Slot Id of the chassis for which the configuration entry applies.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Belden, GarrettCom and Hirschmann IT official standalone MIBs
OID reference
1.3.6.1.4.1.2076.81.100.5.1.1
Slot Id of the chassis for which the configuration entry applies.
Identification
{1 3 6 1 4 1 2076 81 100 5 1 1}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In ARICENT-CHASSIS-MIB, the row index mbsmLCConfigSlotId is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.2076.81.100.5.1.1.<mbsmLCConfigSlotId>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
mbsmLCConfigSlotId OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Slot Id of the chassis for which the configuration
entry applies."
::= { mbsmLCConfigEntry 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Slot Id of the chassis for which the configuration entry applies.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Belden, GarrettCom and Hirschmann IT official standalone MIBs
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: mbsmLCConfigSlotId
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mbsmLCConfigSlotId",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"2147483647",
")",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"Slot Id of the chassis for which the configuration entry applies.\"",
"::=",
"{",
"mbsmLCConfigEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
2147483647
]
]
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Slot Id of the chassis for which the configuration entry applies."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: ARICENT-CHASSIS-MIB
See published definition above
{'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'Gauge32', 'NOTIFICATION-TYPE'], 'IANAifType-MIB': ['IANAifType']}Related source files and packages:
Module: ARICENT-CHASSIS-MIB
{'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'NOTIFICATION-TYPE'], 'IANAifType-MIB': ['IANAifType']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2076.81.100.5.1.2 | mbsmLCConfigCardName | 0 | 0 | |
| 1.3.6.1.4.1.2076.81.100.5.1.3 | mbsmLCConfigStatus | 0 | 0 |