Description 1
The index of the table, which is the index of interface.
Sources for this description
H3C and HH3C MIB copies (Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.2011.5.25.32.2.12.1.1
The index of the table, which is the index of interface.
Identification
{1 3 6 1 4 1 2011 5 25 32 2 12 1 1}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In HUAWEI-IF-QOS-MIB, the row index consists of these components in order:
qosCQRunInfoIfIndex (INTEGER): one numeric subidentifier for the non-negative value.qosCQRunInfoQueNum (INTEGER): one numeric subidentifier for the non-negative value.An instance has the form .1.3.6.1.4.1.2011.5.25.32.2.12.1.1.<qosCQRunInfoIfIndex>.<qosCQRunInfoQueNum>. Use values present on the device and permitted by its MIB. Other definitions can differ.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 3 distinct definitions; some records may not include a definition.
qosCQRunInfoIfIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the table, which is the index of interface."
::= { qosCQRunInfoEntry 1 }qosCQRunInfoIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of the table, which is the index of interface applying Custom Queuing strategy.
The interface identified by the value of this index is the same interface
as identified by the same value of ifIndex."
::= { qosCQRunInfoEntry 1 }qosCQRunInfoIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of the table, which is the index of interface applying Custom Queuing strategy.
The interface identified by the value of this index is the same interface
as identified by the same value of ifIndex."
::= { qosCQRunInfoEntry 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
The index of the table, which is the index of interface.
H3C and HH3C MIB copies (Observium Community)Netdisco MIB archive copies
Description 2
The index of the table, which is the index of interface applying Custom Queuing strategy. The interface identified by the value of this index is the same interface as identified by the same value of ifIndex.
Huawei MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: qosCQRunInfoIfIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"qosCQRunInfoIfIndex",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"The index of the table, which is the index of interface.\"",
"::=",
"{",
"qosCQRunInfoEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The index of the table, which is the index of interface."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. H3C and HH3C support.
Module: HUAWEI-IF-QOS-MIB
See published definition above
{'SNMPv2-TC': ['RowStatus'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Integer32', 'Counter32'], 'HUAWEI-3COM-OID-MIB': ['hwQoS']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: HUAWEI-IF-QOS-MIB
{'SNMPv2-TC': ['RowStatus'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Integer32', 'Counter32'], 'HUAWEI-3COM-OID-MIB': ['hwQoS']}Related source files and packages:
Status in source: mandatory.
Names: qosCQRunInfoIfIndex
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"qosCQRunInfoIfIndex",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The index of the table, which is the index of interface applying Custom Queuing strategy. The interface identified by the value of this index is the same interface as identified by the same value of ifIndex.\"",
"::=",
"{",
"qosCQRunInfoEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The index of the table, which is the index of interface applying Custom Queuing strategy. The interface identified by the value of this index is the same interface as identified by the same value of ifIndex."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. Huawei support.
Module: HUAWEI-IF-QOS-MIB
See published definition above
{'SNMPv2-TC': ['RowStatus'], 'HUAWEI-MIB': ['hwDatacomm'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Integer32', 'Counter32']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. Huawei support.
Module: HUAWEI-IF-QOS-MIB
See published definition above
{'SNMPv2-TC': ['RowStatus'], 'HUAWEI-MIB': ['hwDatacomm'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Integer32', 'Counter32']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.5.25.32.2.12.1.2 | qosCQRunInfoQueNum | 0 | 0 | |
| 1.3.6.1.4.1.2011.5.25.32.2.12.1.3 | qosCQRunInfoIfName | 0 | 0 | |
| 1.3.6.1.4.1.2011.5.25.32.2.12.1.4 | qosCQRunInfoQuePkt | 0 | 0 | |
| 1.3.6.1.4.1.2011.5.25.32.2.12.1.5 | qosCQRunInfoQueDiscard | 0 | 0 | |
| 1.3.6.1.4.1.2011.5.25.32.2.12.1.6 | qosCQRunInfoMaxQueLen | 0 | 0 |