Chassis has exceeded the 'warning' temperature level. If it… |
1.3.6.1.4.1.19746.2.3 | systemOverheatAlertAlarm | 0 | 0 | Meaning: the temperature reading of one of the thermometers in the Chassis is more than halfway between the 'warning' and 'shutd… |
1.3.6.1.4.1.19746.2.4 | systemOverheatShutdowntAlarm | 0 | 0 | Meaning: the temperature reading of one of the thermometers in the Chassis has reached or exceeded the 'shutdown' temperature le… |
1.3.6.1.4.1.19746.2.5 | fanModuleFailedAlarm | 0 | 0 | Meaning: a Fan Module in the enclosure has failed. The index of the fan is given as the index of the alarm. This same index ca… |
1.3.6.1.4.1.19746.2.6 | nvramFailingAlarm | 0 | 0 | Meaning: The system has detected that the NVRAM is potentially failing. There has been an excessive amount of PCI or Memory err… |
1.3.6.1.4.1.19746.2.7 | fileSystemFailedAlarm | 0 | 0 | Meaning: The File System process on the DDR has had a serious problem and has had to restart. What to do: check the system logs f… |
1.3.6.1.4.1.19746.2.8 | fileSpaceMaintenanceAlarm | 0 | 0 | Meaning: DDVAR File System Resource Space is running low for system maintenance activities. The system may not have enough spac… |
1.3.6.1.4.1.19746.2.10 | fileSpaceSevereAlarm | 0 | 0 | Meaning: A File System Resource space is 95% utilized. The index value of the alarm indicates the file system index that may be… |
1.3.6.1.4.1.19746.2.11 | fileSpaceCriticalAlarm | 0 | 0 | Meaning: A File System Resource space is 100% utilized. The index value of the alarm indicates the file system index that may b… |
1.3.6.1.4.1.19746.2.12 | diskFailingAlarm | 0 | 0 | Meaning: some problem has been detected about the indicated disk. The index value of the alarm indicates the disk index that ma… |
1.3.6.1.4.1.19746.2.13 | diskFailedAlarm | 0 | 0 | Meaning: some problem has been detected about the indicated disk. The index value of the alarm indicates the disk index that ma… |
1.3.6.1.4.1.19746.2.14 | diskOverheatWarningAlarm | 0 | 0 | Meaning: the temperature reading of the indicated disk has exceeded the 'warning' temperature level. If it continues to rise, i… |
1.3.6.1.4.1.19746.2.15 | diskOverheatAlertAlarm | 0 | 0 | Meaning: the temperature reading of the indicated disk is more than halfway between the 'warning' and 'shutdown' temperature lev… |
1.3.6.1.4.1.19746.2.16 | diskOverheatShutdowntAlarm | 0 | 0 | Meaning: the temperature reading of the indicated disk has surpassed the 'shutdown' temperature level. The DDR will be shutdown.… |
1.3.6.1.4.1.19746.2.17 | raidReconSevereAlarm | 0 | 0 | Meaning: Raid group reconstruction is currently active and has not completed after 71 hours. Reconstruction occurs when the rai… |
1.3.6.1.4.1.19746.2.18 | raidReconCriticalAlarm | 0 | 0 | Meaning: Raid group reconstruction is currently active and has not completed after 72 hours. Reconstruction occurs when the rai… |
1.3.6.1.4.1.19746.2.19 | raidReconCriticalShutdownAlarm | 0 | 0 | Meaning: Raid group reconstruction is currently active and has not completed after more than 72 hours. Reconstruction occurs wh… |