Reference record for OID 1.3.6.1.4.1.232.0.18005

Parent
1.3.6.1.4.1.232.0 (0)
Node code
18005
Node name
cpqNic2ConnectivityRestored
Numeric OID
1.3.6.1.4.1.232.0.18005
URN notation
urn:oid:1.3.6.1.4.1.232.0.18005
ASN.1 notation

{1 3 6 1 4 1 232 0 18005}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqNic2ConnectivityRestored(18005)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqNic2ConnectivityRestored(18005)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/18005
  • /ISO/Identified-Organization/6/1/4/1/232/0/18005
  • /ISO/3/6/1/4/1/232/0/18005
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqNic2ConnectivityRestored
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqNic2ConnectivityRestored
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqNic2ConnectivityRestored
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqNic2ConnectivityRestored
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqNic2ConnectivityRestored
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqNic2ConnectivityRestored
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqNic2ConnectivityRestored
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqNic2ConnectivityRestored
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqNic2ConnectivityRestored
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqNic2ConnectivityRestored
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqNic2ConnectivityRestored
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqNic2ConnectivityRestored
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqNic2ConnectivityRestored
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqNic2ConnectivityRestored
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqNic2ConnectivityRestored
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqNic2ConnectivityRestored
  • Additional combinations skipped.

Descriptions

cpqNic2ConnectivityRestored — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

This trap will be sent any time connectivity is restored to a logical adapter. This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User Action: None required.

Source records

cpqNic2ConnectivityRestored

Status in source: unspecified.

Names: cpqNic2ConnectivityRestored

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqNic2ConnectivityRestored",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqNicIfPhysAdapterSlot",
    ",",
    "cpqNicIfPhysAdapterPort",
    ",",
    "cpqSiServerSystemId",
    ",",
    "cpqNicIfPhysAdapterStatus",
    ",",
    "cpqSePciSlotBoardName",
    ",",
    "cpqNicIfPhysAdapterPartNumber",
    ",",
    "ipAdEntAddr",
    "}",
    "DESCRIPTION",
    "\"This trap will be sent any time connectivity is restored to a logical adapter. This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User Action: None required.\"",
    "::=",
    "18005"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqNicIfPhysAdapterSlot",
        "cpqNicIfPhysAdapterPort",
        "cpqSiServerSystemId",
        "cpqNicIfPhysAdapterStatus",
        "cpqSePciSlotBoardName",
        "cpqNicIfPhysAdapterPartNumber",
        "ipAdEntAddr"
      ]
    ],
    [
      "DESCRIPTION",
      "This trap will be sent any time connectivity is restored to a logical adapter. This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User Action: None required."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic2ConnectivityRestored TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr }
            DESCRIPTION
                "This trap will be sent any time connectivity is restored
                 to a logical adapter.  This occurs when the physical
                 adapter in a single adapter configuration returns to
                 the OK condition or at least one physical adapter
                 in a logical adapter group returns to the OK condition.
    
                 This can be caused by replacement of a faulty cable
                 or re-attaching a cable that was unplugged.
    
                 User Action: None required."
    
                 --#TYPE "NIC Connectivity Restored Trap (18005)"
                 --#SUMMARY "Connectivity is restored for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY INFORMATIONAL
                 --#TIMEINDEX 18
                 --#STATE OPERATIONAL
            ::= 18005
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC.MIB.txt
    Source location: CPQNIC-MIB::cpqNic2ConnectivityRestored.
    Source version and references

    Archived: 2026-10-19T00:22:08.785287+00:00.

  • Preserved mibdepot archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic2ConnectivityRestored TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr }
            DESCRIPTION
                "This trap will be sent any time connectivity is restored
                 to a logical adapter.  This occurs when the physical
                 adapter in a single adapter configuration returns to
                 the OK condition or at least one physical adapter
                 in a logical adapter group returns to the OK condition.
    
