The value starts from 0x0001. The test duration is measured in seconds in short-term tests and minutes in long-term tests and super-long-term tests.
Sources for this description
Huawei MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.2011.2.25.4.40.5.20.49.7
The value starts from 0x0001. The test duration is measured in seconds in short-term tests and minutes in long-term tests and super-long-term tests.
Identification
{1 3 6 1 4 1 2011 2 25 4 40 5 20 49 7}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
optixRtnE1PRBSTimeStamp OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value starts from 0x0001. The test duration is measured in seconds in short-term tests and minutes in long-term tests and super-long-term tests."
::= { optixRtnE1PRBSTestEvent 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The value starts from 0x0001. The test duration is measured in seconds in short-term tests and minutes in long-term tests and super-long-term tests.
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: optixRtnE1PRBSTimeStamp
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"optixRtnE1PRBSTimeStamp",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"The value starts from 0x0001. The test duration is measured in seconds in short-term tests and minutes in long-term tests and super-long-term tests.\"",
"::=",
"{",
"optixRtnE1PRBSTestEvent",
"7",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value starts from 0x0001. The test duration is measured in seconds in short-term tests and minutes in long-term tests and super-long-term tests."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Huawei support.
Module: OPTIX-RTN-IF-PROTECT-MGR-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus'], 'SNMPv2-SMI': ['Integer32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'OPTIX-OID-MIB': ['optixProvisionRtn'], 'OPTIX-RTN-ODU-MGR-MIB': ['OPTIXRtnOduWorkStateType'], 'OPTIX-RTN-GENNERAL-MIB': ['OPTIXRtnEnableStateType', 'optixRtnIndex1', 'optixRtnIndex2', 'optixRtnIndex3', 'optixRtnIndex4', 'optixRtngroupIndex', 'optixRtnboardIndex', 'optixRtnsubboardIndex', 'optixRtnportIndex'], 'OPTIX-RTN-IFBOARD-ATTRIB-MIB': ['OPTIXRtnModulateModeType', 'OPTIXRtnBandWidthType', 'optixRtnBoardID', 'optixRtnSubCardID', 'optixRtnPortID']}Related source files and packages:
Registration