Reference record for OID 1.3.6.1.4.1.232.0.14004

Parent
1.3.6.1.4.1.232.0 (0)
Node code
14004
Node name
cpqIdeAtaDiskStatusChange
Numeric OID
1.3.6.1.4.1.232.0.14004
URN notation
urn:oid:1.3.6.1.4.1.232.0.14004
ASN.1 notation

{1 3 6 1 4 1 232 0 14004}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqIdeAtaDiskStatusChange(14004)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/14004
  • /ISO/Identified-Organization/6/1/4/1/232/0/14004
  • /ISO/3/6/1/4/1/232/0/14004
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqIdeAtaDiskStatusChange
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqIdeAtaDiskStatusChange
  • Additional combinations skipped.

Descriptions

cpqIdeAtaDiskStatusChange — HPE networking MIB copies (LibreNMS/Observium Community)

ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, `failed(4)` or `ssdWearOut(5)` replace the drive.

cpqIdeAtaDiskStatusChange — Circitor, MIBdepot

ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive.

Source records

cpqIdeAtaDiskStatusChange

Status in source: unspecified.

Names: cpqIdeAtaDiskStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqIdeAtaDiskStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqIdeAtaDiskControllerIndex",
    ",",
    "cpqIdeAtaDiskIndex",
    ",",
    "cpqIdeAtaDiskModel",
    ",",
    "cpqIdeAtaDiskFwRev",
    ",",
    "cpqIdeAtaDiskSerialNumber",
    ",",
    "cpqIdeAtaDiskStatus",
    ",",
    "cpqIdeAtaDiskChannel",
    ",",
    "cpqIdeAtaDiskNumber",
    "}",
    "DESCRIPTION",
    "\"ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, `failed(4)` or `ssdWearOut(5)` replace the drive.\"",
    "::=",
    "14004"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqIdeAtaDiskControllerIndex",
        "cpqIdeAtaDiskIndex",
        "cpqIdeAtaDiskModel",
        "cpqIdeAtaDiskFwRev",
        "cpqIdeAtaDiskSerialNumber",
        "cpqIdeAtaDiskStatus",
        "cpqIdeAtaDiskChannel",
        "cpqIdeAtaDiskNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, `failed(4)` or `ssdWearOut(5)` replace the drive."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If cpqIdeAtaDiskStatus is `smartError(3)`, 
                 `failed(4)` or `ssdWearOut(5)` replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change (14004)"
            --#SUMMARY "ATA disk drive status is now %d for drive %d."
            --#ARGUMENTS {7, 9}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY STORAGE
            --#ACTION "If the disk drive status is 'smartError(3)', 'failed(4)' or 'ssdWearOut(5)', replace the drive."
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE-MIB

    Related source files and packages:


    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.176278+00:00.

cpqIdeAtaDiskStatusChange

Status in source: unspecified.

Names: cpqIdeAtaDiskStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqIdeAtaDiskStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqIdeAtaDiskControllerIndex",
    ",",
    "cpqIdeAtaDiskIndex",
    ",",
    "cpqIdeAtaDiskModel",
    ",",
    "cpqIdeAtaDiskFwRev",
    ",",
    "cpqIdeAtaDiskSerialNumber",
    ",",
    "cpqIdeAtaDiskStatus",
    ",",
    "cpqIdeAtaDiskChannel",
    ",",
    "cpqIdeAtaDiskNumber",
    "}",
    "DESCRIPTION",
    "\"ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive.\"",
    "::=",
    "14004"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqIdeAtaDiskControllerIndex",
        "cpqIdeAtaDiskIndex",
        "cpqIdeAtaDiskModel",
        "cpqIdeAtaDiskFwRev",
        "cpqIdeAtaDiskSerialNumber",
        "cpqIdeAtaDiskStatus",
        "cpqIdeAtaDiskChannel",
        "cpqIdeAtaDiskNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "ATA Disk Status Change. This trap signifies that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If the physical drive status is smartError(3) or
                 failed(4), replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change (14004)"
            --#SUMMARY "Status is now %d for the ATA disk."
            --#ARGUMENTS {7}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE.MIB.txt
    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.784225+00:00.

  • Preserved mibdepot archive

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If the physical drive status is smartError(3) or
                 failed(4), replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change"
            --#SUMMARY "Status is now %d for the ATA disk."
            --#ARGUMENTS {7}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE1.MIB.txt
    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.784568+00:00.

  • Preserved circitor archive

    Module: CPQIDE-MIB

    Published definition
    cpqIdeAtaDiskStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
                         cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
                         cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
                         cpqIdeAtaDiskStatus, cpqIdeAtaDiskChannel,
                         cpqIdeAtaDiskNumber }
            DESCRIPTION
                "ATA Disk Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of an ATA disk drive.  The variable cpqIdeAtaDiskStatus
                 indicates the current disk drive status.
    
