Reference record for OID 1.3.6.1.4.1.232.0.3031

Parent
1.3.6.1.4.1.232.0 (0)
Node code
3031
Node name
cpqDa2TapeLibraryStatusChange
Numeric OID
1.3.6.1.4.1.232.0.3031
URN notation
urn:oid:1.3.6.1.4.1.232.0.3031
ASN.1 notation

{1 3 6 1 4 1 232 0 3031}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqDa2TapeLibraryStatusChange(3031)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/3031
  • /ISO/Identified-Organization/6/1/4/1/232/0/3031
  • /ISO/3/6/1/4/1/232/0/3031
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqDa2TapeLibraryStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqDa2TapeLibraryStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqDa2TapeLibraryStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqDa2TapeLibraryStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqDa2TapeLibraryStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqDa2TapeLibraryStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqDa2TapeLibraryStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqDa2TapeLibraryStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqDa2TapeLibraryStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqDa2TapeLibraryStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqDa2TapeLibraryStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqDa2TapeLibraryStatusChange
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqDa2TapeLibraryStatusChange
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqDa2TapeLibraryStatusChange
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqDa2TapeLibraryStatusChange
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqDa2TapeLibraryStatusChange
  • Additional combinations skipped.

Descriptions

cpqDa2TapeLibraryStatusChange — MIBdepot

Tape Library Status Change. This trap signifies that the agent has detected a change in the status of a Compaq tape library. The variable cpqDaTapeLibraryStatus indicates the current tape library status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library. User Action: If the tape library is failed, check the tape library front panel.

cpqDa2TapeLibraryStatusChange — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Tape Library Status Change. This trap signifies that the agent has detected a change in the status of a tape library. The variable cpqDaTapeLibraryStatus indicates the current tape library status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library. User Action: If the tape library is failed, check the tape library front panel.

Source records

cpqDa2TapeLibraryStatusChange

Status in source: unspecified.

Names: cpqDa2TapeLibraryStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqDa2TapeLibraryStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqDaTapeLibraryCntlrIndex",
    ",",
    "cpqDaTapeLibraryScsiBus",
    ",",
    "cpqDaTapeLibraryScsiTarget",
    ",",
    "cpqDaTapeLibraryScsiLun",
    ",",
    "cpqDaTapeLibraryModel",
    ",",
    "cpqDaTapeLibraryFWRev",
    ",",
    "cpqDaTapeLibrarySerialNumber",
    ",",
    "cpqDaTapeLibraryStatus",
    "}",
    "DESCRIPTION",
    "\"Tape Library Status Change. This trap signifies that the agent has detected a change in the status of a Compaq tape library. The variable cpqDaTapeLibraryStatus indicates the current tape library status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library. User Action: If the tape library is failed, check the tape library front panel.\"",
    "::=",
    "3031"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqDaTapeLibraryCntlrIndex",
        "cpqDaTapeLibraryScsiBus",
        "cpqDaTapeLibraryScsiTarget",
        "cpqDaTapeLibraryScsiLun",
        "cpqDaTapeLibraryModel",
        "cpqDaTapeLibraryFWRev",
        "cpqDaTapeLibrarySerialNumber",
        "cpqDaTapeLibraryStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Tape Library Status Change. This trap signifies that the agent has detected a change in the status of a Compaq tape library. The variable cpqDaTapeLibraryStatus indicates the current tape library status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library. User Action: If the tape library is failed, check the tape library front panel."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQIDA-MIB

    Published definition
    cpqDa2TapeLibraryStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaTapeLibraryCntlrIndex,
                         cpqDaTapeLibraryScsiBus, cpqDaTapeLibraryScsiTarget,
                         cpqDaTapeLibraryScsiLun, cpqDaTapeLibraryModel,
                         cpqDaTapeLibraryFWRev, cpqDaTapeLibrarySerialNumber,
                         cpqDaTapeLibraryStatus}
            DESCRIPTION
                "Tape Library Status Change.
    
