Reference record for OID 1.3.6.1.4.1.232.0.22022

Parent
1.3.6.1.4.1.232.0 (0)
Node code
22022
Node name
cpqRackServerPowerOnFailedNotRedundant
Numeric OID
1.3.6.1.4.1.232.0.22022
URN notation
urn:oid:1.3.6.1.4.1.232.0.22022
ASN.1 notation

{1 3 6 1 4 1 232 0 22022}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqRackServerPowerOnFailedNotRedundant(22022)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/22022
  • /ISO/Identified-Organization/6/1/4/1/232/0/22022
  • /ISO/3/6/1/4/1/232/0/22022
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqRackServerPowerOnFailedNotRedundant
  • Additional combinations skipped.

Descriptions

cpqRackServerPowerOnFailedNotRedundant — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User Action: Check power connections or add power supplies.

Source records

cpqRackServerPowerOnFailedNotRedundant

Status in source: unspecified.

Names: cpqRackServerPowerOnFailedNotRedundant

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqRackServerPowerOnFailedNotRedundant",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqRackName",
    ",",
    "cpqRackUid",
    ",",
    "cpqRackServerBladeEnclosureName",
    ",",
    "cpqRackServerBladePosition",
    ",",
    "cpqRackServerBladeSparePartNumber",
    ",",
    "cpqRackCommonEnclosureSerialNum",
    ",",
    "cpqRackCommonEnclosureTrapSequenceNum",
    "}",
    "DESCRIPTION",
    "\"Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User Action: Check power connections or add power supplies.\"",
    "::=",
    "22022"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqRackName",
        "cpqRackUid",
        "cpqRackServerBladeEnclosureName",
        "cpqRackServerBladePosition",
        "cpqRackServerBladeSparePartNumber",
        "cpqRackCommonEnclosureSerialNum",
        "cpqRackCommonEnclosureTrapSequenceNum"
      ]
    ],
    [
      "DESCRIPTION",
      "Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User Action: Check power connections or add power supplies."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQRACK-MIB

    Published definition
    cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackServerBladeEnclosureName,
                         cpqRackServerBladePosition,
                         cpqRackServerBladeSparePartNumber,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "Server power on prevented to preserve redundancy.
    
                There is not enough power to power on the server blade and
                maintain redundancy for the other blades in the enclosure.
    
                User Action: Check power connections or add power supplies."
    
            --#TYPE "Server power on prevented to preserve redundancy (22022)"
            --#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
            --#ARGUMENTS {5, 4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
    
            ::= 22022
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK.MIB.txt
    Source location: CPQRACK-MIB::cpqRackServerPowerOnFailedNotRedundant.
    Source version and references

    Archived: 2026-10-19T00:22:08.787249+00:00.

  • Preserved circitor archive

    Module: CPQRACK-MIB

    Published definition
    cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackServerBladeEnclosureName,
                         cpqRackServerBladePosition,
                         cpqRackServerBladeSparePartNumber,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "Server power on prevented to preserve redundancy.
    
                There is not enough power to power on the server blade and
                maintain redundancy for the other blades in the enclosure.
    
                User Action: Check power connections or add power supplies."
    
            --#TYPE "Server power on prevented to preserve redundancy (22022)"
            --#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
            --#ARGUMENTS {5, 4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
    
            ::= 22022
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB.mib
    Source location: CPQRACK-MIB::cpqRackServerPowerOnFailedNotRedundant.
    Source version and references

    Archived: 2026-10-19T00:22:16.793075+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQRACK-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQRACK-MIB

    Published definition
    cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackServerBladeEnclosureName,
                         cpqRackServerBladePosition,
                         cpqRackServerBladeSparePartNumber,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "Server power on prevented to preserve redundancy.
    
                There is not enough power to power on the server blade and
                maintain redundancy for the other blades in the enclosure.
    
                User Action: Check power connections or add power supplies."
    
            --#TYPE "Server power on prevented to preserve redundancy (22022)"
            --#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
            --#ARGUMENTS {5, 4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY POWER
            --#ACTION "Check the power connections for problems, then add power supplies if necessary."
            
            ::= 22022
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoOsType', 'cpqHoVersion'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB

    Related source files and packages:


    Source location: CPQRACK-MIB::cpqRackServerPowerOnFailedNotRedundant.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.143420+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQRACK-MIB

    Published definition
    cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName,
                         cpqHoTrapFlags,
                         cpqRackName,
                         cpqRackUid,
                         cpqRackServerBladeEnclosureName,
                         cpqRackServerBladePosition,
                         cpqRackServerBladeSparePartNumber,
                         cpqRackCommonEnclosureSerialNum,
                         cpqRackCommonEnclosureTrapSequenceNum }
            DESCRIPTION
               "Server power on prevented to preserve redundancy.
    
                There is not enough power to power on the server blade and
                maintain redundancy for the other blades in the enclosure.
    
                User Action: Check power connections or add power supplies."
    
