Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwVOPUPBOConfProfUpboKLREFUs3",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
"|",
"18",
".",
".",
"635",
")",
"UNITS",
[
"literal",
"22302e3120644222"
],
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"This parameter defines the UPBO reference electrical length used to compute the upstream power back-off for the upstream band US3, for the optional Equalized FEXT UPBO method. The value ranges from 1.8 to 63.5 dB in steps of 0.1 dB with special value 0. The use of the special value 0 is described in 7.2.1.3.2/G.993.2. Unit: 0.1 dB. \"",
"REFERENCE",
"\"ITU-T G.997.1, paragraph #7.3.1.2.14 a.4 (UPBOKLREF-pb)\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"hwVOPUPBOConfProfEntry",
"18",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0
],
[
18,
635
]
]
]
],
[
"UNITS",
"0.1 dB"
],
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This parameter defines the UPBO reference electrical length used to compute the upstream power back-off for the upstream band US3, for the optional Equalized FEXT UPBO method. The value ranges from 1.8 to 63.5 dB in steps of 0.1 dB with special value 0. The use of the special value 0 is described in 7.2.1.3.2/G.993.2. Unit: 0.1 dB."
],
[
"REFERENCE",
"ITU-T G.997.1, paragraph #7.3.1.2.14 a.4 (UPBOKLREF-pb)"
],
null,
null,
[
"DEFVAL",
0
]
]
}