                This trap signifies that the agent has detected a change in
                the status of a Compaq tape library.  The variable
                cpqDaTapeLibraryStatus indicates the current tape library
                status.  The variable cpqDaTapeLibraryScsiTarget indicates
                the SCSI ID of the tape library.
    
                User Action: If the tape library is failed, check the tape
                library front panel."
    
    
            --#TYPE "Tape Library Status Change"
            --#SUMMARY "Status is now %d for the tape library."
            --#ARGUMENTS {9}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
    
            ::= 3031
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA2.MIB.txt
    Source location: CPQIDA-MIB::cpqDa2TapeLibraryStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.783828+00:00.

cpqDa2TapeLibraryStatusChange

Status in source: unspecified.

Names: cpqDa2TapeLibraryStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqDa2TapeLibraryStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqDaTapeLibraryCntlrIndex",
    ",",
    "cpqDaTapeLibraryScsiBus",
    ",",
    "cpqDaTapeLibraryScsiTarget",
    ",",
    "cpqDaTapeLibraryScsiLun",
    ",",
    "cpqDaTapeLibraryModel",
    ",",
    "cpqDaTapeLibraryFWRev",
    ",",
    "cpqDaTapeLibrarySerialNumber",
    ",",
    "cpqDaTapeLibraryStatus",
    "}",
    "DESCRIPTION",
    "\"Tape Library Status Change. This trap signifies that the agent has detected a change in the status of a tape library. The variable cpqDaTapeLibraryStatus indicates the current tape library status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library. User Action: If the tape library is failed, check the tape library front panel.\"",
    "::=",
    "3031"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqDaTapeLibraryCntlrIndex",
        "cpqDaTapeLibraryScsiBus",
        "cpqDaTapeLibraryScsiTarget",
        "cpqDaTapeLibraryScsiLun",
        "cpqDaTapeLibraryModel",
        "cpqDaTapeLibraryFWRev",
        "cpqDaTapeLibrarySerialNumber",
        "cpqDaTapeLibraryStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Tape Library Status Change. This trap signifies that the agent has detected a change in the status of a tape library. The variable cpqDaTapeLibraryStatus indicates the current tape library status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library. User Action: If the tape library is failed, check the tape library front panel."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQIDA-MIB

    Published definition
    cpqDa2TapeLibraryStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaTapeLibraryCntlrIndex,
                         cpqDaTapeLibraryScsiBus, cpqDaTapeLibraryScsiTarget,
                         cpqDaTapeLibraryScsiLun, cpqDaTapeLibraryModel,
                         cpqDaTapeLibraryFWRev, cpqDaTapeLibrarySerialNumber,
                         cpqDaTapeLibraryStatus}
            DESCRIPTION
                "Tape Library Status Change.
    
                This trap signifies that the agent has detected a change in
                the status of a tape library.  The variable
                cpqDaTapeLibraryStatus indicates the current tape library
                status.  The variable cpqDaTapeLibraryScsiTarget indicates
                the SCSI ID of the tape library.
    
                User Action: If the tape library is failed, check the tape
                library front panel."
    
    
            --#TYPE "Tape Library Status Change (3031)"
            --#SUMMARY "Status is now %d for the tape library."
            --#ARGUMENTS {9}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
    
            ::= 3031
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA.MIB.txt
    Source location: CPQIDA-MIB::cpqDa2TapeLibraryStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.781630+00:00.

  • Preserved circitor archive

    Module: CPQIDA-MIB

    Published definition
    cpqDa2TapeLibraryStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaTapeLibraryCntlrIndex,
                         cpqDaTapeLibraryScsiBus, cpqDaTapeLibraryScsiTarget,
                         cpqDaTapeLibraryScsiLun, cpqDaTapeLibraryModel,
                         cpqDaTapeLibraryFWRev, cpqDaTapeLibrarySerialNumber,
                         cpqDaTapeLibraryStatus}
            DESCRIPTION
                "Tape Library Status Change.
    