                 User Action: If the physical drive status is smartError(3) or
                 failed(4), replace the drive."
    
            --#TYPE "ATA Disk Drive Status Change (14004)"
            --#SUMMARY "Status is now %d for the ATA disk."
            --#ARGUMENTS {7}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            ::= 14004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDE-MIB.mib
    Source location: CPQIDE-MIB::cpqIdeAtaDiskStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:16.780674+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.5006 cpqScsi3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5007 cpqTape3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5008 cpqTape3PhyDrvCleaningRequired00
1.3.6.1.4.1.232.0.5009 cpqTape3PhyDrvCleanTapeReplace00
1.3.6.1.4.1.232.0.5010 cpqTape3LibraryFailed00
1.3.6.1.4.1.232.0.5011 cpqTape3LibraryOkay00
1.3.6.1.4.1.232.0.5012 cpqTape3LibraryDegraded00
1.3.6.1.4.1.232.0.5013 cpqTape3LibraryDoorOpen00
1.3.6.1.4.1.232.0.5014 cpqTape3LibraryDoorClosed00
1.3.6.1.4.1.232.0.5015 cpqScsiCdLibraryStatusChange00
1.3.6.1.4.1.232.0.5016 cpqTape4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5017 cpqScsi4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5018 cpqTapeLibraryStatusChange00
1.3.6.1.4.1.232.0.5019 cpqTape5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5020 cpqScsi5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5021 cpqScsi3LogDrvStatusChange00
1.3.6.1.4.1.232.0.5022 cpqSasPhyDrvStatusChange00
1.3.6.1.4.1.232.0.5023 cpqSasLogDrvStatusChange00
1.3.6.1.4.1.232.0.5025 cpqSas2TapeDrvStatusChange00
1.3.6.1.4.1.232.0.5026 cpqSasPhyDrvSSDWearStatusChange00
1.3.6.1.4.1.232.0.6001 cpqHe2CorrectableMemoryError00
1.3.6.1.4.1.232.0.6002 cpqHe2CorrectableMemoryLogDisabled00
1.3.6.1.4.1.232.0.6003 cpqHeThermalTempFailed00
1.3.6.1.4.1.232.0.6004 cpqHeThermalTempDegraded00
1.3.6.1.4.1.232.0.6005 cpqHeThermalTempOk00
1.3.6.1.4.1.232.0.6006 cpqHeThermalSystemFanFailed00
1.3.6.1.4.1.232.0.6007 cpqHeThermalSystemFanDegraded00
1.3.6.1.4.1.232.0.6008 cpqHeThermalSystemFanOk00
1.3.6.1.4.1.232.0.6009 cpqHeThermalCpuFanFailed00
1.3.6.1.4.1.232.0.6010 cpqHeThermalCpuFanOk00
1.3.6.1.4.1.232.0.6011 cpqHeAsrConfirmation00
1.3.6.1.4.1.232.0.6012 cpqHeThermalConfirmation00
1.3.6.1.4.1.232.0.6013 cpqHePostError00
1.3.6.1.4.1.232.0.6014 cpqHeFltTolPwrSupplyDegraded00
1.3.6.1.4.1.232.0.6015 cpqHe3CorrectableMemoryError00
1.3.6.1.4.1.232.0.6016 cpqHe3CorrectableMemoryLogDisabled00
1.3.6.1.4.1.232.0.6017 cpqHe3ThermalTempFailed00
1.3.6.1.4.1.232.0.6018 cpqHe3ThermalTempDegraded00
1.3.6.1.4.1.232.0.6019 cpqHe3ThermalTempOk00
1.3.6.1.4.1.232.0.6020 cpqHe3ThermalSystemFanFailed00
1.3.6.1.4.1.232.0.6021 cpqHe3ThermalSystemFanDegraded00
1.3.6.1.4.1.232.0.6022 cpqHe3ThermalSystemFanOk00
1.3.6.1.4.1.232.0.6023 cpqHe3ThermalCpuFanFailed00
1.3.6.1.4.1.232.0.6024 cpqHe3ThermalCpuFanOk00
1.3.6.1.4.1.232.0.6025 cpqHe3AsrConfirmation00
1.3.6.1.4.1.232.0.6026 cpqHe3ThermalConfirmation00
1.3.6.1.4.1.232.0.6027 cpqHe3PostError00
1.3.6.1.4.1.232.0.6028 cpqHe3FltTolPwrSupplyDegraded00
1.3.6.1.4.1.232.0.6029 cpqHe3CorrMemReplaceMemModule00
1.3.6.1.4.1.232.0.6030 cpqHe3FltTolPowerSupplyDegraded00