            --#TYPE "Server power on prevented to preserve redundancy (22022)"
            --#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
            --#ARGUMENTS {5, 4, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#STATE NONOPERATIONAL
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY POWER
            --#ACTION "Check the power connections for problems, then add power supplies if necessary."
            
            ::= 22022
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags', 'cpqHoOsType', 'cpqHoVersion'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQRACK-MIB

    Related source files and packages:


    Source location: CPQRACK-MIB::cpqRackServerPowerOnFailedNotRedundant.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.206277+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.1001 cpqSeCpuThresholdPassed00
1.3.6.1.4.1.232.0.1002 cpqSePCCardThermalDegraded00
1.3.6.1.4.1.232.0.1003 cpqSePCCardThermalFailure00
1.3.6.1.4.1.232.0.1004 cpqSePCCardThermalSafe00
1.3.6.1.4.1.232.0.1005 cpqSe2CpuThresholdPassed00
1.3.6.1.4.1.232.0.1006 cpqSeCpuStatusChange00
1.3.6.1.4.1.232.0.1007 cpqSeCpuPowerPodstatusChange00
1.3.6.1.4.1.232.0.1008 cpqSeUSBStorageDeviceAttached00
1.3.6.1.4.1.232.0.1009 cpqSeUSBStorageDeviceRemoved00
1.3.6.1.4.1.232.0.1010 cpqSeUSBStorageDeviceReadErrorOccurred00
1.3.6.1.4.1.232.0.1011 cpqSeUSBStorageDeviceWriteErrorOccurred00
1.3.6.1.4.1.232.0.1012 cpqSeUSBStorageDeviceRedundancyLost00
1.3.6.1.4.1.232.0.1013 cpqSeUSBStorageDeviceRedundancyRestored00
1.3.6.1.4.1.232.0.1014 cpqSeUSBStorageDeviceSyncFailed00
1.3.6.1.4.1.232.0.1015 cpqSePCIeDiskTemperatureFailed00
1.3.6.1.4.1.232.0.1016 cpqSePCIeDiskTemperatureOk00
1.3.6.1.4.1.232.0.1017 cpqSePCIeDiskConditionChange00
1.3.6.1.4.1.232.0.1018 cpqSePCIeDiskWearStatusChange00
1.3.6.1.4.1.232.0.1019 cpqSePciDeviceAddedOrPoweredOn00
1.3.6.1.4.1.232.0.1020 cpqSePciDeviceRemovedOrPoweredOff00
1.3.6.1.4.1.232.0.1021 cpqSeNVMeSecureEraseFailed00
1.3.6.1.4.1.232.0.1022 cpqSePcieTrainingFailed00
1.3.6.1.4.1.232.0.1023 cpqSePciResetFail00
1.3.6.1.4.1.232.0.1024 cpqSeSecureBootAuthFail00
1.3.6.1.4.1.232.0.1025 cpqSeSecureBootCertAuthFail00
1.3.6.1.4.1.232.0.1026 cpqSeCpuUncorrectableError00
1.3.6.1.4.1.232.0.1027 cpqSeInternalCpuError00
1.3.6.1.4.1.232.0.2001 cpqSiHoodRemoved00
1.3.6.1.4.1.232.0.2002 cpqSiMonitorConditionOK00
1.3.6.1.4.1.232.0.2003 cpqSiMonitorConditionDegraded00
1.3.6.1.4.1.232.0.2004 cpqSiMonitorConditionFailed00
1.3.6.1.4.1.232.0.2005 cpqSiCorrMemErrStatusDegraded00
1.3.6.1.4.1.232.0.2006 cpqSiCorrMemErrStatusOk00
1.3.6.1.4.1.232.0.2007 cpqSiMemConfigChange00
1.3.6.1.4.1.232.0.2008 cpqSiHotPlugSlotBoardRemoved00
1.3.6.1.4.1.232.0.2009 cpqSiHotPlugSlotBoardInserted00
1.3.6.1.4.1.232.0.2010 cpqSiHotPlugSlotPowerUpFailed00
1.3.6.1.4.1.232.0.2011 cpqSiSysBatteryFailure00
1.3.6.1.4.1.232.0.2012 cpqSiSysBatteryChargingDegraded00
1.3.6.1.4.1.232.0.2013 cpqSiSysBatteryCalibrationError00
1.3.6.1.4.1.232.0.2014 cpqSiIntrusionInstalled00
1.3.6.1.4.1.232.0.2015 cpqSiIntrusionRemoved00
1.3.6.1.4.1.232.0.2016 cpqSiHoodReplaced00
1.3.6.1.4.1.232.0.2017 cpqSiHoodRemovedOnPowerOff00
1.3.6.1.4.1.232.0.2018 cpqSiSysTelemetryThresholdAlert00
1.3.6.1.4.1.232.0.3001 cpqDa2LogDrvStatusChange00
1.3.6.1.4.1.232.0.3002 cpqDa2SpareStatusChange00
1.3.6.1.4.1.232.0.3003 cpqDa2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3004 cpqDa2PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3005 cpqDa2AccelStatusChange00