                This trap signifies that the agent has detected a change in
                the status of a tape library.  The variable
                cpqDaTapeLibraryStatus indicates the current tape library
                status.  The variable cpqDaTapeLibraryScsiTarget indicates
                the SCSI ID of the tape library.
    
                User Action: If the tape library is failed, check the tape
                library front panel."
    
    
            --#TYPE "Tape Library Status Change (3031)"
            --#SUMMARY "Status is now %d for the tape library."
            --#ARGUMENTS {9}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
    
            ::= 3031
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA-MIB.mib
    Source location: CPQIDA-MIB::cpqDa2TapeLibraryStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:16.779739+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQIDA-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQIDA-MIB

    Published definition
    cpqDa2TapeLibraryStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaTapeLibraryCntlrIndex,
                         cpqDaTapeLibraryScsiBus, cpqDaTapeLibraryScsiTarget,
                         cpqDaTapeLibraryScsiLun, cpqDaTapeLibraryModel,
                         cpqDaTapeLibraryFWRev, cpqDaTapeLibrarySerialNumber,
                         cpqDaTapeLibraryStatus}
            DESCRIPTION
                "Tape Library Status Change.
    
                This trap signifies that the agent has detected a change in
                the status of a tape library.  The variable
                cpqDaTapeLibraryStatus indicates the current tape library
                status.  The variable cpqDaTapeLibraryScsiTarget indicates
                the SCSI ID of the tape library.
    
                User Action: If the tape library is failed, check the tape
                library front panel."
    
    
            --#TYPE "Tape Library Status Change (3031)"
            --#SUMMARY "Status is now %d for the tape library."
            --#ARGUMENTS {9}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
    
            ::= 3031
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA-MIB

    Related source files and packages:


    Source location: CPQIDA-MIB::cpqDa2TapeLibraryStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.136420+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQIDA-MIB

    Published definition
    cpqDa2TapeLibraryStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaTapeLibraryCntlrIndex,
                         cpqDaTapeLibraryScsiBus, cpqDaTapeLibraryScsiTarget,
                         cpqDaTapeLibraryScsiLun, cpqDaTapeLibraryModel,
                         cpqDaTapeLibraryFWRev, cpqDaTapeLibrarySerialNumber,
                         cpqDaTapeLibraryStatus}
            DESCRIPTION
                "Tape Library Status Change.
    
                This trap signifies that the agent has detected a change in
                the status of a tape library.  The variable
                cpqDaTapeLibraryStatus indicates the current tape library
                status.  The variable cpqDaTapeLibraryScsiTarget indicates
                the SCSI ID of the tape library.
    
                User Action: If the tape library is failed, check the tape
                library front panel."
    
    
            --#TYPE "Tape Library Status Change (3031)"
            --#SUMMARY "Status is now %d for the tape library."
            --#ARGUMENTS {9}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
    
            ::= 3031
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA-MIB

    Related source files and packages:


