Reference record for OID 1.3.6.1.4.1.232.0.18004

Parent
1.3.6.1.4.1.232.0 (0)
Node code
18004
Node name
cpqNicRedundancyReduced
Numeric OID
1.3.6.1.4.1.232.0.18004
URN notation
urn:oid:1.3.6.1.4.1.232.0.18004
ASN.1 notation

{1 3 6 1 4 1 232 0 18004}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNicRedundancyReduced(18004)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNicRedundancyReduced(18004)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/18004
  • /ISO/Identified-Organization/6/1/4/1/232/0/18004
  • /ISO/3/6/1/4/1/232/0/18004
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqNicRedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqNicRedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqNicRedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqNicRedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqNicRedundancyReduced
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqNicRedundancyReduced
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqNicRedundancyReduced
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqNicRedundancyReduced
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqNicRedundancyReduced
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqNicRedundancyReduced
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqNicRedundancyReduced
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqNicRedundancyReduced
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqNicRedundancyReduced
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqNicRedundancyReduced
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqNicRedundancyReduced
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqNicRedundancyReduced
  • Additional combinations skipped.

Descriptions

cpqNicRedundancyReduced — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.

Source records

cpqNicRedundancyReduced

Status in source: unspecified.

Names: cpqNicRedundancyReduced

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNicRedundancyReduced",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    ",",
    "cpqNicIfLogMapAdapterOKCount",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement.\"",
    "::=",
    "18004"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort",
        "cpqNicIfLogMapAdapterOKCount"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNicRedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqNicIfLogMapAdapterOKCount}
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "Status Trap"
                 --#SUMMARY "Redundancy decreased by adapter in slot %s, port %s."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
            ::= 18004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download Cpqnic.mib.txt
    Source location: CPQNIC-MIB::cpqNicRedundancyReduced.
    Source version and references

    Archived: 2026-10-19T00:22:07.818687+00:00.

  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNicRedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqNicIfLogMapAdapterOKCount}
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Status Trap (18004)"
                 --#SUMMARY "Redundancy decreased by adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
            ::= 18004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC.MIB.txt
    Source location: CPQNIC-MIB::cpqNicRedundancyReduced.
    Source version and references

    Archived: 2026-10-19T00:22:08.785287+00:00.

  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNicRedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqNicIfLogMapAdapterOKCount}
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Status Trap"
                 --#SUMMARY "Redundancy decreased by adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
            ::= 18004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC1.MIB.txt
    Source location: CPQNIC-MIB::cpqNicRedundancyReduced.
    Source version and references

    Archived: 2026-10-19T00:22:08.785752+00:00.

  • Preserved circitor archive

    Module: CPQNIC-MIB

    Published definition
    cpqNicRedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqNicIfLogMapAdapterOKCount}
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Status Trap (18004)"
                 --#SUMMARY "Redundancy decreased by adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
            ::= 18004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB.mib
    Source location: CPQNIC-MIB::cpqNicRedundancyReduced.
    Source version and references

    Archived: 2026-10-19T00:22:16.786453+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQNIC-MIB

    Published definition
    cpqNicRedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqNicIfLogMapAdapterOKCount}
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "NIC Status Trap (18004)"
                 --#SUMMARY "Redundancy decreased by adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
                 --#STATE DEGRADED
                 --#SIMPLE_SEVERITY MAJOR
                 --#HWSTATUS_CATEGORY NETWORK
                 --#ACTION "Check the cables to the adapter and the Hub or Switch.  If no cable problems are found, the adapter, Hub, or Switch may need replacement."             
                 
            ::= 18004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB

    Related source files and packages:


    Source location: CPQNIC-MIB::cpqNicRedundancyReduced.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.096280+00:00.

  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNicRedundancyReduced TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqNicIfLogMapAdapterOKCount}
            DESCRIPTION
                "This trap will be sent any time a physical adapter in a
                 logical adapter group changes to the Failed condition, but
                 at least one physical adapter remains in the OK condition..
    
                 This can be caused by loss of link due to a cable being
                 removed from the adapter or the Hub or Switch.  Internal
                 adapter, Hub, or Switch failures can also cause this
                 condition.
    
                 User Action: Check the cables to the adapter and the Hub or
                 Switch.  If no cable problems are found, the adapter, Hub,
                 or Switch may need replacement."
    
                 --#TYPE "Status Trap"
                 --#SUMMARY "Redundancy decreased by adapter in slot %s, port %s."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY MAJOR
                 --#TIMEINDEX 99
            ::= 18004
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}

    Source data warning: This historical publication omits an explicitly reviewed standard root import. Exact original declarations and all numeric values are retained; the referenced RFC and IANA allocation establish only the missing standard namespace.

