Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwvdsl2SeltTestParamUnCalibEchoRespRealSegment2",
"OBJECT-TYPE",
"SYNTAX",
"OCTET",
"STRING",
"(",
"SIZE",
"(",
"0",
".",
".",
"8192",
")",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1)*UER_G*Df is the highest frequency supported by the SELT-PMD functionality. The UER granularity parameter, UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be set to 2. The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as 32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as: UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1. NOTE - This data format supports an UER(f) granularity of 2^(-31) and an UER(f) dynamic range of approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements. An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no measurement could be done for this subcarrier either because it is not supported by the SELT-PMD function, or that the value is out of range to be represented. \"",
"::=",
"{",
"vdsl2SeltTestEntry",
"65540",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"OCTET STRING",
[
"octetStringSubType",
[
[
0,
8192
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1)*UER_G*Df is the highest frequency supported by the SELT-PMD functionality. The UER granularity parameter, UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be set to 2. The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as 32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as: UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1. NOTE - This data format supports an UER(f) granularity of 2^(-31) and an UER(f) dynamic range of approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements. An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no measurement could be done for this subcarrier either because it is not supported by the SELT-PMD function, or that the value is out of range to be represented."
],
null,
null,
null,
null
]
}