Description 1
Minimal atmospheric pressure
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.22626.1.2.1.16
Minimal atmospheric pressure
Identification
{1 3 6 1 4 1 22626 1 2 1 16}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.22626.1.2.1.16.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 3 distinct definitions; some records may not include a definition.
pressMin OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Minimal atmospheric pressure"
::= { values 16 }compValAlarm2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Alarm2 on Computed value; none, active"
::= { values 16 }co2Min OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Minimal CO2 level"
::= { values 16 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Minimal atmospheric pressure
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Alarm2 on Computed value; none, active
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 3
Minimal CO2 level
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: mandatory.
Names: pressMin
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"pressMin",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"(",
"SIZE",
"(",
"0",
".",
".",
"8",
")",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Minimal atmospheric pressure\"",
"::=",
"{",
"values",
"16",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DisplayString",
[
"octetStringSubType",
[
[
0,
8
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Minimal atmospheric pressure"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: T2514-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Vendor MIB copy from the Observium Community archive.
Module: T7611-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Status in source: mandatory.
Names: compValAlarm2
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"compValAlarm2",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"(",
"SIZE",
"(",
"0",
".",
".",
"8",
")",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Alarm2 on Computed value; none, active\"",
"::=",
"{",
"values",
"16",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DisplayString",
[
"octetStringSubType",
[
[
0,
8
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Alarm2 on Computed value; none, active"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: H3531-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Vendor MIB copy from the Observium Community archive.
Module: H6521-MIB
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Status in source: mandatory.
Names: co2Min
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"co2Min",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"(",
"SIZE",
"(",
"0",
".",
".",
"8",
")",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Minimal CO2 level\"",
"::=",
"{",
"values",
"16",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"DisplayString",
[
"octetStringSubType",
[
[
0,
8
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Minimal CO2 level"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: T5545-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises']}Vendor MIB copy from the Observium Community archive.
Module: T6541-MIB