Reference record for OID 1.3.6.1.4.1.232.0.13601579

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13601579
Node names
  • sCellEventTrap_6_2b
  • sCellEventTrap-06-2b
Numeric OID
1.3.6.1.4.1.232.0.13601579
URN notation
urn:oid:1.3.6.1.4.1.232.0.13601579
ASN.1 notation

{1 3 6 1 4 1 232 0 13601579}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13601579
  • /ISO/Identified-Organization/6/1/4/1/232/0/13601579
  • /ISO/3/6/1/4/1/232/0/13601579
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-06-2b
  • Additional combinations skipped.

Descriptions

sCellEventTrap_6_2b — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case.

sCellEventTrap-06-2b — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable.

Source records

sCellEventTrap_6_2b

Status in source: unspecified.

Names: sCellEventTrap_6_2b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_6_2b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case.\"",
    "::=",
    "13601579"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_2b.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_2b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-06-2b

Status in source: unspecified.

Names: sCellEventTrap-06-2b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-2b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable.\"",
    "::=",
    "13601579"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-06-2b.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-06-2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
               --#TYPE      "StorageCell Event 062b4004"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-06-2b.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB

    Related source files and packages:


    Source location: CPQHSV-MIB::sCellEventTrap-06-2b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.13004 cpqRsOnlineCableFailure00
1.3.6.1.4.1.232.0.13005 cpqRsFailoverFailed00
1.3.6.1.4.1.232.0.14001 cpqIdeDriveDegraded00
1.3.6.1.4.1.232.0.14002 cpqIdeDriveOk00
1.3.6.1.4.1.232.0.14003 cpqIdeDriveUltraAtaDegraded00
1.3.6.1.4.1.232.0.14004 cpqIdeAtaDiskStatusChange00
1.3.6.1.4.1.232.0.14005 cpqIdeLogicalDriveStatusChange00
1.3.6.1.4.1.232.0.14006 cpqIdeAtaDiskSSDWearStatusChange00
1.3.6.1.4.1.232.0.14007 cpqIdeAtaSecureEraseFailed00
1.3.6.1.4.1.232.0.14008 cpqIdeAtaDiskStatusChange200
1.3.6.1.4.1.232.0.14009 cpqIdeAtaDiskSSDWearStatusChange200
1.3.6.1.4.1.232.0.15001 cpqClusterDegraded00
1.3.6.1.4.1.232.0.15002 cpqClusterFailed00
1.3.6.1.4.1.232.0.15003 cpqClusterNodeDegraded00
1.3.6.1.4.1.232.0.15004 cpqClusterNodeFailed00
1.3.6.1.4.1.232.0.15005 cpqClusterResourceDegraded00
1.3.6.1.4.1.232.0.15006 cpqClusterResourceFailed00
1.3.6.1.4.1.232.0.15007 cpqClusterNetworkDegraded00
1.3.6.1.4.1.232.0.15008 cpqClusterNetworkFailed00
1.3.6.1.4.1.232.0.16001 cpqFcaLogDrvStatusChange00
1.3.6.1.4.1.232.0.16002 cpqFcaSpareStatusChange00
1.3.6.1.4.1.232.0.16003 cpqFcaPhyDrvStatusChange00
1.3.6.1.4.1.232.0.16004 cpqFcaAccelStatusChange00
1.3.6.1.4.1.232.0.16005 cpqFcaAccelBadDataTrap00
1.3.6.1.4.1.232.0.16006 cpqFcaAccelBatteryFailed00
1.3.6.1.4.1.232.0.16007 cpqFcaCntlrStatusChange00
1.3.6.1.4.1.232.0.16008 cpqFcTapeCntlrStatusChange00
1.3.6.1.4.1.232.0.16009 cpqFcTapeLibraryStatusChange00
1.3.6.1.4.1.232.0.16010 cpqFcTapeLibraryDoorStatusChange00
1.3.6.1.4.1.232.0.16011 cpqFcTapeDriveStatusChange00
1.3.6.1.4.1.232.0.16012 cpqFcTapeDriveCleaningRequired00
1.3.6.1.4.1.232.0.16013 cpqFcTapeDriveCleanTapeReplace00
1.3.6.1.4.1.232.0.16014 cpqFcaCntlrActive00
1.3.6.1.4.1.232.0.16015 cpqFcaHostCntlrStatusChange00
1.3.6.1.4.1.232.0.16016 cpqFca2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.16017 cpqFca2AccelStatusChange00
1.3.6.1.4.1.232.0.16018 cpqFca2AccelBadDataTrap00
1.3.6.1.4.1.232.0.16019 cpqFca2AccelBatteryFailed00
1.3.6.1.4.1.232.0.16020 cpqFca2CntlrStatusChange00
1.3.6.1.4.1.232.0.16021 cpqFca2HostCntlrStatusChange00
1.3.6.1.4.1.232.0.16022 cpqExtArrayLogDrvStatusChange00
1.3.6.1.4.1.232.0.16023 cpqExtTapeDriveStatusChange00
1.3.6.1.4.1.232.0.16024 cpqExtTapeDriveCleaningRequired00
1.3.6.1.4.1.232.0.16025 cpqExtTapeDriveCleanTapeReplace00
1.3.6.1.4.1.232.0.16026 cpqExtTapeLibraryStatusChange00
1.3.6.1.4.1.232.0.16027 cpqExtTapeLibraryDoorStatusChange00
1.3.6.1.4.1.232.0.16028 cpqFca3HostCntlrStatusChange00
1.3.6.1.4.1.232.0.18001 cpqNicConnectivityRestored00
1.3.6.1.4.1.232.0.18002 cpqNicConnectivityLost00
1.3.6.1.4.1.232.0.18003 cpqNicRedundancyIncreased00