Reference record for OID 1.3.6.1.4.1.232.0.161015

Parent
1.3.6.1.4.1.232.0 (0)
Node code
161015
Node name
switchSNTPServiceUnavailable
Numeric OID
1.3.6.1.4.1.232.0.161015
URN notation
urn:oid:1.3.6.1.4.1.232.0.161015
ASN.1 notation

{1 3 6 1 4 1 232 0 161015}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 switchSNTPServiceUnavailable(161015)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 switchSNTPServiceUnavailable(161015)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/161015
  • /ISO/Identified-Organization/6/1/4/1/232/0/161015
  • /ISO/3/6/1/4/1/232/0/161015
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/switchSNTPServiceUnavailable
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/switchSNTPServiceUnavailable
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/switchSNTPServiceUnavailable
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/switchSNTPServiceUnavailable
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/switchSNTPServiceUnavailable
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/switchSNTPServiceUnavailable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/switchSNTPServiceUnavailable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/switchSNTPServiceUnavailable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/switchSNTPServiceUnavailable
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/switchSNTPServiceUnavailable
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/switchSNTPServiceUnavailable
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/switchSNTPServiceUnavailable
  • /iso/org/dod/internet/private/enterprise/compaq/0/switchSNTPServiceUnavailable
  • /iso/org/dod/internet/private/enterprise/hp/0/switchSNTPServiceUnavailable
  • /iso/org/dod/internet/private/enterprise/Compaq/0/switchSNTPServiceUnavailable
  • /iso/org/dod/internet/private/enterprises/compaq/0/switchSNTPServiceUnavailable
  • Additional combinations skipped.

Descriptions

switchSNTPServiceUnavailable — HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

A SNTP Server was configured, but no SNTP servers were found. This trap is sent once if SNTP is enabled, a SNTP server is configured, and a SNTP server could not be contacted for 10 minutes from the start time. The start time will be defined as when both SNTP was enabled and a SNTP server was configured or when a SNTP server was contacted successfully.

Source records

switchSNTPServiceUnavailable

Status in source: unspecified.

Names: switchSNTPServiceUnavailable

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "switchSNTPServiceUnavailable",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "cpqRackUid",
    ",",
    "cpqRackCommonEnclosureSerialNum",
    ",",
    "cpqRackNetConnectorSerialNum",
    ",",
    "cpqRackName",
    ",",
    "cpqRackCommonEnclosureName",
    ",",
    "cpqRackNetConnectorName",
    ",",
    "cpqRackNetConnectorLocation",
    ",",
    "agentSNTPServer1IPAddr",
    ",",
    "agentSNTPServer2IPAddr",
    "}",
    "DESCRIPTION",
    "\"A SNTP Server was configured, but no SNTP servers were found. This trap is sent once if SNTP is enabled, a SNTP server is configured, and a SNTP server could not be contacted for 10 minutes from the start time. The start time will be defined as when both SNTP was enabled and a SNTP server was configured or when a SNTP server was contacted successfully.\"",
    "::=",
    "161015"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "cpqRackUid",
        "cpqRackCommonEnclosureSerialNum",
        "cpqRackNetConnectorSerialNum",
        "cpqRackName",
        "cpqRackCommonEnclosureName",
        "cpqRackNetConnectorName",
        "cpqRackNetConnectorLocation",
        "agentSNTPServer1IPAddr",
        "agentSNTPServer2IPAddr"
      ]
    ],
    [
      "DESCRIPTION",
      "A SNTP Server was configured, but no SNTP servers were found. This trap is sent once if SNTP is enabled, a SNTP server is configured, and a SNTP server could not be contacted for 10 minutes from the start time. The start time will be defined as when both SNTP was enabled and a SNTP server was configured or when a SNTP server was contacted successfully."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQ-TRAPS-MIB

    Published definition
    switchSNTPServiceUnavailable 	TRAP-TYPE
    		ENTERPRISE compaq
    		VARIABLES {
    			cpqRackUid,
    			cpqRackCommonEnclosureSerialNum,
    			cpqRackNetConnectorSerialNum,
    			cpqRackName,
    			cpqRackCommonEnclosureName,
    			cpqRackNetConnectorName,
    			cpqRackNetConnectorLocation,
    			agentSNTPServer1IPAddr,
    			agentSNTPServer2IPAddr
    		}
    		
    		DESCRIPTION
    		"A SNTP Server was configured, but no SNTP servers were found.
    		
    			This trap is sent once if SNTP is enabled,	 a SNTP server 
    		 is configured, and a SNTP server could not be contacted for 
    		 10 minutes from the start time.  The start time will be defined 
    		 as when both SNTP was enabled and a SNTP server was configured 
    		 or when a SNTP server was contacted successfully."
    		 
