Status in source: current.
Names: optixRtnIFATPCLowThreshold
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"optixRtnIFATPCLowThreshold",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates the ATPC adjustment lower threshold. When the RSL is less than the lower threshold, the transmitter automatically adjusts its transmit power. Signed int type Value range: -900.0 to -250.0 Unit: 0.1 dBm\"",
"DEFVAL",
"{",
"-",
"700",
"}",
"::=",
"{",
"optixRtnIFATPCParameterEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates the ATPC adjustment lower threshold. When the RSL is less than the lower threshold, the transmitter automatically adjusts its transmit power. Signed int type Value range: -900.0 to -250.0 Unit: 0.1 dBm"
],
null,
null,
null,
[
"DEFVAL",
-700
]
]
}
- Huawei MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Huawei support.
Module: OPTIX-RTN-ATPC-MGR-MIB
See published definition above
Module imports
{'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'OPTIX-OID-MIB': ['optixProvisionRtn'], 'OPTIX-RTN-GENNERAL-MIB': ['OPTIXRtnEnableStateType'], 'OPTIX-RTN-IFBOARD-ATTRIB-MIB': ['optixRtnBoardID', 'optixRtnSubCardID', 'optixRtnPortID']}
· Download OPTIX-RTN-ATPC-MGR-MIB
Related source files and packages: