Indicates the current working subboard ID of a cascading IF 1+1 protection group on the equipment side.
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2011.2.25.4.40.5.20.30.4
Indicates the current working subboard ID of a cascading IF 1+1 protection group on the equipment side.
Identification
{1 3 6 1 4 1 2011 2 25 4 40 5 20 30 4}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
optixRptRtnC1j1PGWorkSubCardID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Indicates the current working subboard ID of a cascading IF 1+1 protection group on the equipment side."
::= { optixRptRtnCascading1j1PGEvent 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates the current working subboard ID of a cascading IF 1+1 protection group on the equipment side.
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: optixRptRtnC1j1PGWorkSubCardID
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"optixRptRtnC1j1PGWorkSubCardID",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates the current working subboard ID of a cascading IF 1+1 protection group on the equipment side.\"",
"::=",
"{",
"optixRptRtnCascading1j1PGEvent",
"4",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates the current working subboard ID of a cascading IF 1+1 protection group on the equipment side."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: OPTIX-RTN-IF-PROTECT-MGR-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'OPTIX-OID-MIB': ['optixProvisionRtn'], 'OPTIX-RTN-ODU-MGR-MIB': ['OPTIXRtnOduWorkStateType'], 'OPTIX-RTN-GENNERAL-MIB': ['OPTIXRtnEnableStateType', 'optixRtnIndex1', 'optixRtnIndex2', 'optixRtnIndex3', 'optixRtnIndex4', 'optixRtngroupIndex', 'optixRtnboardIndex', 'optixRtnsubboardIndex', 'optixRtnportIndex'], 'OPTIX-RTN-IFBOARD-ATTRIB-MIB': ['OPTIXRtnModulateModeType', 'OPTIXRtnBandWidthType', 'optixRtnBoardID', 'optixRtnSubCardID', 'optixRtnPortID']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.1 | optixRptRtnC1j1PGID | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.2 | optixRptRtnC1j1PGWorkNEID | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.3 | optixRptRtnC1j1PGWorkBoardID | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.5 | optixRptRtnC1j1PGWorkPortID | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.6 | optixRptRtnC1j1PGCurrWorkChannel | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.7 | optixRptRtnC1j1PGWorkBoardState | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.8 | optixRptRtnC1j1PGProtectBoardState | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.30.9 | optixRptRtnC1j1PGSwtichRequest | 0 | 0 |