Reference record for OID 1.3.6.1.4.1.232.0.13603419

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13603419
Node names
  • sCellEventTrap_d_5b
  • sCellEventTrap-0d-5b
Numeric OID
1.3.6.1.4.1.232.0.13603419
URN notation
urn:oid:1.3.6.1.4.1.232.0.13603419
ASN.1 notation

{1 3 6 1 4 1 232 0 13603419}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-5b(13603419)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-5b(13603419)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13603419
  • /ISO/Identified-Organization/6/1/4/1/232/0/13603419
  • /ISO/3/6/1/4/1/232/0/13603419
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-0d-5b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_d_5b
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-0d-5b
  • Additional combinations skipped.

Descriptions

sCellEventTrap-0d-5b — MIBdepot

Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure link modules.

sCellEventTrap-0d-5b — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements.

sCellEventTrap-0d-5b — HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C.

sCellEventTrap_d_5b — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 Exhaust <LI>2 = Power Supply 2 Exhaust <LI>3 = Drive Enclosure Environmental Monitoring Unit <LI>4 = Drive Bay 1 <LI>5 = Drive Bay 2 <LI>6 = Drive Bay 3 <LI>7 = Drive Bay 4 <LI>8 = Drive Bay 5 <LI>9 = Drive Bay 6 <LI>A = Drive Bay 7 <LI>B = Drive Bay 8 <LI>C = Drive Bay 9 <LI>D = Drive Bay 10 <LI>E = Drive Bay 11 <LI>F = Drive Bay 12 <LI>10 = Drive Bay 13 <LI>11 = Drive Bay 14 </UL><P> The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. <LI>3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. </UL><P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

Source records

sCellEventTrap-0d-5b

Status in source: unspecified.

Names: sCellEventTrap-0d-5b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure link modules.\"",
    "::=",
    "13603419"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure link modules."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure link modules."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

sCellEventTrap-0d-5b

Status in source: unspecified.

Names: sCellEventTrap-0d-5b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements.\"",
    "::=",
    "13603419"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements."
               --#TYPE      "StorageCell Event 0d5b8611"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB
    Source location: CPQHSV-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

sCellEventTrap-0d-5b

Status in source: unspecified.

Names: sCellEventTrap-0d-5b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C.\"",
    "::=",
    "13603419"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB
    Source location: CPQHSV340V11-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5b8606"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB
    Source location: CPQHSV300V11-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5b8606"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB
    Source location: CPQHSV360V11-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5b8606"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB
    Source location: CPQHSV450V11-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-0d-5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at warning level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5b8606"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB
    Source location: CPQHSV400V11-MIB::sCellEventTrap-0d-5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

sCellEventTrap_d_5b

Status in source: unspecified.

