Reference record for OID 1.3.6.1.4.1.232.0.3046

Parent
1.3.6.1.4.1.232.0 (0)
Node code
3046
Node name
cpqDa7PhyDrvStatusChange
Numeric OID
1.3.6.1.4.1.232.0.3046
URN notation
urn:oid:1.3.6.1.4.1.232.0.3046
ASN.1 notation

{1 3 6 1 4 1 232 0 3046}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqDa7PhyDrvStatusChange(3046)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/3046
  • /ISO/Identified-Organization/6/1/4/1/232/0/3046
  • /ISO/3/6/1/4/1/232/0/3046
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqDa7PhyDrvStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqDa7PhyDrvStatusChange
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqDa7PhyDrvStatusChange
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqDa7PhyDrvStatusChange
  • Additional combinations skipped.

Descriptions

cpqDa7PhyDrvStatusChange — Circitor, MIBdepot

Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive.

cpqDa7PhyDrvStatusChange — HPE networking MIB copies (LibreNMS/Observium Community)

Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)', replace the drive.

cpqDa7PhyDrvStatusChange — HPE networking MIB copies (LibreNMS/Observium Community)

Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is `failed(3)`, `predictiveFailure(4)`, `ssdWearOut(8)`, or `notAuthenticated(9)`, replace the drive.

Source records

cpqDa7PhyDrvStatusChange

Status in source: unspecified.

Names: cpqDa7PhyDrvStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqDa7PhyDrvStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqDaCntlrHwLocation",
    ",",
    "cpqDaPhyDrvCntlrIndex",
    ",",
    "cpqDaPhyDrvIndex",
    ",",
    "cpqDaPhyDrvLocationString",
    ",",
    "cpqDaPhyDrvType",
    ",",
    "cpqDaPhyDrvModel",
    ",",
    "cpqDaPhyDrvFWRev",
    ",",
    "cpqDaPhyDrvSerialNum",
    ",",
    "cpqDaPhyDrvFailureCode",
    ",",
    "cpqDaPhyDrvStatus",
    ",",
    "cpqDaPhyDrvBusNumber",
    "}",
    "DESCRIPTION",
    "\"Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive.\"",
    "::=",
    "3046"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqDaCntlrHwLocation",
        "cpqDaPhyDrvCntlrIndex",
        "cpqDaPhyDrvIndex",
        "cpqDaPhyDrvLocationString",
        "cpqDaPhyDrvType",
        "cpqDaPhyDrvModel",
        "cpqDaPhyDrvFWRev",
        "cpqDaPhyDrvSerialNum",
        "cpqDaPhyDrvFailureCode",
        "cpqDaPhyDrvStatus",
        "cpqDaPhyDrvBusNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQIDA-MIB

    Published definition
    cpqDa7PhyDrvStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
                         cpqDaPhyDrvCntlrIndex, cpqDaPhyDrvIndex,
                         cpqDaPhyDrvLocationString, cpqDaPhyDrvType,
                         cpqDaPhyDrvModel, cpqDaPhyDrvFWRev, cpqDaPhyDrvSerialNum,
                         cpqDaPhyDrvFailureCode, cpqDaPhyDrvStatus,
                         cpqDaPhyDrvBusNumber }
            DESCRIPTION
                "Physical Drive Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of a drive array physical drive.  The variable
                 cpaDaPhyDrvStatus indicates the current physical drive status.
    
                 User Action: If the physical drive status is failed(3) or
                 predictiveFailure(4), replace the drive."
    
            --#TYPE "Physical Drive Status Change (3046)"
            --#SUMMARY "Physical Drive Status is now %d."
            --#ARGUMENTS {11}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
    
            ::= 3046
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA.MIB.txt
    Source location: CPQIDA-MIB::cpqDa7PhyDrvStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.781630+00:00.

