Status in source: unspecified.
Technical details
{
"smi_kind": "TRAP-TYPE",
"definition": [
"cpqHe3ThermalTempDegraded",
"TRAP-TYPE",
"ENTERPRISE",
"compaq",
"VARIABLES",
"{",
"sysName",
",",
"cpqHoTrapFlags",
",",
"cpqHeThermalDegradedAction",
"}",
"DESCRIPTION",
"\"The temperature status has been set to degraded. The server's temperature is outside of the normal operating range. The server will be shutdown if the cpqHeThermalDegradedAction variable is set to shutdown(3).\"",
"::=",
"6018"
],
"syntax_tree": [
[
"objectIdentifier",
[
"compaq"
]
],
[
"VarTypes",
[
"sysName",
"cpqHoTrapFlags",
"cpqHeThermalDegradedAction"
]
],
[
"DESCRIPTION",
"The temperature status has been set to degraded. The server's temperature is outside of the normal operating range. The server will be shutdown if the cpqHeThermalDegradedAction variable is set to shutdown(3)."
],
null
]
}