Indicates whether the current working board on the equipment board is a working or protection board. The values are as follows: 0-working 1-protection
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2011.2.25.4.40.5.20.41.5
Indicates whether the current working board on the equipment board is a working or protection board. The values are as follows: 0-working 1-protection
Identification
{1 3 6 1 4 1 2011 2 25 4 40 5 20 41 5}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
optixRtnNonCascade1J1DevWorkBoardProperty OBJECT-TYPE
SYNTAX OPTIXRtn1j1DevWorkBoardProperty
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Indicates whether the current working board on the equipment board is a working or protection board. The values are as follows:
0-working
1-protection"
::= { optixRtnNonCascade1J1SwitchEvent 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates whether the current working board on the equipment board is a working or protection board. The values are as follows: 0-working 1-protection
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: optixRtnNonCascade1J1DevWorkBoardProperty
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"optixRtnNonCascade1J1DevWorkBoardProperty",
"OBJECT-TYPE",
"SYNTAX",
"OPTIXRtn1j1DevWorkBoardProperty",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates whether the current working board on the equipment board is a working or protection board. The values are as follows: 0-working 1-protection\"",
"::=",
"{",
"optixRtnNonCascade1J1SwitchEvent",
"5",
"}"
],
"syntax_tree": [
[
"row",
"OPTIXRtn1j1DevWorkBoardProperty"
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates whether the current working board on the equipment board is a working or protection board. The values are as follows: 0-working 1-protection"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: OPTIX-RTN-IF-PROTECT-MGR-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'OPTIX-OID-MIB': ['optixProvisionRtn'], 'OPTIX-RTN-ODU-MGR-MIB': ['OPTIXRtnOduWorkStateType'], 'OPTIX-RTN-GENNERAL-MIB': ['OPTIXRtnEnableStateType', 'optixRtnIndex1', 'optixRtnIndex2', 'optixRtnIndex3', 'optixRtnIndex4', 'optixRtngroupIndex', 'optixRtnboardIndex', 'optixRtnsubboardIndex', 'optixRtnportIndex'], 'OPTIX-RTN-IFBOARD-ATTRIB-MIB': ['OPTIXRtnModulateModeType', 'OPTIXRtnBandWidthType', 'optixRtnBoardID', 'optixRtnSubCardID', 'optixRtnPortID']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.1 | optixRtnNonCascade1J1GPID | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.2 | optixRtnNonCascade1J1BoardID | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.3 | optixRtnNonCascade1J1SubCardID | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.4 | optixRtnNonCascade1J1PortID | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.6 | optixRtnNonCascade1J1WorkBoardDevState | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.7 | optixRtnNonCascade1J1ProtBoardDevState | 0 | 0 | |
| 1.3.6.1.4.1.2011.2.25.4.40.5.20.41.8 | optixRtnNonCascade1J1DevSwtichRequest | 0 | 0 |