Status in source: current.
Names: optixRtnCcicATPCAutoThEnable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"optixRtnCcicATPCAutoThEnable",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"{",
"disabled",
"(",
"0",
")",
",",
"enabled",
"(",
"1",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates the enable status of the ATPC automatic threshold configuration function in an CCIC protection group. The ATPC function enables the transmit power of a transmitter to automatically trace the change of the RSL at the receive end within the ATPC control range. The equipment automatically uses the preset ATPC upper and lower thresholds based on the working mode of the IF board. When the function is disabled, the manually set ATPC upper and lower thresholds are used. Values: 0: disabled 1: enabled.\"",
"::=",
"{",
"optixRtnCcicParaEntry",
"8",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Unsigned32",
[
"enumSpec",
[
[
"disabled",
0
],
[
"enabled",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates the enable status of the ATPC automatic threshold configuration function in an CCIC protection group. The ATPC function enables the transmit power of a transmitter to automatically trace the change of the RSL at the receive end within the ATPC control range. The equipment automatically uses the preset ATPC upper and lower thresholds based on the working mode of the IF board. When the function is disabled, the manually set ATPC upper and lower thresholds are used. Values: 0: disabled 1: enabled."
],
null,
null,
null,
null
]
}
- Huawei MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Huawei support.
Module: OPTIX-RTN-CCIC-MGR-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'OPTIX-OID-MIB': ['optixProvisionRtn'], 'OPTIX-RTN-IFBOARD-ATTRIB-MIB': ['optixRtnBoardID', 'optixRtnSubCardID', 'optixRtnPortID', 'optixRtnIFPortAcmBandWidth', 'optixRtnIFPortAcmModulationMode']}
Source data warning: The published MIB attaches named values to Unsigned32, outside the SMIv2 enumeration grammar. The original type, labels and numbers are preserved; no conversion to INTEGER is made.
· Download OPTIX-RTN-CCIC-MGR-MIB
Related source files and packages: