Enabled setting to send an email alert when temperature sensor 1 thresholds are breached.
Parsed from file EATON-EPDU-PU-SW-MIB.txt
Company: eaton
Module: EATON-EPDU-PU-SW-MIB
tempSensor1Alert OBJECT-TYPE SYNTAX INTEGER { disabled (0), sendAlert (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enabled setting to send an email alert when temperature sensor 1 thresholds are breached." ::= { logManagerConfig 16 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.20677.2.3.1 | mailServerIPAddress | 0 | 0 | IP address of mail server for sending logs and alerts. |
1.3.6.1.4.1.20677.2.3.2 | sendLogFrom | 0 | 0 | Email address ([email protected] format) to be used as the from address for logs and alerts. |
1.3.6.1.4.1.20677.2.3.3 | sendLogToUser1Address | 0 | 0 | Email address to which to send unit logs. |
1.3.6.1.4.1.20677.2.3.4 | sendLogToUser2Address | 0 | 0 | Second email address to which to send unit logs. |
1.3.6.1.4.1.20677.2.3.5 | sendAlertsToUser1Address | 0 | 0 | Email address to which to send unit alerts. |
1.3.6.1.4.1.20677.2.3.6 | sendAlertsToUser2Address | 0 | 0 | Second email address to which to send unit alerts. |
1.3.6.1.4.1.20677.2.3.7 | sendLogFrequency | 0 | 0 | Frequency with which to send logs via email. |
1.3.6.1.4.1.20677.2.3.8 | sendLogTime | 0 | 0 | Time of day to send logs via email. Not applicable if sendLogFrequency is set to whenFull or never. |
1.3.6.1.4.1.20677.2.3.9 | userLogInLogOut | 0 | 0 | Enabled setting to log or send an alert when a user logs in or logs out of the serial, telnet, or web interfaces. |
1.3.6.1.4.1.20677.2.3.10 | userLogInLogOutFailed | 0 | 0 | Enabled setting to log or send an alert when a user attempts to log in but fails because of a username or password mismatch. |
1.3.6.1.4.1.20677.2.3.11 | outletActivity | 0 | 0 | Enabled setting to log or send an alert each time an outlet changes state. |
1.3.6.1.4.1.20677.2.3.12 | systemOnOff | 0 | 0 | Enabled setting to log or send an alert each time the unit powers up. |
1.3.6.1.4.1.20677.2.3.13 | outletSection1Alert | 0 | 0 | Enabled setting to send an email alert when section 1 thresholds are breached. |
1.3.6.1.4.1.20677.2.3.14 | outletSection2Alert | 0 | 0 | Enabled setting to send an email alert when section 2 thresholds are brached. |
1.3.6.1.4.1.20677.2.3.15 | outletSection3Alert | 0 | 0 | Enabled setting to send an email alert when section 3 thresholds are breached. |
1.3.6.1.4.1.20677.2.3.17 | tempSensor2Alert | 0 | 0 | Enabled setting to send an email alert when temperature sensor 2 thresholds are breached. |
1.3.6.1.4.1.20677.2.3.18 | humSensor1Alert | 0 | 0 | Enabled setting to send an email alert when humidity sensor thresholds are breached. |
1.3.6.1.4.1.20677.2.3.19 | contactClosure1Alert | 0 | 0 | Enabled setting to send an email alert when contact sensor 1 changes state. |
1.3.6.1.4.1.20677.2.3.20 | contactClosure2Alert | 0 | 0 | Enabled setting to send an email alert when contact sensor 2 changes state. |
1.3.6.1.4.1.20677.2.3.21 | contactClosure3Alert | 0 | 0 | Enabled setting to send an email alert when contact sensor 3 changes state. |