                 This can be caused by replacement of a faulty cable
                 or re-attaching a cable that was unplugged.
    
                 User Action: None required."
    
                 --#TYPE "NIC Connectivity Restored Trap"
                 --#SUMMARY "Connectivity is restored for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY INFORMATIONAL
                 --#TIMEINDEX 18
                 --#STATE OPERATIONAL
            ::= 18005
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC1.MIB.txt
    Source location: CPQNIC-MIB::cpqNic2ConnectivityRestored.
    Source version and references

    Archived: 2026-10-19T00:22:08.785752+00:00.

  • Preserved circitor archive

    Module: CPQNIC-MIB

    Published definition
    cpqNic2ConnectivityRestored TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr }
            DESCRIPTION
                "This trap will be sent any time connectivity is restored
                 to a logical adapter.  This occurs when the physical
                 adapter in a single adapter configuration returns to
                 the OK condition or at least one physical adapter
                 in a logical adapter group returns to the OK condition.
    
                 This can be caused by replacement of a faulty cable
                 or re-attaching a cable that was unplugged.
    
                 User Action: None required."
    
                 --#TYPE "NIC Connectivity Restored Trap (18005)"
                 --#SUMMARY "Connectivity is restored for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY INFORMATIONAL
                 --#TIMEINDEX 18
                 --#STATE OPERATIONAL
            ::= 18005
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB.mib
    Source location: CPQNIC-MIB::cpqNic2ConnectivityRestored.
    Source version and references

    Archived: 2026-10-19T00:22:16.786453+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQNIC-MIB

    Published definition
    cpqNic2ConnectivityRestored TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES { sysName, cpqHoTrapFlags, cpqNicIfPhysAdapterSlot,
                        cpqNicIfPhysAdapterPort, cpqSiServerSystemId,
                        cpqNicIfPhysAdapterStatus, cpqSePciSlotBoardName,
                        cpqNicIfPhysAdapterPartNumber, ipAdEntAddr }
            DESCRIPTION
                "This trap will be sent any time connectivity is restored
                 to a logical adapter.  This occurs when the physical
                 adapter in a single adapter configuration returns to
                 the OK condition or at least one physical adapter
                 in a logical adapter group returns to the OK condition.
    
                 This can be caused by replacement of a faulty cable
                 or re-attaching a cable that was unplugged.
    
                 User Action: None required."
    
                 --#TYPE "NIC Connectivity Restored Trap (18005)"
                 --#SUMMARY "Connectivity is restored for adapter in slot %d, port %d."
                 --#ARGUMENTS {2, 3}
                 --#SEVERITY INFORMATIONAL
                 --#TIMEINDEX 18
                 --#STATE OPERATIONAL
                 --#SIMPLE_SEVERITY OK
                 --#HWSTATUS_CATEGORY NETWORK
                 
            ::= 18005
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'sysName', 'ipAdEntAddr'], 'CPQSINFO-MIB': ['cpqSiServerSystemId'], 'CPQSTDEQ-MIB': ['cpqSePciSlotBoardName']}
    · Download CPQNIC-MIB

    Related source files and packages:


