Status in source: current.
Names: h3cDot3Oam2UniqueEventNotificationRx
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"h3cDot3Oam2UniqueEventNotificationRx",
"OBJECT-TYPE",
"SYNTAX",
"Counter64",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"A count of the number of unique Event OAMPDUs received on this interface. Event notification OAMPDUs may be sent in duplicate to increase the probability of being successfully received, given the possiblity that a frame may be lost in transit. An Event Notification OAMPDU is indicated by a valid frame with (1) a destination MAC address that equals the reserved MAC address for Slow Protocols (see 43B of [802.3ah]), (2) a lengthOrType field that equals the reserved type for Slow Protocols, (3) a Slow Protocols subtype that equals the subtype reserved for OAM, and (4) an OAMPDU code that equals the OAM Event code. An Event Notification OAMPDU is uniquely identified by its Sequence Number field. Discontinuities of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of the ifCounterDiscontinuityTime. This object is similar to h3cDot3OamUniqueEventNotificationRx.\"",
"REFERENCE",
"\"[802.3ah], 30.3.6.1.24.\"",
"::=",
"{",
"h3cDot3OamStats2Entry",
"4",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Counter64"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A count of the number of unique Event OAMPDUs received on this interface. Event notification OAMPDUs may be sent in duplicate to increase the probability of being successfully received, given the possiblity that a frame may be lost in transit. An Event Notification OAMPDU is indicated by a valid frame with (1) a destination MAC address that equals the reserved MAC address for Slow Protocols (see 43B of [802.3ah]), (2) a lengthOrType field that equals the reserved type for Slow Protocols, (3) a Slow Protocols subtype that equals the subtype reserved for OAM, and (4) an OAMPDU code that equals the OAM Event code. An Event Notification OAMPDU is uniquely identified by its Sequence Number field. Discontinuities of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of the ifCounterDiscontinuityTime. This object is similar to h3cDot3OamUniqueEventNotificationRx."
],
[
"REFERENCE",
"[802.3ah], 30.3.6.1.24."
],
null,
null,
null
]
}
- H3C and HH3C MIB copies (Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
H3C and HH3C support.
Module: H3C-EFM-COMMON-MIB
See published definition above
Module imports
{'IF-MIB': ['ifIndex'], 'HCNUM-TC': ['CounterBasedGauge64'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'MacAddress', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'Unsigned32', 'Integer32', 'NOTIFICATION-TYPE', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'HUAWEI-3COM-OID-MIB': ['h3cEpon']}
· Download H3C-EFM-COMMON-MIB
Related source files and packages: