cpqIdeAtaDiskStatusChange
Numeric OID
1.3.6.1.4.1.232.0.14004
URN notation
urn:oid:1.3.6.1.4.1.232.0.14004
ASN.1 notation

{1 3 6 1 4 1 232 0 14004}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/14004
  • /ISO/Identified-Organization/6/1/4/1/232/0/14004
  • /ISO/3/6/1/4/1/232/0/14004
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqIdeAtaDiskStatusChange
  • Additional combinations skipped.

Descriptions

cpqIdeAtaDiskStatusChange — HPE networking MIB copies (LibreNMS/Observium Community)

ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, `failed(4)` or `ssdWearOut(5)` replace the drive.

cpqIdeAtaDiskStatusChange — Circitor, MIBdepot

ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive.

Source records

cpqIdeAtaDiskStatusChange

Status in source: unspecified.

Names: cpqIdeAtaDiskStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqIdeAtaDiskStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqIdeAtaDiskControllerIndex",
    ",",
    "cpqIdeAtaDiskIndex",
    ",",
    "cpqIdeAtaDiskModel",
    ",",
    "cpqIdeAtaDiskFwRev",
    ",",
    "cpqIdeAtaDiskSerialNumber",
    ",",
    "cpqIdeAtaDiskStatus",
    ",",
    "cpqIdeAtaDiskChannel",
    ",",
    "cpqIdeAtaDiskNumber",
    "}",
    "DESCRIPTION",
    "\"ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, `failed(4)` or `ssdWearOut(5)` replace the drive.\"",
    "::=",
    "14004"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqIdeAtaDiskControllerIndex",
        "cpqIdeAtaDiskIndex",
        "cpqIdeAtaDiskModel",
        "cpqIdeAtaDiskFwRev",
        "cpqIdeAtaDiskSerialNumber",
        "cpqIdeAtaDiskStatus",
        "cpqIdeAtaDiskChannel",
        "cpqIdeAtaDiskNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, `failed(4)` or `ssdWearOut(5)` replace the drive."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, 
                 `failed(4)` or `ssdWearOut(5)` replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change (14004)"
            --#SUMMARY "ATA disk drive status is now %d for drive %d."
            --#ARGUMENTS {7, 9}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY STORAGE
            --#ACTION "If the disk drive status is 'smartError(3)', 'failed(4)' or 'ssdWearOut(5)', replace the drive."
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE-MIB

    Related source files and packages:


    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.176278+00:00.

cpqIdeAtaDiskStatusChange

Status in source: unspecified.

Names: cpqIdeAtaDiskStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqIdeAtaDiskStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqIdeAtaDiskControllerIndex",
    ",",
    "cpqIdeAtaDiskIndex",
    ",",
    "cpqIdeAtaDiskModel",
    ",",
    "cpqIdeAtaDiskFwRev",
    ",",
    "cpqIdeAtaDiskSerialNumber",
    ",",
    "cpqIdeAtaDiskStatus",
    ",",
    "cpqIdeAtaDiskChannel",
    ",",
    "cpqIdeAtaDiskNumber",
    "}",
    "DESCRIPTION",
    "\"ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive.\"",
    "::=",
    "14004"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqIdeAtaDiskControllerIndex",
        "cpqIdeAtaDiskIndex",
        "cpqIdeAtaDiskModel",
        "cpqIdeAtaDiskFwRev",
        "cpqIdeAtaDiskSerialNumber",
        "cpqIdeAtaDiskStatus",
        "cpqIdeAtaDiskChannel",
        "cpqIdeAtaDiskNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If the physical drive status is smartError(3) or
                 failed(4), replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change (14004)"
            --#SUMMARY "Status is now %d for the ATA disk."
            --#ARGUMENTS {7}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE.MIB.txt
    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.784225+00:00.

  • Preserved mibdepot archive

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If the physical drive status is smartError(3) or
                 failed(4), replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change"
            --#SUMMARY "Status is now %d for the ATA disk."
            --#ARGUMENTS {7}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE1.MIB.txt
    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.784568+00:00.

  • Preserved circitor archive

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If the physical drive status is smartError(3) or
                 failed(4), replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change (14004)"
            --#SUMMARY "Status is now %d for the ATA disk."
            --#ARGUMENTS {7}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE-MIB.mib
    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:16.780674+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.1001 cpqSeCpuThresholdPassed00
1.3.6.1.4.1.232.0.1002 cpqSePCCardThermalDegraded00
1.3.6.1.4.1.232.0.1003 cpqSePCCardThermalFailure00
1.3.6.1.4.1.232.0.1004 cpqSePCCardThermalSafe00
1.3.6.1.4.1.232.0.1005 cpqSe2CpuThresholdPassed00
1.3.6.1.4.1.232.0.1006 cpqSeCpuStatusChange00
1.3.6.1.4.1.232.0.1007 cpqSeCpuPowerPodstatusChange00
1.3.6.1.4.1.232.0.1008 cpqSeUSBStorageDeviceAttached00
1.3.6.1.4.1.232.0.1009 cpqSeUSBStorageDeviceRemoved00
1.3.6.1.4.1.232.0.1010 cpqSeUSBStorageDeviceReadErrorOccurred00
1.3.6.1.4.1.232.0.1011 cpqSeUSBStorageDeviceWriteErrorOccurred00
1.3.6.1.4.1.232.0.1012 cpqSeUSBStorageDeviceRedundancyLost00
1.3.6.1.4.1.232.0.1013 cpqSeUSBStorageDeviceRedundancyRestored00
1.3.6.1.4.1.232.0.1014 cpqSeUSBStorageDeviceSyncFailed00
1.3.6.1.4.1.232.0.1015 cpqSePCIeDiskTemperatureFailed00
1.3.6.1.4.1.232.0.1016 cpqSePCIeDiskTemperatureOk00
1.3.6.1.4.1.232.0.1017 cpqSePCIeDiskConditionChange00
1.3.6.1.4.1.232.0.1018 cpqSePCIeDiskWearStatusChange00
1.3.6.1.4.1.232.0.1019 cpqSePciDeviceAddedOrPoweredOn00
1.3.6.1.4.1.232.0.1020 cpqSePciDeviceRemovedOrPoweredOff00
1.3.6.1.4.1.232.0.1021 cpqSeNVMeSecureEraseFailed00
1.3.6.1.4.1.232.0.1022 cpqSePcieTrainingFailed00
1.3.6.1.4.1.232.0.1023 cpqSePciResetFail00
1.3.6.1.4.1.232.0.1024 cpqSeSecureBootAuthFail00
1.3.6.1.4.1.232.0.1025 cpqSeSecureBootCertAuthFail00
1.3.6.1.4.1.232.0.1026 cpqSeCpuUncorrectableError00
1.3.6.1.4.1.232.0.1027 cpqSeInternalCpuError00
1.3.6.1.4.1.232.0.2001 cpqSiHoodRemoved00
1.3.6.1.4.1.232.0.2002 cpqSiMonitorConditionOK00
1.3.6.1.4.1.232.0.2003 cpqSiMonitorConditionDegraded00
1.3.6.1.4.1.232.0.2004 cpqSiMonitorConditionFailed00
1.3.6.1.4.1.232.0.2005 cpqSiCorrMemErrStatusDegraded00
1.3.6.1.4.1.232.0.2006 cpqSiCorrMemErrStatusOk00
1.3.6.1.4.1.232.0.2007 cpqSiMemConfigChange00
1.3.6.1.4.1.232.0.2008 cpqSiHotPlugSlotBoardRemoved00
1.3.6.1.4.1.232.0.2009 cpqSiHotPlugSlotBoardInserted00
1.3.6.1.4.1.232.0.2010 cpqSiHotPlugSlotPowerUpFailed00
1.3.6.1.4.1.232.0.2011 cpqSiSysBatteryFailure00
1.3.6.1.4.1.232.0.2012 cpqSiSysBatteryChargingDegraded00
1.3.6.1.4.1.232.0.2013 cpqSiSysBatteryCalibrationError00
1.3.6.1.4.1.232.0.2014 cpqSiIntrusionInstalled00
1.3.6.1.4.1.232.0.2015 cpqSiIntrusionRemoved00
1.3.6.1.4.1.232.0.2016 cpqSiHoodReplaced00
1.3.6.1.4.1.232.0.2017 cpqSiHoodRemovedOnPowerOff00
1.3.6.1.4.1.232.0.2018 cpqSiSysTelemetryThresholdAlert00
1.3.6.1.4.1.232.0.3001 cpqDa2LogDrvStatusChange00
1.3.6.1.4.1.232.0.3002 cpqDa2SpareStatusChange00
1.3.6.1.4.1.232.0.3003 cpqDa2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3004 cpqDa2PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3005 cpqDa2AccelStatusChange00