It is applicable to the cascade PLA management table and the cascade EPLA management table (containing only two members).
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1
It is applicable to the cascade PLA management table and the cascade EPLA management table (containing only two members).
Identification
{1 3 6 1 4 1 2011 2 25 4 40 5 10 210 1}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
optixRtnNbplaStateEntry OBJECT-TYPE
SYNTAX OptixRtnNbplaStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"It is applicable to the cascade PLA management table and the cascade EPLA management table (containing only two members)."
INDEX{ optixRtnCascadingPhyLagPGID }
::= { optixRtnNbplaStateTable 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
It is applicable to the cascade PLA management table and the cascade EPLA management table (containing only two members).
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: optixRtnNbplaStateEntry
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"optixRtnNbplaStateEntry",
"OBJECT-TYPE",
"SYNTAX",
"OptixRtnNbplaStateEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"It is applicable to the cascade PLA management table and the cascade EPLA management table (containing only two members).\"",
"INDEX",
"{",
"optixRtnCascadingPhyLagPGID",
"}",
"::=",
"{",
"optixRtnNbplaStateTable",
"1",
"}"
],
"syntax_tree": [
[
"row",
"OptixRtnNbplaStateEntry"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"It is applicable to the cascade PLA management table and the cascade EPLA management table (containing only two members)."
],
null,
null,
[
"INDEX",
[
[
0,
"optixRtnCascadingPhyLagPGID"
]
]
],
null
]
}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: OPTIX-RTN-IF-PROTECT-MGR-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'OPTIX-OID-MIB': ['optixProvisionRtn'], 'OPTIX-RTN-ODU-MGR-MIB': ['OPTIXRtnOduWorkStateType'], 'OPTIX-RTN-GENNERAL-MIB': ['OPTIXRtnEnableStateType', 'optixRtnIndex1', 'optixRtnIndex2', 'optixRtnIndex3', 'optixRtnIndex4', 'optixRtngroupIndex', 'optixRtnboardIndex', 'optixRtnsubboardIndex', 'optixRtnportIndex'], 'OPTIX-RTN-IFBOARD-ATTRIB-MIB': ['OPTIXRtnModulateModeType', 'OPTIXRtnBandWidthType', 'optixRtnBoardID', 'optixRtnSubCardID', 'optixRtnPortID']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.1 | optixRtnPLANEId | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.2 | optixRtnPLAMSBID | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.3 | optixRtnPLAMSSUBID | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.4 | optixRtnPLAMSPID | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.5 | optixRtnPLAHardState | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.6 | optixRtnPLALinkState | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.10.210.1.7 | optixRtnPLAMSState | 0 | 0 |