Indicates the WorkMode of a PLA protection group.
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2011.2.25.4.40.5.20.240.4
Indicates the WorkMode of a PLA protection group.
Identification
{1 3 6 1 4 1 2011 2 25 4 40 5 20 240 4}
| Value | Name |
|---|---|
| 0 | modeA |
| 1 | modeB |
| 2 | modeAAccess |
| 255 | unknown |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
optixRptRtnPLAPGWorkMode OBJECT-TYPE
SYNTAX Unsigned32
{
modeA(0),
modeB(1),
modeAAccess(2),
unknown(255)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Indicates the WorkMode of a PLA protection group."
::= { optixRptRtnPLAPGScheduleModeChangeEvent 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates the WorkMode of a PLA protection group.
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: optixRptRtnPLAPGWorkMode
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"optixRptRtnPLAPGWorkMode",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"{",
"modeA",
"(",
"0",
")",
",",
"modeB",
"(",
"1",
")",
",",
"modeAAccess",
"(",
"2",
")",
",",
"unknown",
"(",
"255",
")",
"}",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates the WorkMode of a PLA protection group.\"",
"::=",
"{",
"optixRptRtnPLAPGScheduleModeChangeEvent",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Unsigned32",
[
"enumSpec",
[
[
"modeA",
0
],
[
"modeB",
1
],
[
"modeAAccess",
2
],
[
"unknown",
255
]
]
]
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates the WorkMode of a PLA protection group."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: OPTIX-RTN-IF-PROTECT-MGR-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'OPTIX-OID-MIB': ['optixProvisionRtn'], 'OPTIX-RTN-ODU-MGR-MIB': ['OPTIXRtnOduWorkStateType'], 'OPTIX-RTN-GENNERAL-MIB': ['OPTIXRtnEnableStateType', 'optixRtnIndex1', 'optixRtnIndex2', 'optixRtnIndex3', 'optixRtnIndex4', 'optixRtngroupIndex', 'optixRtnboardIndex', 'optixRtnsubboardIndex', 'optixRtnportIndex'], 'OPTIX-RTN-IFBOARD-ATTRIB-MIB': ['OPTIXRtnModulateModeType', 'OPTIXRtnBandWidthType', 'optixRtnBoardID', 'optixRtnSubCardID', 'optixRtnPortID']}Source data warning: The published MIB attaches named values to Unsigned32, outside the SMIv2 enumeration grammar. The original type, labels and numbers are preserved; no conversion to INTEGER is made.
· Download OPTIX-RTN-IF-PROTECT-MGR-MIBRelated source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.240.1 | optixRptRtnPLAPGId | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.240.2 | optixRptRtnPLAPGType | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.240.3 | optixRptRtnPLAPGCfgMode | 0 | 0 |