Reference record for OID 1.3.6.1.4.1.232.0.13601579

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13601579
Node names
  • sCellEventTrap_6_2b
  • sCellEventTrap-06-2b
Numeric OID
1.3.6.1.4.1.232.0.13601579
URN notation
urn:oid:1.3.6.1.4.1.232.0.13601579
ASN.1 notation

{1 3 6 1 4 1 232 0 13601579}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-06-2b(13601579)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-06-2b(13601579)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13601579
  • /ISO/Identified-Organization/6/1/4/1/232/0/13601579
  • /ISO/3/6/1/4/1/232/0/13601579
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-06-2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_6_2b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-06-2b
  • Additional combinations skipped.

Descriptions

sCellEventTrap_6_2b — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case.

sCellEventTrap-06-2b — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable.

Source records

sCellEventTrap_6_2b

Status in source: unspecified.

Names: sCellEventTrap_6_2b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_6_2b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case.\"",
    "::=",
    "13601579"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_2b.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_6_2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_6_2b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-06-2b

Status in source: unspecified.

Names: sCellEventTrap-06-2b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-06-2b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable.\"",
    "::=",
    "13601579"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-06-2b.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-06-2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
               --#TYPE      "StorageCell Event 062b4004"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-06-2b.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-06-2b TRAP-TYPE  -- CAC Code: 40
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13601579
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB

    Related source files and packages:


    Source location: CPQHSV-MIB::sCellEventTrap-06-2b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.18004 cpqNicRedundancyReduced00
1.3.6.1.4.1.232.0.18005 cpqNic2ConnectivityRestored00
1.3.6.1.4.1.232.0.18006 cpqNic2ConnectivityLost00
1.3.6.1.4.1.232.0.18007 cpqNic2RedundancyIncreased00
1.3.6.1.4.1.232.0.18008 cpqNic2RedundancyReduced00
1.3.6.1.4.1.232.0.18009 cpqNicVirusLikeActivityDetected00
1.3.6.1.4.1.232.0.18010 cpqNicVirusLikeActivityStopped00
1.3.6.1.4.1.232.0.18011 cpqNic3ConnectivityRestored00
1.3.6.1.4.1.232.0.18012 cpqNic3ConnectivityLost00
1.3.6.1.4.1.232.0.18013 cpqNic3RedundancyIncreased00
1.3.6.1.4.1.232.0.18014 cpqNic3RedundancyReduced00
1.3.6.1.4.1.232.0.18015 cpqNicAllLinksDown00
1.3.6.1.4.1.232.0.18016 cpqNicAllLinksDownRepaired00
1.3.6.1.4.1.232.0.18017 cpqNicFlexLomTrainingFailed00
1.3.6.1.4.1.232.0.19001 cpqOsCpuTimeDegraded00
1.3.6.1.4.1.232.0.19002 cpqOsCpuTimeFailed00
1.3.6.1.4.1.232.0.19003 cpqOsCacheCopyReadHitsDegraded00
1.3.6.1.4.1.232.0.19004 cpqOsCacheCopyReadHitsFailed00
1.3.6.1.4.1.232.0.19005 cpqOsPageFileUsageDegraded00
1.3.6.1.4.1.232.0.19006 cpqOsPageFileUsageFailed00
1.3.6.1.4.1.232.0.19007 cpqOsLogicalDiskBusyTimeDegraded00
1.3.6.1.4.1.232.0.19008 cpqOsLogicalDiskBusyTimeFailed00
1.3.6.1.4.1.232.0.22001 cpqRackNameChanged00
1.3.6.1.4.1.232.0.22002 cpqRackEnclosureNameChanged00
1.3.6.1.4.1.232.0.22003 cpqRackEnclosureRemoved00
1.3.6.1.4.1.232.0.22004 cpqRackEnclosureInserted00
1.3.6.1.4.1.232.0.22005 cpqRackEnclosureTempFailed00
1.3.6.1.4.1.232.0.22006 cpqRackEnclosureTempDegraded00
1.3.6.1.4.1.232.0.22007 cpqRackEnclosureTempOk00
1.3.6.1.4.1.232.0.22008 cpqRackEnclosureFanFailed00
1.3.6.1.4.1.232.0.22009 cpqRackEnclosureFanDegraded00
1.3.6.1.4.1.232.0.22010 cpqRackEnclosureFanOk00
1.3.6.1.4.1.232.0.22011 cpqRackEnclosureFanRemoved00
1.3.6.1.4.1.232.0.22012 cpqRackEnclosureFanInserted00
1.3.6.1.4.1.232.0.22013 cpqRackPowerSupplyFailed00
1.3.6.1.4.1.232.0.22014 cpqRackPowerSupplyDegraded00
1.3.6.1.4.1.232.0.22015 cpqRackPowerSupplyOk00
1.3.6.1.4.1.232.0.22016 cpqRackPowerSupplyRemoved00
1.3.6.1.4.1.232.0.22017 cpqRackPowerSupplyInserted00
1.3.6.1.4.1.232.0.22018 cpqRackPowerSubsystemNotRedundant00
1.3.6.1.4.1.232.0.22019 cpqRackPowerSubsystemLineVoltageProblem00
1.3.6.1.4.1.232.0.22020 cpqRackPowerSubsystemOverloadCondition00
1.3.6.1.4.1.232.0.22021 cpqRackPowerShedAutoShutdown00
1.3.6.1.4.1.232.0.22022 cpqRackServerPowerOnFailedNotRedundant00
1.3.6.1.4.1.232.0.22023 cpqRackServerPowerOnFailedNotEnoughPower00
1.3.6.1.4.1.232.0.22024 cpqRackServerPowerOnFailedEnclosureNotFound00
1.3.6.1.4.1.232.0.22025 cpqRackServerPowerOnFailedPowerChassisNotFound00
1.3.6.1.4.1.232.0.22026 cpqRackServerPowerOnManualOverride00
1.3.6.1.4.1.232.0.22027 cpqRackFuseOpen00
1.3.6.1.4.1.232.0.22028 cpqRackServerBladeRemoved00