    		  --#SEVERITY MINOR
    		  
    	::= 161015
    Module imports
    {'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq'], 'CPQRACK-MIB': ['cpqRackUid', 'cpqRackCommonEnclosureSerialNum', 'cpqRackNetConnectorSerialNum', 'cpqRackName', 'cpqRackCommonEnclosureName', 'cpqRackNetConnectorName', 'cpqRackNetConnectorLocation', 'cpqRackNetConnectorFWRev', 'cpqRackNetConnectorSparePartNumber'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['mib-2'], 'COMPAQ-AGENT-MIB': ['agentBscSwFileAddr', 'agentBscSwFile', 'agentBscSwFileLoadType', 'agentBscSwFileStatus', 'agentSNTPServer1IPAddr', 'agentSNTPServer2IPAddr', 'agentSwitchFanIndex', 'agentSwitchFanCondition', 'agentSwitchTempSensorIndex', 'agentSwitchTempSensorCurrent', 'agentSwitchTempSensorThreshold', 'agentSwitchTempSensorCondition', 'agentSwitchTempSensorTempType', 'agentSwitchPowerSupplyMaxPwrOutput', 'agentSwitchPowerSupplyCurPwrOutput', 'agentSwitchPowerSupplyIntakeTemp', 'agentSwitchPowerSupplyExhaustTemp', 'agentSwitchPowerSupplyStatus', 'agentSwitchPowerSupplyInputLineStatus', 'agentSwitchPowerSupplyCondition', 'agentSwitchCubeType', 'agentSwitchCubeSpareName', 'agentSwitchCubeSparePartNumber'], 'COMPAQ-ID-REC-MIB': ['compaq-common-mgmt']}
    · Download cimtraps.mib.txt
    Source location: CPQ-TRAPS-MIB::switchSNTPServiceUnavailable.
    Source version and references

    Archived: 2026-10-19T00:22:08.836758+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQ-TRAPS-MIB

    Published definition
    switchSNTPServiceUnavailable 	TRAP-TYPE
    		ENTERPRISE compaq
    		VARIABLES {
    			cpqRackUid,
    			cpqRackCommonEnclosureSerialNum,
    			cpqRackNetConnectorSerialNum,
    			cpqRackName,
    			cpqRackCommonEnclosureName,
    			cpqRackNetConnectorName,
    			cpqRackNetConnectorLocation,
    			agentSNTPServer1IPAddr,
    			agentSNTPServer2IPAddr
    		}
    		
    		DESCRIPTION
    		"A SNTP Server was configured, but no SNTP servers were found.
    		
    			This trap is sent once if SNTP is enabled,	 a SNTP server 
    		 is configured, and a SNTP server could not be contacted for 
    		 10 minutes from the start time.  The start time will be defined 
    		 as when both SNTP was enabled and a SNTP server was configured 
    		 or when a SNTP server was contacted successfully."
    		 
    		  --#SEVERITY MINOR
    		  
    	::= 161015
    Module imports
    {'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq'], 'CPQRACK-MIB': ['cpqRackUid', 'cpqRackCommonEnclosureSerialNum', 'cpqRackNetConnectorSerialNum', 'cpqRackName', 'cpqRackCommonEnclosureName', 'cpqRackNetConnectorName', 'cpqRackNetConnectorLocation', 'cpqRackNetConnectorFWRev', 'cpqRackNetConnectorSparePartNumber'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['mib-2'], 'COMPAQ-AGENT-MIB': ['agentBscSwFileAddr', 'agentBscSwFile', 'agentBscSwFileLoadType', 'agentBscSwFileStatus', 'agentSNTPServer1IPAddr', 'agentSNTPServer2IPAddr', 'agentSwitchFanIndex', 'agentSwitchFanCondition', 'agentSwitchTempSensorIndex', 'agentSwitchTempSensorCurrent', 'agentSwitchTempSensorThreshold', 'agentSwitchTempSensorCondition', 'agentSwitchTempSensorTempType', 'agentSwitchPowerSupplyMaxPwrOutput', 'agentSwitchPowerSupplyCurPwrOutput', 'agentSwitchPowerSupplyIntakeTemp', 'agentSwitchPowerSupplyExhaustTemp', 'agentSwitchPowerSupplyStatus', 'agentSwitchPowerSupplyInputLineStatus', 'agentSwitchPowerSupplyCondition', 'agentSwitchCubeType', 'agentSwitchCubeSpareName', 'agentSwitchCubeSparePartNumber'], 'COMPAQ-ID-REC-MIB': ['compaq-common-mgmt']}
    · Download CPQ-TRAPS-MIB

    Related source files and packages:


