Status in source: unspecified.
Technical details
{
"smi_kind": "TRAP-TYPE",
"definition": [
"sCellEventTrap_4_a",
"TRAP-TYPE",
"ENTERPRISE",
"compaq",
"VARIABLES",
"{",
"scellNameDateTime",
",",
"scellSWComponent",
",",
"scellECode",
",",
"scellCAC",
",",
"scellEIP",
"}",
"DESCRIPTION",
"\"Severity: Normal -- informational in nature. The Storage System Termination Event Log validation failed. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the state of the Storage System Termination Event Log at the time of the failure. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: <UL><LI>F = Control block read failed during maintenance verification. <LI>10= Control block write failed during maintenance verification. <LI>11= Event data block write failed during maintenance update. <LI>12= Control block write failed during maintenance completion. <LI>13= Storage System Termination Event Log related send was unsuccessful or the master found that the Storage System Termination Event Log is inaccessible. <LI>16= Event data block read failed during retrieval request. <LI>17= The log was destroyed and prepared for re-initialization. </UL><P> Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined.\"",
"::=",
"13601034"
],
"syntax_tree": [
[
"objectIdentifier",
[
"compaq"
]
],
[
"VarTypes",
[
"scellNameDateTime",
"scellSWComponent",
"scellECode",
"scellCAC",
"scellEIP"
]
],
[
"DESCRIPTION",
"Severity: Normal -- informational in nature. The Storage System Termination Event Log validation failed. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the state of the Storage System Termination Event Log at the time of the failure. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: <UL><LI>F = Control block read failed during maintenance verification. <LI>10= Control block write failed during maintenance verification. <LI>11= Event data block write failed during maintenance update. <LI>12= Control block write failed during maintenance completion. <LI>13= Storage System Termination Event Log related send was unsuccessful or the master found that the Storage System Termination Event Log is inaccessible. <LI>16= Event data block read failed during retrieval request. <LI>17= The log was destroyed and prepared for re-initialization. </UL><P> Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined."
],
null
]
}