  • Preserved circitor archive

    Module: CPQIDA-MIB

    Published definition
    cpqDa7PhyDrvStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
                         cpqDaPhyDrvCntlrIndex, cpqDaPhyDrvIndex,
                         cpqDaPhyDrvLocationString, cpqDaPhyDrvType,
                         cpqDaPhyDrvModel, cpqDaPhyDrvFWRev, cpqDaPhyDrvSerialNum,
                         cpqDaPhyDrvFailureCode, cpqDaPhyDrvStatus,
                         cpqDaPhyDrvBusNumber }
            DESCRIPTION
                "Physical Drive Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of a drive array physical drive.  The variable
                 cpaDaPhyDrvStatus indicates the current physical drive status.
    
                 User Action: If the physical drive status is failed(3) or
                 predictiveFailure(4), replace the drive."
    
            --#TYPE "Physical Drive Status Change (3046)"
            --#SUMMARY "Physical Drive Status is now %d."
            --#ARGUMENTS {11}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
    
            ::= 3046
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA-MIB.mib
    Source location: CPQIDA-MIB::cpqDa7PhyDrvStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:16.779739+00:00.

cpqDa7PhyDrvStatusChange

Status in source: unspecified.

Names: cpqDa7PhyDrvStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqDa7PhyDrvStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqDaCntlrHwLocation",
    ",",
    "cpqDaPhyDrvCntlrIndex",
    ",",
    "cpqDaPhyDrvIndex",
    ",",
    "cpqDaPhyDrvLocationString",
    ",",
    "cpqDaPhyDrvType",
    ",",
    "cpqDaPhyDrvModel",
    ",",
    "cpqDaPhyDrvFWRev",
    ",",
    "cpqDaPhyDrvSerialNum",
    ",",
    "cpqDaPhyDrvFailureCode",
    ",",
    "cpqDaPhyDrvStatus",
    ",",
    "cpqDaPhyDrvBusNumber",
    "}",
    "DESCRIPTION",
    "\"Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)', replace the drive.\"",
    "::=",
    "3046"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqDaCntlrHwLocation",
        "cpqDaPhyDrvCntlrIndex",
        "cpqDaPhyDrvIndex",
        "cpqDaPhyDrvLocationString",
        "cpqDaPhyDrvType",
        "cpqDaPhyDrvModel",
        "cpqDaPhyDrvFWRev",
        "cpqDaPhyDrvSerialNum",
        "cpqDaPhyDrvFailureCode",
        "cpqDaPhyDrvStatus",
        "cpqDaPhyDrvBusNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)', replace the drive."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: CPQIDA-MIB

    Vendor MIB copy from the LibreNMS archive. HPE networking support.

    Module: CPQIDA-MIB

    Published definition
    cpqDa7PhyDrvStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
                         cpqDaPhyDrvCntlrIndex, cpqDaPhyDrvIndex,
                         cpqDaPhyDrvLocationString, cpqDaPhyDrvType,
                         cpqDaPhyDrvModel, cpqDaPhyDrvFWRev, cpqDaPhyDrvSerialNum,
                         cpqDaPhyDrvFailureCode, cpqDaPhyDrvStatus,
                         cpqDaPhyDrvBusNumber }
            DESCRIPTION
                "Physical Drive Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of a drive array physical drive.  The variable
                 cpaDaPhyDrvStatus indicates the current physical drive status.
    
                 User Action: If cpaDaPhyDrvStatus is 'failed(3)',
                 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)',
                 replace the drive."
    
            --#TYPE "Physical Drive Status Change (3046)"
            --#SUMMARY "Physical drive status is now %d for drive at location %s connected to controller in %s."
            --#ARGUMENTS {11, 5, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY STORAGE
            --#ACTION "If the physical drive status is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)', replace the drive."
            
            ::= 3046
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA-MIB

    Related source files and packages:


    Source location: CPQIDA-MIB::cpqDa7PhyDrvStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:36.136420+00:00.

cpqDa7PhyDrvStatusChange

Status in source: unspecified.

