Indicates the port ID of the cascading unit 1. An invalid value of 255 is returned when the adjacency channel is faulty.
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2011.2.25.4.40.5.20.40.13
Indicates the port ID of the cascading unit 1. An invalid value of 255 is returned when the adjacency channel is faulty.
Identification
{1 3 6 1 4 1 2011 2 25 4 40 5 20 40 13}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
optixRptRtnCPLAPGPu1PortID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Indicates the port ID of the cascading unit 1. An invalid value of 255 is returned when the adjacency channel is faulty."
::= { optixRptRtnCascadingPLAPGEvent 13 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates the port ID of the cascading unit 1. An invalid value of 255 is returned when the adjacency channel is faulty.
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: optixRptRtnCPLAPGPu1PortID
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"optixRptRtnCPLAPGPu1PortID",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates the port ID of the cascading unit 1. An invalid value of 255 is returned when the adjacency channel is faulty.\"",
"::=",
"{",
"optixRptRtnCascadingPLAPGEvent",
"13",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates the port ID of the cascading unit 1. An invalid value of 255 is returned when the adjacency channel is faulty."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: OPTIX-RTN-IF-PROTECT-MGR-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'OPTIX-OID-MIB': ['optixProvisionRtn'], 'OPTIX-RTN-ODU-MGR-MIB': ['OPTIXRtnOduWorkStateType'], 'OPTIX-RTN-GENNERAL-MIB': ['OPTIXRtnEnableStateType', 'optixRtnIndex1', 'optixRtnIndex2', 'optixRtnIndex3', 'optixRtnIndex4', 'optixRtngroupIndex', 'optixRtnboardIndex', 'optixRtnsubboardIndex', 'optixRtnportIndex'], 'OPTIX-RTN-IFBOARD-ATTRIB-MIB': ['OPTIXRtnModulateModeType', 'OPTIXRtnBandWidthType', 'optixRtnBoardID', 'optixRtnSubCardID', 'optixRtnPortID']}Related source files and packages:
Registration