Status in source: current.
Names: hwVOPUPBOConfProfUpboElmt
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hwVOPUPBOConfProfUpboElmt",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"15",
")",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"This parameter defines the UPBO electrical length minimum threshold percentile in percent used in the Alternative Electrical Length Estimation method (ELE-M1) in clause 7.2.1.3.2.2/G.993.2. It is set by network management via the CO-MIB. The parameter ranges from 0 to 15 percent in steps of 1 percent. This value is communicated to the VTU-R via G.994.1 at start-up. \"",
"REFERENCE",
"\"ITU-T G.997.1, paragraph 7.3.1.2.14\"",
"DEFVAL",
"{",
"10",
"}",
"::=",
"{",
"hwVOPUPBOConfProfEntry",
"21",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
15
]
]
]
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This parameter defines the UPBO electrical length minimum threshold percentile in percent used in the Alternative Electrical Length Estimation method (ELE-M1) in clause 7.2.1.3.2.2/G.993.2. It is set by network management via the CO-MIB. The parameter ranges from 0 to 15 percent in steps of 1 percent. This value is communicated to the VTU-R via G.994.1 at start-up."
],
[
"REFERENCE",
"ITU-T G.997.1, paragraph 7.3.1.2.14"
],
null,
null,
[
"DEFVAL",
10
]
]
}