    Source location: CPQ-TRAPS-MIB::switchSNTPServiceUnavailable.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.338274+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.1001 cpqSeCpuThresholdPassed00
1.3.6.1.4.1.232.0.1002 cpqSePCCardThermalDegraded00
1.3.6.1.4.1.232.0.1003 cpqSePCCardThermalFailure00
1.3.6.1.4.1.232.0.1004 cpqSePCCardThermalSafe00
1.3.6.1.4.1.232.0.1005 cpqSe2CpuThresholdPassed00
1.3.6.1.4.1.232.0.1006 cpqSeCpuStatusChange00
1.3.6.1.4.1.232.0.1007 cpqSeCpuPowerPodstatusChange00
1.3.6.1.4.1.232.0.1008 cpqSeUSBStorageDeviceAttached00
1.3.6.1.4.1.232.0.1009 cpqSeUSBStorageDeviceRemoved00
1.3.6.1.4.1.232.0.1010 cpqSeUSBStorageDeviceReadErrorOccurred00
1.3.6.1.4.1.232.0.1011 cpqSeUSBStorageDeviceWriteErrorOccurred00
1.3.6.1.4.1.232.0.1012 cpqSeUSBStorageDeviceRedundancyLost00
1.3.6.1.4.1.232.0.1013 cpqSeUSBStorageDeviceRedundancyRestored00
1.3.6.1.4.1.232.0.1014 cpqSeUSBStorageDeviceSyncFailed00
1.3.6.1.4.1.232.0.1015 cpqSePCIeDiskTemperatureFailed00
1.3.6.1.4.1.232.0.1016 cpqSePCIeDiskTemperatureOk00
1.3.6.1.4.1.232.0.1017 cpqSePCIeDiskConditionChange00
1.3.6.1.4.1.232.0.1018 cpqSePCIeDiskWearStatusChange00
1.3.6.1.4.1.232.0.1019 cpqSePciDeviceAddedOrPoweredOn00
1.3.6.1.4.1.232.0.1020 cpqSePciDeviceRemovedOrPoweredOff00
1.3.6.1.4.1.232.0.1021 cpqSeNVMeSecureEraseFailed00
1.3.6.1.4.1.232.0.1022 cpqSePcieTrainingFailed00
1.3.6.1.4.1.232.0.1023 cpqSePciResetFail00
1.3.6.1.4.1.232.0.1024 cpqSeSecureBootAuthFail00
1.3.6.1.4.1.232.0.1025 cpqSeSecureBootCertAuthFail00
1.3.6.1.4.1.232.0.1026 cpqSeCpuUncorrectableError00
1.3.6.1.4.1.232.0.1027 cpqSeInternalCpuError00
1.3.6.1.4.1.232.0.2001 cpqSiHoodRemoved00
1.3.6.1.4.1.232.0.2002 cpqSiMonitorConditionOK00
1.3.6.1.4.1.232.0.2003 cpqSiMonitorConditionDegraded00
1.3.6.1.4.1.232.0.2004 cpqSiMonitorConditionFailed00
1.3.6.1.4.1.232.0.2005 cpqSiCorrMemErrStatusDegraded00
1.3.6.1.4.1.232.0.2006 cpqSiCorrMemErrStatusOk00
1.3.6.1.4.1.232.0.2007 cpqSiMemConfigChange00
1.3.6.1.4.1.232.0.2008 cpqSiHotPlugSlotBoardRemoved00
1.3.6.1.4.1.232.0.2009 cpqSiHotPlugSlotBoardInserted00
1.3.6.1.4.1.232.0.2010 cpqSiHotPlugSlotPowerUpFailed00
1.3.6.1.4.1.232.0.2011 cpqSiSysBatteryFailure00
1.3.6.1.4.1.232.0.2012 cpqSiSysBatteryChargingDegraded00
1.3.6.1.4.1.232.0.2013 cpqSiSysBatteryCalibrationError00
1.3.6.1.4.1.232.0.2014 cpqSiIntrusionInstalled00
1.3.6.1.4.1.232.0.2015 cpqSiIntrusionRemoved00
1.3.6.1.4.1.232.0.2016 cpqSiHoodReplaced00
1.3.6.1.4.1.232.0.2017 cpqSiHoodRemovedOnPowerOff00
1.3.6.1.4.1.232.0.2018 cpqSiSysTelemetryThresholdAlert00
1.3.6.1.4.1.232.0.3001 cpqDa2LogDrvStatusChange00
1.3.6.1.4.1.232.0.3002 cpqDa2SpareStatusChange00
1.3.6.1.4.1.232.0.3003 cpqDa2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3004 cpqDa2PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3005 cpqDa2AccelStatusChange00