Reference record for OID 1.3.6.1.4.1.232.0.13603423

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13603423
Node names
  • sCellEventTrap_d_5f
  • sCellEventTrap-0d-5f
Numeric OID
1.3.6.1.4.1.232.0.13603423
URN notation
urn:oid:1.3.6.1.4.1.232.0.13603423
ASN.1 notation

{1 3 6 1 4 1 232 0 13603423}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-5f(13603423)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-5f(13603423)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13603423
  • /ISO/Identified-Organization/6/1/4/1/232/0/13603423
  • /ISO/3/6/1/4/1/232/0/13603423
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-0d-5f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_d_5f
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-0d-5f
  • Additional combinations skipped.

Descriptions

sCellEventTrap-0d-5f — MIBdepot

Severity: Critical -- failure or failure imminent. The temperature of Enclosure Link Module temperature sensor is at a critical level. The operational power supply(s) will automatically shut down the drive bays after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values.

sCellEventTrap_d_5f — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. <P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

sCellEventTrap-0d-5f — HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C.

sCellEventTrap-0d-5f — Circitor, HPE networking MIB copies (LibreNMS/Observium Community)

Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values.

Source records

sCellEventTrap-0d-5f

Status in source: unspecified.

Names: sCellEventTrap-0d-5f

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5f",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The temperature of Enclosure Link Module temperature sensor is at a critical level. The operational power supply(s) will automatically shut down the drive bays after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values.\"",
    "::=",
    "13603423"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The temperature of Enclosure Link Module temperature sensor is at a critical level. The operational power supply(s) will automatically shut down the drive bays after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV300V9-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of Enclosure Link Module temperature sensor is at a critical level. The operational power supply(s) will automatically shut down the drive bays after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download eva4400_abm.mib.txt
    Source location: CPQHSV300V9-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Archived: 2026-10-19T00:22:08.878729+00:00.

sCellEventTrap_d_5f

Status in source: unspecified.

Names: sCellEventTrap_d_5f

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_d_5f",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. <P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13603423"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. <P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. <P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download cpqhsv110v3.mib.txt
    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_5f.
    Source version and references

    Archived: 2026-10-19T00:22:08.860954+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV110V3-MIB

    Published definition
    sCellEventTrap_d_5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. <P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV110V3-MIB

    Related source files and packages:


    Source location: CPQHSV110V3-MIB::sCellEventTrap_d_5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.221277+00:00.

sCellEventTrap-0d-5f

Status in source: unspecified.

Names: sCellEventTrap-0d-5f

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5f",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C.\"",
    "::=",
    "13603423"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV340V11-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV340V11-MIB

    Related source files and packages:


    Source location: CPQHSV340V11-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.567295+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV300V11-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5f8706"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV300V11-MIB

    Related source files and packages:


    Source location: CPQHSV300V11-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.614294+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV360V11-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5f8706"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV360V11-MIB

    Related source files and packages:


    Source location: CPQHSV360V11-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.078281+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV450V11-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5f8706"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV450V11-MIB

    Related source files and packages:


    Source location: CPQHSV450V11-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.258276+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV400V11-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The temperature of a Enclosure Link Module temperature sensor or Midplane temperature sensor of the disk enclosure is at critical level. The Enterprise Virtual Array system will automatically shut down if the average temperature of all the temperature sensors (IOA, IOB, and 2 Midplane temperature sensors) of the disk enclosure is at or above 50C."
               --#TYPE      "StorageCell Event 0d5f8706"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV400V11-MIB

    Related source files and packages:


    Source location: CPQHSV400V11-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.360273+00:00.

sCellEventTrap-0d-5f

Status in source: unspecified.

Names: sCellEventTrap-0d-5f

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-5f",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values.\"",
    "::=",
    "13603423"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
    ],
    null
  ]
}
  • Preserved circitor archive

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB.mib
    Source location: CPQHSV-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Archived: 2026-10-19T00:22:16.773182+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV200V6-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
               --#TYPE      "StorageCell Event 0d5f8711"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV200V6-MIB

    Related source files and packages:


    Source location: CPQHSV200V6-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:40.557296+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQHSV-MIB

    Published definition
    sCellEventTrap-0d-5f TRAP-TYPE  -- CAC Code: 87
            ENTERPRISE compaq
            VARIABLES  { scellNameDateTime,
                         scellSWComponent,
                         scellECode,
                         scellCAC,
                         scellEIP}
            DESCRIPTION
                 "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. Refer to the HSV element manager GUI for the temperature threshold values."
               --#TYPE      "StorageCell Event"
               --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
               --#ARGUMENTS {0,1,2,3,4,}
               --#SEVERITY  CRITICAL
               --#TIMEINDEX 136
               --#STATE     WARNING
            ::= 13603423
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download CPQHSV-MIB

    Related source files and packages:


    Source location: CPQHSV-MIB::sCellEventTrap-0d-5f.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.025282+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.13602430 sCellEventTrap-09-7e00
1.3.6.1.4.1.232.0.13602431 sCellEventTrap-09-7f00
1.3.6.1.4.1.232.0.13602432 sCellEventTrap-09-8000
1.3.6.1.4.1.232.0.13602433 sCellEventTrap-09-8100
1.3.6.1.4.1.232.0.13602434 sCellEventTrap-09-8200
1.3.6.1.4.1.232.0.13602435 sCellEventTrap-09-8300
1.3.6.1.4.1.232.0.13602504 sCellEventTrap_9_c8, sCellEventTrap-09-c800
1.3.6.1.4.1.232.0.13602505 sCellEventTrap_9_c9, sCellEventTrap-09-c900
1.3.6.1.4.1.232.0.13602506 sCellEventTrap_9_ca, sCellEventTrap-09-ca00
1.3.6.1.4.1.232.0.13602507 sCellEventTrap_9_cb, sCellEventTrap-09-cb00
1.3.6.1.4.1.232.0.13602508 sCellEventTrap_9_cc, sCellEventTrap-09-cc00
1.3.6.1.4.1.232.0.13602509 sCellEventTrap_9_cd, sCellEventTrap-09-cd00
1.3.6.1.4.1.232.0.13602510 sCellEventTrap_9_ce, sCellEventTrap-09-ce00
1.3.6.1.4.1.232.0.13602511 sCellEventTrap_9_cf, sCellEventTrap-09-cf00
1.3.6.1.4.1.232.0.13602512 sCellEventTrap_9_d0, sCellEventTrap-09-d000
1.3.6.1.4.1.232.0.13602513 sCellEventTrap_9_d1, sCellEventTrap-09-d100
1.3.6.1.4.1.232.0.13602514 sCellEventTrap_9_d2, sCellEventTrap-09-d200
1.3.6.1.4.1.232.0.13602515 sCellEventTrap_9_d3, sCellEventTrap-09-d300
1.3.6.1.4.1.232.0.13602516 sCellEventTrap_9_d4, sCellEventTrap-09-d400
1.3.6.1.4.1.232.0.13602517 sCellEventTrap_9_d5, sCellEventTrap-09-d500
1.3.6.1.4.1.232.0.13602518 sCellEventTrap_9_d6, sCellEventTrap-09-d600
1.3.6.1.4.1.232.0.13602519 sCellEventTrap_9_d7, sCellEventTrap-09-d700
1.3.6.1.4.1.232.0.13602520 sCellEventTrap-09-d800
1.3.6.1.4.1.232.0.13602521 sCellEventTrap-09-d900
1.3.6.1.4.1.232.0.13602522 sCellEventTrap-09-da00
1.3.6.1.4.1.232.0.13602523 sCellEventTrap-09-db00
1.3.6.1.4.1.232.0.13602524 sCellEventTrap-09-dc00
1.3.6.1.4.1.232.0.13602525 sCellEventTrap-09-dd00
1.3.6.1.4.1.232.0.13602526 sCellEventTrap-09-de00
1.3.6.1.4.1.232.0.13602531 sCellEventTrap-09-e300
1.3.6.1.4.1.232.0.13602532 sCellEventTrap-09-e400
1.3.6.1.4.1.232.0.13602533 sCellEventTrap-09-e500
1.3.6.1.4.1.232.0.13602535 sCellEventTrap-09-e700
1.3.6.1.4.1.232.0.13602536 sCellEventTrap-09-e800
1.3.6.1.4.1.232.0.13602537 sCellEventTrap-09-e900
1.3.6.1.4.1.232.0.13602538 sCellEventTrap-09-ea00
1.3.6.1.4.1.232.0.13602539 sCellEventTrap-09-eb00
1.3.6.1.4.1.232.0.13602540 sCellEventTrap-09-ec00
1.3.6.1.4.1.232.0.13602541 sCellEventTrap-09-ed00
1.3.6.1.4.1.232.0.13602542 sCellEventTrap-09-ee00
1.3.6.1.4.1.232.0.13602816 sCellEventTrap_b_0, sCellEventTrap-0b-0000
1.3.6.1.4.1.232.0.13602817 sCellEventTrap-0b-0100
1.3.6.1.4.1.232.0.13602818 sCellEventTrap-0b-0200
1.3.6.1.4.1.232.0.13602819 sCellEventTrap-0b-0300
1.3.6.1.4.1.232.0.13602820 sCellEventTrap-0b-0400
1.3.6.1.4.1.232.0.13602821 sCellEventTrap-0b-0500
1.3.6.1.4.1.232.0.13602822 sCellEventTrap-0b-0600
1.3.6.1.4.1.232.0.13602823 sCellEventTrap-0b-0700
1.3.6.1.4.1.232.0.13602825 sCellEventTrap-0b-0900
1.3.6.1.4.1.232.0.13602827 sCellEventTrap-0b-0b00