    Source location: CPQNIC-MIB::cpqNic2ConnectivityRestored.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.096280+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.1001 cpqSeCpuThresholdPassed00
1.3.6.1.4.1.232.0.1002 cpqSePCCardThermalDegraded00
1.3.6.1.4.1.232.0.1003 cpqSePCCardThermalFailure00
1.3.6.1.4.1.232.0.1004 cpqSePCCardThermalSafe00
1.3.6.1.4.1.232.0.1005 cpqSe2CpuThresholdPassed00
1.3.6.1.4.1.232.0.1006 cpqSeCpuStatusChange00
1.3.6.1.4.1.232.0.1007 cpqSeCpuPowerPodstatusChange00
1.3.6.1.4.1.232.0.1008 cpqSeUSBStorageDeviceAttached00
1.3.6.1.4.1.232.0.1009 cpqSeUSBStorageDeviceRemoved00
1.3.6.1.4.1.232.0.1010 cpqSeUSBStorageDeviceReadErrorOccurred00
1.3.6.1.4.1.232.0.1011 cpqSeUSBStorageDeviceWriteErrorOccurred00
1.3.6.1.4.1.232.0.1012 cpqSeUSBStorageDeviceRedundancyLost00
1.3.6.1.4.1.232.0.1013 cpqSeUSBStorageDeviceRedundancyRestored00
1.3.6.1.4.1.232.0.1014 cpqSeUSBStorageDeviceSyncFailed00
1.3.6.1.4.1.232.0.1015 cpqSePCIeDiskTemperatureFailed00
1.3.6.1.4.1.232.0.1016 cpqSePCIeDiskTemperatureOk00
1.3.6.1.4.1.232.0.1017 cpqSePCIeDiskConditionChange00
1.3.6.1.4.1.232.0.1018 cpqSePCIeDiskWearStatusChange00
1.3.6.1.4.1.232.0.1019 cpqSePciDeviceAddedOrPoweredOn00
1.3.6.1.4.1.232.0.1020 cpqSePciDeviceRemovedOrPoweredOff00
1.3.6.1.4.1.232.0.1021 cpqSeNVMeSecureEraseFailed00
1.3.6.1.4.1.232.0.1022 cpqSePcieTrainingFailed00
1.3.6.1.4.1.232.0.1023 cpqSePciResetFail00
1.3.6.1.4.1.232.0.1024 cpqSeSecureBootAuthFail00
1.3.6.1.4.1.232.0.1025 cpqSeSecureBootCertAuthFail00
1.3.6.1.4.1.232.0.1026 cpqSeCpuUncorrectableError00
1.3.6.1.4.1.232.0.1027 cpqSeInternalCpuError00
1.3.6.1.4.1.232.0.2001 cpqSiHoodRemoved00
1.3.6.1.4.1.232.0.2002 cpqSiMonitorConditionOK00
1.3.6.1.4.1.232.0.2003 cpqSiMonitorConditionDegraded00
1.3.6.1.4.1.232.0.2004 cpqSiMonitorConditionFailed00
1.3.6.1.4.1.232.0.2005 cpqSiCorrMemErrStatusDegraded00
1.3.6.1.4.1.232.0.2006 cpqSiCorrMemErrStatusOk00
1.3.6.1.4.1.232.0.2007 cpqSiMemConfigChange00
1.3.6.1.4.1.232.0.2008 cpqSiHotPlugSlotBoardRemoved00
1.3.6.1.4.1.232.0.2009 cpqSiHotPlugSlotBoardInserted00
1.3.6.1.4.1.232.0.2010 cpqSiHotPlugSlotPowerUpFailed00
1.3.6.1.4.1.232.0.2011 cpqSiSysBatteryFailure00
1.3.6.1.4.1.232.0.2012 cpqSiSysBatteryChargingDegraded00
1.3.6.1.4.1.232.0.2013 cpqSiSysBatteryCalibrationError00
1.3.6.1.4.1.232.0.2014 cpqSiIntrusionInstalled00
1.3.6.1.4.1.232.0.2015 cpqSiIntrusionRemoved00
1.3.6.1.4.1.232.0.2016 cpqSiHoodReplaced00
1.3.6.1.4.1.232.0.2017 cpqSiHoodRemovedOnPowerOff00
1.3.6.1.4.1.232.0.2018 cpqSiSysTelemetryThresholdAlert00
1.3.6.1.4.1.232.0.3001 cpqDa2LogDrvStatusChange00
1.3.6.1.4.1.232.0.3002 cpqDa2SpareStatusChange00
1.3.6.1.4.1.232.0.3003 cpqDa2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3004 cpqDa2PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3005 cpqDa2AccelStatusChange00