sCellEventTrap_d_b5

1.3.6.1.4.1.232.0.13603509

Description

Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.232.0 (0)
Node code
13603509
Node names
  • sCellEventTrap_d_b5
  • sCellEventTrap-0d-b5
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.232.0.13603509
URN notation
urn:oid:1.3.6.1.4.1.232.0.13603509
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 232 0 13603509}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 sCellEventTrap-0d-b5(13603509)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 sCellEventTrap-0d-b5(13603509)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/13603509
  • /ISO/Identified-Organization/6/1/4/1/232/0/13603509
  • /ISO/3/6/1/4/1/232/0/13603509
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/sCellEventTrap-0d-b5
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap_d_b5
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/sCellEventTrap-0d-b5
  • Additional combinations skipped.

Available source records contain 3 distinct definitions; some records may not include a definition.

Show 3 published definitions

sCellEventTrap-0d-b5 · unspecified

sCellEventTrap-0d-b5 TRAP-TYPE  -- CAC Code: 81
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported."
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  CRITICAL
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13603509

sCellEventTrap-0d-b5 · unspecified

sCellEventTrap-0d-b5 TRAP-TYPE  -- CAC Code: 81
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported."
           --#TYPE      "StorageCell Event 0db58111"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  CRITICAL
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13603509

sCellEventTrap_d_b5 · unspecified

sCellEventTrap_d_b5 TRAP-TYPE  -- CAC Code: 81
        ENTERPRISE compaq
        VARIABLES  { scellNameDateTime,
                     scellSWComponent,
                     scellECode,
                     scellCAC,
                     scellEIP}
        DESCRIPTION
             "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element current is above the high current CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
           --#TYPE      "StorageCell Event"
           --#SUMMARY   "SCellName-TimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d."
           --#ARGUMENTS {0,1,2,3,4,}
           --#SEVERITY  CRITICAL
           --#TIMEINDEX 136
           --#STATE     WARNING
        ::= 13603509

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported.

Sources for this description

CircitorHPE networking MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element current is above the high current CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.

Sources for this description

HPE networking MIB copies (LibreNMS/Observium Community)MIBdepot

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Circitor, HPE networking MIB copies (LibreNMS/Observium Community)1 record · 3 sources

Description 1

sCellEventTrap-0d-b5 · unspecifiedCircitor, HPE networking MIB copies (LibreNMS/Observium Community)3 sources

Status in source: unspecified.

Names: sCellEventTrap-0d-b5

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap-0d-b5",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported.\"",
    "::=",
    "13603509"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported."
    ],
    null
  ]
}
Records for description 2HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot1 record · 2 sources

Description 2

sCellEventTrap_d_b5 · unspecifiedHPE networking MIB copies (LibreNMS/Observium Community), MIBdepot2 sources

Status in source: unspecified.

Names: sCellEventTrap_d_b5

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sCellEventTrap_d_b5",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "scellNameDateTime",
    ",",
    "scellSWComponent",
    ",",
    "scellECode",
    ",",
    "scellCAC",
    ",",
    "scellEIP",
    "}",
    "DESCRIPTION",
    "\"Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element current is above the high current CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.\"",
    "::=",
    "13603509"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "scellNameDateTime",
        "scellSWComponent",
        "scellECode",
        "scellCAC",
        "scellEIP"
      ]
    ],
    [
      "DESCRIPTION",
      "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element current is above the high current CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release."
    ],
    null
  ]
}

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.5006 cpqScsi3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5007 cpqTape3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5008 cpqTape3PhyDrvCleaningRequired00
1.3.6.1.4.1.232.0.5009 cpqTape3PhyDrvCleanTapeReplace00
1.3.6.1.4.1.232.0.5010 cpqTape3LibraryFailed00
1.3.6.1.4.1.232.0.5011 cpqTape3LibraryOkay00
1.3.6.1.4.1.232.0.5012 cpqTape3LibraryDegraded00
1.3.6.1.4.1.232.0.5013 cpqTape3LibraryDoorOpen00
1.3.6.1.4.1.232.0.5014 cpqTape3LibraryDoorClosed00
1.3.6.1.4.1.232.0.5015 cpqScsiCdLibraryStatusChange00
1.3.6.1.4.1.232.0.5016 cpqTape4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5017 cpqScsi4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5018 cpqTapeLibraryStatusChange00
1.3.6.1.4.1.232.0.5019 cpqTape5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5020 cpqScsi5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5021 cpqScsi3LogDrvStatusChange00
1.3.6.1.4.1.232.0.5022 cpqSasPhyDrvStatusChange00
1.3.6.1.4.1.232.0.5023 cpqSasLogDrvStatusChange00
1.3.6.1.4.1.232.0.5025 cpqSas2TapeDrvStatusChange00
1.3.6.1.4.1.232.0.5026 cpqSasPhyDrvSSDWearStatusChange00
1.3.6.1.4.1.232.0.6001 cpqHe2CorrectableMemoryError00
1.3.6.1.4.1.232.0.6002 cpqHe2CorrectableMemoryLogDisabled00
1.3.6.1.4.1.232.0.6003 cpqHeThermalTempFailed00
1.3.6.1.4.1.232.0.6004 cpqHeThermalTempDegraded00
1.3.6.1.4.1.232.0.6005 cpqHeThermalTempOk00
1.3.6.1.4.1.232.0.6006 cpqHeThermalSystemFanFailed00
1.3.6.1.4.1.232.0.6007 cpqHeThermalSystemFanDegraded00
1.3.6.1.4.1.232.0.6008 cpqHeThermalSystemFanOk00
1.3.6.1.4.1.232.0.6009 cpqHeThermalCpuFanFailed00
1.3.6.1.4.1.232.0.6010 cpqHeThermalCpuFanOk00
1.3.6.1.4.1.232.0.6011 cpqHeAsrConfirmation00
1.3.6.1.4.1.232.0.6012 cpqHeThermalConfirmation00
1.3.6.1.4.1.232.0.6013 cpqHePostError00
1.3.6.1.4.1.232.0.6014 cpqHeFltTolPwrSupplyDegraded00
1.3.6.1.4.1.232.0.6015 cpqHe3CorrectableMemoryError00
1.3.6.1.4.1.232.0.6016 cpqHe3CorrectableMemoryLogDisabled00
1.3.6.1.4.1.232.0.6017 cpqHe3ThermalTempFailed00
1.3.6.1.4.1.232.0.6018 cpqHe3ThermalTempDegraded00
1.3.6.1.4.1.232.0.6019 cpqHe3ThermalTempOk00
1.3.6.1.4.1.232.0.6020 cpqHe3ThermalSystemFanFailed00
1.3.6.1.4.1.232.0.6021 cpqHe3ThermalSystemFanDegraded00
1.3.6.1.4.1.232.0.6022 cpqHe3ThermalSystemFanOk00
1.3.6.1.4.1.232.0.6023 cpqHe3ThermalCpuFanFailed00
1.3.6.1.4.1.232.0.6024 cpqHe3ThermalCpuFanOk00
1.3.6.1.4.1.232.0.6025 cpqHe3AsrConfirmation00
1.3.6.1.4.1.232.0.6026 cpqHe3ThermalConfirmation00
1.3.6.1.4.1.232.0.6027 cpqHe3PostError00
1.3.6.1.4.1.232.0.6028 cpqHe3FltTolPwrSupplyDegraded00
1.3.6.1.4.1.232.0.6029 cpqHe3CorrMemReplaceMemModule00
1.3.6.1.4.1.232.0.6030 cpqHe3FltTolPowerSupplyDegraded00