Description 1
Alarm1 on CO2 level; none, active
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.22626.1.2.1.13
Alarm1 on CO2 level; none, active
Identification
{1 3 6 1 4 1 22626 1 2 1 13}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.22626.1.2.1.13.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 3 distinct definitions; some records may not include a definition.
co2Alarm1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Alarm1 on CO2 level; none, active"
::= { values 13 }tempMin OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Minimal temperature"
::= { values 13 }pressAlarm1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Alarm1 on Atmospheric pressure; none, active"
::= { values 13 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Alarm1 on CO2 level; none, active
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Minimal temperature
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 3
Alarm1 on Atmospheric pressure; none, active
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: mandatory.
Names: co2Alarm1
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"co2Alarm1",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"(",
"SIZE",
"(",
"0",
".",
".",
"8",
")",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Alarm1 on CO2 level; none, active\"",
"::=",
"{",
"values",
"13",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DisplayString",
[
"octetStringSubType",
[
[
0,
8
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Alarm1 on CO2 level; none, active"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: H5521-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Vendor MIB copy from the Observium Community archive.
Module: H6521-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Status in source: mandatory.
Names: tempMin
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tempMin",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"(",
"SIZE",
"(",
"0",
".",
".",
"8",
")",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Minimal temperature\"",
"::=",
"{",
"values",
"13",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DisplayString",
[
"octetStringSubType",
[
[
0,
8
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Minimal temperature"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: T3610-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: T4511-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Status in source: mandatory.
Names: pressAlarm1
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pressAlarm1",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"(",
"SIZE",
"(",
"0",
".",
".",
"8",
")",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Alarm1 on Atmospheric pressure; none, active\"",
"::=",
"{",
"values",
"13",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DisplayString",
[
"octetStringSubType",
[
[
0,
8
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Alarm1 on Atmospheric pressure; none, active"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: H7530-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Vendor MIB copy from the Observium Community archive.
Module: H7531-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Registration