    Source location: CPQIDA-MIB::cpqDa2TapeLibraryStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.378273+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.1001 cpqSeCpuThresholdPassed00
1.3.6.1.4.1.232.0.1002 cpqSePCCardThermalDegraded00
1.3.6.1.4.1.232.0.1003 cpqSePCCardThermalFailure00
1.3.6.1.4.1.232.0.1004 cpqSePCCardThermalSafe00
1.3.6.1.4.1.232.0.1005 cpqSe2CpuThresholdPassed00
1.3.6.1.4.1.232.0.1006 cpqSeCpuStatusChange00
1.3.6.1.4.1.232.0.1007 cpqSeCpuPowerPodstatusChange00
1.3.6.1.4.1.232.0.1008 cpqSeUSBStorageDeviceAttached00
1.3.6.1.4.1.232.0.1009 cpqSeUSBStorageDeviceRemoved00
1.3.6.1.4.1.232.0.1010 cpqSeUSBStorageDeviceReadErrorOccurred00
1.3.6.1.4.1.232.0.1011 cpqSeUSBStorageDeviceWriteErrorOccurred00
1.3.6.1.4.1.232.0.1012 cpqSeUSBStorageDeviceRedundancyLost00
1.3.6.1.4.1.232.0.1013 cpqSeUSBStorageDeviceRedundancyRestored00
1.3.6.1.4.1.232.0.1014 cpqSeUSBStorageDeviceSyncFailed00
1.3.6.1.4.1.232.0.1015 cpqSePCIeDiskTemperatureFailed00
1.3.6.1.4.1.232.0.1016 cpqSePCIeDiskTemperatureOk00
1.3.6.1.4.1.232.0.1017 cpqSePCIeDiskConditionChange00
1.3.6.1.4.1.232.0.1018 cpqSePCIeDiskWearStatusChange00
1.3.6.1.4.1.232.0.1019 cpqSePciDeviceAddedOrPoweredOn00
1.3.6.1.4.1.232.0.1020 cpqSePciDeviceRemovedOrPoweredOff00
1.3.6.1.4.1.232.0.1021 cpqSeNVMeSecureEraseFailed00
1.3.6.1.4.1.232.0.1022 cpqSePcieTrainingFailed00
1.3.6.1.4.1.232.0.1023 cpqSePciResetFail00
1.3.6.1.4.1.232.0.1024 cpqSeSecureBootAuthFail00
1.3.6.1.4.1.232.0.1025 cpqSeSecureBootCertAuthFail00
1.3.6.1.4.1.232.0.1026 cpqSeCpuUncorrectableError00
1.3.6.1.4.1.232.0.1027 cpqSeInternalCpuError00
1.3.6.1.4.1.232.0.2001 cpqSiHoodRemoved00
1.3.6.1.4.1.232.0.2002 cpqSiMonitorConditionOK00
1.3.6.1.4.1.232.0.2003 cpqSiMonitorConditionDegraded00
1.3.6.1.4.1.232.0.2004 cpqSiMonitorConditionFailed00
1.3.6.1.4.1.232.0.2005 cpqSiCorrMemErrStatusDegraded00
1.3.6.1.4.1.232.0.2006 cpqSiCorrMemErrStatusOk00
1.3.6.1.4.1.232.0.2007 cpqSiMemConfigChange00
1.3.6.1.4.1.232.0.2008 cpqSiHotPlugSlotBoardRemoved00
1.3.6.1.4.1.232.0.2009 cpqSiHotPlugSlotBoardInserted00
1.3.6.1.4.1.232.0.2010 cpqSiHotPlugSlotPowerUpFailed00
1.3.6.1.4.1.232.0.2011 cpqSiSysBatteryFailure00
1.3.6.1.4.1.232.0.2012 cpqSiSysBatteryChargingDegraded00
1.3.6.1.4.1.232.0.2013 cpqSiSysBatteryCalibrationError00
1.3.6.1.4.1.232.0.2014 cpqSiIntrusionInstalled00
1.3.6.1.4.1.232.0.2015 cpqSiIntrusionRemoved00
1.3.6.1.4.1.232.0.2016 cpqSiHoodReplaced00
1.3.6.1.4.1.232.0.2017 cpqSiHoodRemovedOnPowerOff00
1.3.6.1.4.1.232.0.2018 cpqSiSysTelemetryThresholdAlert00
1.3.6.1.4.1.232.0.3001 cpqDa2LogDrvStatusChange00
1.3.6.1.4.1.232.0.3002 cpqDa2SpareStatusChange00
1.3.6.1.4.1.232.0.3003 cpqDa2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3004 cpqDa2PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3005 cpqDa2AccelStatusChange00