Sensor reading table. Use port/addr as indexes to access sensor readings.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.21317.1.3.2.3.3.1.4
Sensor reading table. Use port/addr as indexes to access sensor readings.
Identification
{1 3 6 1 4 1 21317 1 3 2 3 3 1 4}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
sensorReadingTable OBJECT-TYPE
SYNTAX SEQUENCE OF SensorReadingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sensor reading table.
Use port/addr as indexes to access sensor readings."
::= { sensor 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Sensor reading table. Use port/addr as indexes to access sensor readings.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: sensorReadingTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sensorReadingTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"SensorReadingEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"Sensor reading table. Use port/addr as indexes to access sensor readings.\"",
"::=",
"{",
"sensor",
"4",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"SensorReadingEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Sensor reading table. Use port/addr as indexes to access sensor readings."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: ATEN-PE2-CFG
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber'], 'ATEN-PRODUCTS-MIB': ['poweroverip'], 'SNMP-USER-BASED-SM-MIB': ['KeyChange']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21317.1.3.2.3.3.1.4.1 | sensorReadingEntry | 3 | 3 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21317.1.3.2.3.3.1.3 | sensorConfigTable | 1 | 9 |