Names: cpqDa7PhyDrvStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqDa7PhyDrvStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqDaCntlrHwLocation",
    ",",
    "cpqDaPhyDrvCntlrIndex",
    ",",
    "cpqDaPhyDrvIndex",
    ",",
    "cpqDaPhyDrvLocationString",
    ",",
    "cpqDaPhyDrvType",
    ",",
    "cpqDaPhyDrvModel",
    ",",
    "cpqDaPhyDrvFWRev",
    ",",
    "cpqDaPhyDrvSerialNum",
    ",",
    "cpqDaPhyDrvFailureCode",
    ",",
    "cpqDaPhyDrvStatus",
    ",",
    "cpqDaPhyDrvBusNumber",
    "}",
    "DESCRIPTION",
    "\"Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is `failed(3)`, `predictiveFailure(4)`, `ssdWearOut(8)`, or `notAuthenticated(9)`, replace the drive.\"",
    "::=",
    "3046"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqDaCntlrHwLocation",
        "cpqDaPhyDrvCntlrIndex",
        "cpqDaPhyDrvIndex",
        "cpqDaPhyDrvLocationString",
        "cpqDaPhyDrvType",
        "cpqDaPhyDrvModel",
        "cpqDaPhyDrvFWRev",
        "cpqDaPhyDrvSerialNum",
        "cpqDaPhyDrvFailureCode",
        "cpqDaPhyDrvStatus",
        "cpqDaPhyDrvBusNumber"
      ]
    ],
    [
      "DESCRIPTION",
      "Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is `failed(3)`, `predictiveFailure(4)`, `ssdWearOut(8)`, or `notAuthenticated(9)`, replace the drive."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQIDA-MIB

    Published definition
    cpqDa7PhyDrvStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
                         cpqDaPhyDrvCntlrIndex, cpqDaPhyDrvIndex,
                         cpqDaPhyDrvLocationString, cpqDaPhyDrvType,
                         cpqDaPhyDrvModel, cpqDaPhyDrvFWRev, cpqDaPhyDrvSerialNum,
                         cpqDaPhyDrvFailureCode, cpqDaPhyDrvStatus,
                         cpqDaPhyDrvBusNumber }
            DESCRIPTION
                "Physical Drive Status Change.
    
                 This trap signifies that the agent has detected a change in the
                 status of a drive array physical drive.  The variable
                 cpaDaPhyDrvStatus indicates the current physical drive status.
    
                 User Action: If cpaDaPhyDrvStatus is `failed(3)`,
                 `predictiveFailure(4)`, `ssdWearOut(8)`, or `notAuthenticated(9)`,
                 replace the drive."
    
            --#TYPE "Physical Drive Status Change (3046)"
            --#SUMMARY "Physical drive status is now %d for drive at location %s connected to controller in %s."
            --#ARGUMENTS {11, 5, 2}
            --#SEVERITY CRITICAL
            --#TIMEINDEX 99
            --#VARBINDSEVERITY 2
            --#SIMPLE_SEVERITY CRITICAL
            --#HWSTATUS_CATEGORY STORAGE
            --#ACTION "If the physical drive status is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)', replace the drive."
            
            ::= 3046
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter', 'Gauge'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQIDA-MIB

    Related source files and packages:


    Source location: CPQIDA-MIB::cpqDa7PhyDrvStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.378273+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.1001 cpqSeCpuThresholdPassed00
1.3.6.1.4.1.232.0.1002 cpqSePCCardThermalDegraded00
1.3.6.1.4.1.232.0.1003 cpqSePCCardThermalFailure00
1.3.6.1.4.1.232.0.1004 cpqSePCCardThermalSafe00
1.3.6.1.4.1.232.0.1005 cpqSe2CpuThresholdPassed00
1.3.6.1.4.1.232.0.1006 cpqSeCpuStatusChange00
1.3.6.1.4.1.232.0.1007 cpqSeCpuPowerPodstatusChange00
1.3.6.1.4.1.232.0.1008 cpqSeUSBStorageDeviceAttached00
1.3.6.1.4.1.232.0.1009 cpqSeUSBStorageDeviceRemoved00
1.3.6.1.4.1.232.0.1010 cpqSeUSBStorageDeviceReadErrorOccurred00
1.3.6.1.4.1.232.0.1011 cpqSeUSBStorageDeviceWriteErrorOccurred00
1.3.6.1.4.1.232.0.1012 cpqSeUSBStorageDeviceRedundancyLost00
1.3.6.1.4.1.232.0.1013 cpqSeUSBStorageDeviceRedundancyRestored00
1.3.6.1.4.1.232.0.1014 cpqSeUSBStorageDeviceSyncFailed00
1.3.6.1.4.1.232.0.1015 cpqSePCIeDiskTemperatureFailed00
1.3.6.1.4.1.232.0.1016 cpqSePCIeDiskTemperatureOk00
1.3.6.1.4.1.232.0.1017 cpqSePCIeDiskConditionChange00
1.3.6.1.4.1.232.0.1018 cpqSePCIeDiskWearStatusChange00
1.3.6.1.4.1.232.0.1019 cpqSePciDeviceAddedOrPoweredOn00
1.3.6.1.4.1.232.0.1020 cpqSePciDeviceRemovedOrPoweredOff00
1.3.6.1.4.1.232.0.1021 cpqSeNVMeSecureEraseFailed00
1.3.6.1.4.1.232.0.1022 cpqSePcieTrainingFailed00
1.3.6.1.4.1.232.0.1023 cpqSePciResetFail00
1.3.6.1.4.1.232.0.1024 cpqSeSecureBootAuthFail00
1.3.6.1.4.1.232.0.1025 cpqSeSecureBootCertAuthFail00
1.3.6.1.4.1.232.0.1026 cpqSeCpuUncorrectableError00
1.3.6.1.4.1.232.0.1027 cpqSeInternalCpuError00
1.3.6.1.4.1.232.0.2001 cpqSiHoodRemoved00
1.3.6.1.4.1.232.0.2002 cpqSiMonitorConditionOK00
1.3.6.1.4.1.232.0.2003 cpqSiMonitorConditionDegraded00
1.3.6.1.4.1.232.0.2004 cpqSiMonitorConditionFailed00
1.3.6.1.4.1.232.0.2005 cpqSiCorrMemErrStatusDegraded00
1.3.6.1.4.1.232.0.2006 cpqSiCorrMemErrStatusOk00
1.3.6.1.4.1.232.0.2007 cpqSiMemConfigChange00
1.3.6.1.4.1.232.0.2008 cpqSiHotPlugSlotBoardRemoved00
1.3.6.1.4.1.232.0.2009 cpqSiHotPlugSlotBoardInserted00
1.3.6.1.4.1.232.0.2010 cpqSiHotPlugSlotPowerUpFailed00
1.3.6.1.4.1.232.0.2011 cpqSiSysBatteryFailure00
1.3.6.1.4.1.232.0.2012 cpqSiSysBatteryChargingDegraded00
1.3.6.1.4.1.232.0.2013 cpqSiSysBatteryCalibrationError00
1.3.6.1.4.1.232.0.2014 cpqSiIntrusionInstalled00
1.3.6.1.4.1.232.0.2015 cpqSiIntrusionRemoved00
1.3.6.1.4.1.232.0.2016 cpqSiHoodReplaced00
1.3.6.1.4.1.232.0.2017 cpqSiHoodRemovedOnPowerOff00
1.3.6.1.4.1.232.0.2018 cpqSiSysTelemetryThresholdAlert00
1.3.6.1.4.1.232.0.3001 cpqDa2LogDrvStatusChange00
1.3.6.1.4.1.232.0.3002 cpqDa2SpareStatusChange00
1.3.6.1.4.1.232.0.3003 cpqDa2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3004 cpqDa2PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3005 cpqDa2AccelStatusChange00