    · Download Compaq-Nic.mib.txt

    Related source files and packages:


    Source location: CPQNIC-MIB::cpqNicRedundancyReduced.
    Source version and references

    Archived: 2026-10-19T00:22:08.801046+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.5006 cpqScsi3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5007 cpqTape3PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5008 cpqTape3PhyDrvCleaningRequired00
1.3.6.1.4.1.232.0.5009 cpqTape3PhyDrvCleanTapeReplace00
1.3.6.1.4.1.232.0.5010 cpqTape3LibraryFailed00
1.3.6.1.4.1.232.0.5011 cpqTape3LibraryOkay00
1.3.6.1.4.1.232.0.5012 cpqTape3LibraryDegraded00
1.3.6.1.4.1.232.0.5013 cpqTape3LibraryDoorOpen00
1.3.6.1.4.1.232.0.5014 cpqTape3LibraryDoorClosed00
1.3.6.1.4.1.232.0.5015 cpqScsiCdLibraryStatusChange00
1.3.6.1.4.1.232.0.5016 cpqTape4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5017 cpqScsi4PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5018 cpqTapeLibraryStatusChange00
1.3.6.1.4.1.232.0.5019 cpqTape5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5020 cpqScsi5PhyDrvStatusChange00
1.3.6.1.4.1.232.0.5021 cpqScsi3LogDrvStatusChange00
1.3.6.1.4.1.232.0.5022 cpqSasPhyDrvStatusChange00
1.3.6.1.4.1.232.0.5023 cpqSasLogDrvStatusChange00
1.3.6.1.4.1.232.0.5025 cpqSas2TapeDrvStatusChange00
1.3.6.1.4.1.232.0.5026 cpqSasPhyDrvSSDWearStatusChange00
1.3.6.1.4.1.232.0.6001 cpqHe2CorrectableMemoryError00
1.3.6.1.4.1.232.0.6002 cpqHe2CorrectableMemoryLogDisabled00
1.3.6.1.4.1.232.0.6003 cpqHeThermalTempFailed00
1.3.6.1.4.1.232.0.6004 cpqHeThermalTempDegraded00
1.3.6.1.4.1.232.0.6005 cpqHeThermalTempOk00
1.3.6.1.4.1.232.0.6006 cpqHeThermalSystemFanFailed00
1.3.6.1.4.1.232.0.6007 cpqHeThermalSystemFanDegraded00
1.3.6.1.4.1.232.0.6008 cpqHeThermalSystemFanOk00
1.3.6.1.4.1.232.0.6009 cpqHeThermalCpuFanFailed00
1.3.6.1.4.1.232.0.6010 cpqHeThermalCpuFanOk00
1.3.6.1.4.1.232.0.6011 cpqHeAsrConfirmation00
1.3.6.1.4.1.232.0.6012 cpqHeThermalConfirmation00
1.3.6.1.4.1.232.0.6013 cpqHePostError00
1.3.6.1.4.1.232.0.6014 cpqHeFltTolPwrSupplyDegraded00
1.3.6.1.4.1.232.0.6015 cpqHe3CorrectableMemoryError00
1.3.6.1.4.1.232.0.6016 cpqHe3CorrectableMemoryLogDisabled00
1.3.6.1.4.1.232.0.6017 cpqHe3ThermalTempFailed00
1.3.6.1.4.1.232.0.6018 cpqHe3ThermalTempDegraded00
1.3.6.1.4.1.232.0.6019 cpqHe3ThermalTempOk00
1.3.6.1.4.1.232.0.6020 cpqHe3ThermalSystemFanFailed00
1.3.6.1.4.1.232.0.6021 cpqHe3ThermalSystemFanDegraded00
1.3.6.1.4.1.232.0.6022 cpqHe3ThermalSystemFanOk00
1.3.6.1.4.1.232.0.6023 cpqHe3ThermalCpuFanFailed00
1.3.6.1.4.1.232.0.6024 cpqHe3ThermalCpuFanOk00
1.3.6.1.4.1.232.0.6025 cpqHe3AsrConfirmation00
1.3.6.1.4.1.232.0.6026 cpqHe3ThermalConfirmation00
1.3.6.1.4.1.232.0.6027 cpqHe3PostError00
1.3.6.1.4.1.232.0.6028 cpqHe3FltTolPwrSupplyDegraded00
1.3.6.1.4.1.232.0.6029 cpqHe3CorrMemReplaceMemModule00
1.3.6.1.4.1.232.0.6030 cpqHe3FltTolPowerSupplyDegraded00