Names: sCellEventTrap_d_5b

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_d_5b",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 Exhaust <LI>2 = Power Supply 2 Exhaust <LI>3 = Drive Enclosure Environmental Monitoring Unit <LI>4 = Drive Bay 1 <LI>5 = Drive Bay 2 <LI>6 = Drive Bay 3 <LI>7 = Drive Bay 4 <LI>8 = Drive Bay 5 <LI>9 = Drive Bay 6 <LI>A = Drive Bay 7 <LI>B = Drive Bay 8 <LI>C = Drive Bay 9 <LI>D = Drive Bay 10 <LI>E = Drive Bay 11 <LI>F = Drive Bay 12 <LI>10 = Drive Bay 13 <LI>11 = Drive Bay 14 </UL><P> The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. <LI>3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. </UL><P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13603419"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 Exhaust <LI>2 = Power Supply 2 Exhaust <LI>3 = Drive Enclosure Environmental Monitoring Unit <LI>4 = Drive Bay 1 <LI>5 = Drive Bay 2 <LI>6 = Drive Bay 3 <LI>7 = Drive Bay 4 <LI>8 = Drive Bay 5 <LI>9 = Drive Bay 6 <LI>A = Drive Bay 7 <LI>B = Drive Bay 8 <LI>C = Drive Bay 9 <LI>D = Drive Bay 10 <LI>E = Drive Bay 11 <LI>F = Drive Bay 12 <LI>10 = Drive Bay 13 <LI>11 = Drive Bay 14 </UL><P> The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. <LI>3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. </UL><P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 Exhaust <LI>2 = Power Supply 2 Exhaust <LI>3 = Drive Enclosure Environmental Monitoring Unit <LI>4 = Drive Bay 1 <LI>5 = Drive Bay 2 <LI>6 = Drive Bay 3 <LI>7 = Drive Bay 4 <LI>8 = Drive Bay 5 <LI>9 = Drive Bay 6 <LI>A = Drive Bay 7 <LI>B = Drive Bay 8 <LI>C = Drive Bay 9 <LI>D = Drive Bay 10 <LI>E = Drive Bay 11 <LI>F = Drive Bay 12 <LI>10 = Drive Bay 13 <LI>11 = Drive Bay 14 </UL><P> The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. <LI>3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. </UL><P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_5b.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_5b TRAP-TYPE  -- CAC Code: 86
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 Exhaust <LI>2 = Power Supply 2 Exhaust <LI>3 = Drive Enclosure Environmental Monitoring Unit <LI>4 = Drive Bay 1 <LI>5 = Drive Bay 2 <LI>6 = Drive Bay 3 <LI>7 = Drive Bay 4 <LI>8 = Drive Bay 5 <LI>9 = Drive Bay 6 <LI>A = Drive Bay 7 <LI>B = Drive Bay 8 <LI>C = Drive Bay 9 <LI>D = Drive Bay 10 <LI>E = Drive Bay 11 <LI>F = Drive Bay 12 <LI>10 = Drive Bay 13 <LI>11 = Drive Bay 14 </UL><P> The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. <LI>3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. </UL><P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  MINOR
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603419
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_5b.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.5006 cpqScsi3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5007 cpqTape3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5008 cpqTape3PhyDrvCleaningRequired00
1.3.6.1.4.1.232.0.5009 cpqTape3PhyDrvCleanTapeReplace00
1.3.6.1.4.1.232.0.5010 cpqTape3LibraryFailed00
1.3.6.1.4.1.232.0.5011 cpqTape3LibraryOkay00
1.3.6.1.4.1.232.0.5012 cpqTape3LibraryDegraded00
1.3.6.1.4.1.232.0.5013 cpqTape3LibraryDoorOpen00
1.3.6.1.4.1.232.0.5014 cpqTape3LibraryDoorClosed00
1.3.6.1.4.1.232.0.5015 cpqScsiCdLibraryStatusChange00
1.3.6.1.4.1.232.0.5016 cpqTape4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5017 cpqScsi4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5018 cpqTapeLibraryStatusChange00
1.3.6.1.4.1.232.0.5019 cpqTape5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5020 cpqScsi5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5021 cpqScsi3LogDrvStatusChange00
1.3.6.1.4.1.232.0.5022 cpqSasPhyDrvStatusChange00
1.3.6.1.4.1.232.0.5023 cpqSasLogDrvStatusChange00
1.3.6.1.4.1.232.0.5025 cpqSas2TapeDrvStatusChange00
1.3.6.1.4.1.232.0.5026 cpqSasPhyDrvSSDWearStatusChange00
1.3.6.1.4.1.232.0.6001 cpqHe2CorrectableMemoryError00
1.3.6.1.4.1.232.0.6002 cpqHe2CorrectableMemoryLogDisabled00
1.3.6.1.4.1.232.0.6003 cpqHeThermalTempFailed00
1.3.6.1.4.1.232.0.6004 cpqHeThermalTempDegraded00
1.3.6.1.4.1.232.0.6005 cpqHeThermalTempOk00
1.3.6.1.4.1.232.0.6006 cpqHeThermalSystemFanFailed00
1.3.6.1.4.1.232.0.6007 cpqHeThermalSystemFanDegraded00
1.3.6.1.4.1.232.0.6008 cpqHeThermalSystemFanOk00
1.3.6.1.4.1.232.0.6009 cpqHeThermalCpuFanFailed00
1.3.6.1.4.1.232.0.6010 cpqHeThermalCpuFanOk00
1.3.6.1.4.1.232.0.6011 cpqHeAsrConfirmation00
1.3.6.1.4.1.232.0.6012 cpqHeThermalConfirmation00
1.3.6.1.4.1.232.0.6013 cpqHePostError00
1.3.6.1.4.1.232.0.6014 cpqHeFltTolPwrSupplyDegraded00
1.3.6.1.4.1.232.0.6015 cpqHe3CorrectableMemoryError00
1.3.6.1.4.1.232.0.6016 cpqHe3CorrectableMemoryLogDisabled00
1.3.6.1.4.1.232.0.6017 cpqHe3ThermalTempFailed00
1.3.6.1.4.1.232.0.6018 cpqHe3ThermalTempDegraded00
1.3.6.1.4.1.232.0.6019 cpqHe3ThermalTempOk00
1.3.6.1.4.1.232.0.6020 cpqHe3ThermalSystemFanFailed00
1.3.6.1.4.1.232.0.6021 cpqHe3ThermalSystemFanDegraded00
1.3.6.1.4.1.232.0.6022 cpqHe3ThermalSystemFanOk00
1.3.6.1.4.1.232.0.6023 cpqHe3ThermalCpuFanFailed00
1.3.6.1.4.1.232.0.6024 cpqHe3ThermalCpuFanOk00
1.3.6.1.4.1.232.0.6025 cpqHe3AsrConfirmation00
1.3.6.1.4.1.232.0.6026 cpqHe3ThermalConfirmation00
1.3.6.1.4.1.232.0.6027 cpqHe3PostError00
1.3.6.1.4.1.232.0.6028 cpqHe3FltTolPwrSupplyDegraded00
1.3.6.1.4.1.232.0.6029 cpqHe3CorrMemReplaceMemModule00
1.3.6.1.4.1.232.0.6030 cpqHe3FltTolPowerSupplyDegraded00