Reference record for OID 1.3.6.1.4.1.232.0.8001

Parent
1.3.6.1.4.1.232.0 (0)
Node code
8001
Node name
cpqSs2FanStatusChange
Numeric OID
1.3.6.1.4.1.232.0.8001
URN notation
urn:oid:1.3.6.1.4.1.232.0.8001
ASN.1 notation

{1 3 6 1 4 1 232 0 8001}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSs2FanStatusChange(8001)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSs2FanStatusChange(8001)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/8001
  • /ISO/Identified-Organization/6/1/4/1/232/0/8001
  • /ISO/3/6/1/4/1/232/0/8001
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqSs2FanStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqSs2FanStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqSs2FanStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqSs2FanStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqSs2FanStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqSs2FanStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqSs2FanStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqSs2FanStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqSs2FanStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqSs2FanStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqSs2FanStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqSs2FanStatusChange
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqSs2FanStatusChange
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqSs2FanStatusChange
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqSs2FanStatusChange
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqSs2FanStatusChange
  • Additional combinations skipped.

Descriptions

cpqSs2FanStatusChange — MIBdepot

Storage System fan status change. The Insight Agent has detected a change in the Fan Status of a Compaq storage system. The variable cpqSsBoxFanStatus indicates the current fan status.

cpqSs2FanStatusChange — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.

cpqSs2FanStatusChange — MIBdepot

Storage System fan status change. The agent has detected a change in the Fan Status of a Compaq storage system. The variable cpqSsBoxFanStatus indicates the current fan status.

Source records

cpqSs2FanStatusChange

Status in source: unspecified.

Names: cpqSs2FanStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSs2FanStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "cpqSsBoxFanStatus",
    "}",
    "DESCRIPTION",
    "\"Storage System fan status change. The Insight Agent has detected a change in the Fan Status of a Compaq storage system. The variable cpqSsBoxFanStatus indicates the current fan status.\"",
    "::=",
    "8001"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "cpqSsBoxFanStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Storage System fan status change. The Insight Agent has detected a change in the Fan Status of a Compaq storage system. The variable cpqSsBoxFanStatus indicates the current fan status."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSs2FanStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxFanStatus }
            DESCRIPTION
               "Storage System fan status change.
    
                The Insight Agent has detected a change in the Fan Status of a
                Compaq storage system.  The variable cpqSsBoxFanStatus
                indicates the current fan status."
    
                  --#TYPE "Fan Status Change"
                  --#SUMMARY "Storage System fan status changed to %d."
                  --#ARGUMENTS {0}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
            ::= 8001
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download cpqstsys.mib.txt
    Source location: CPQSTSYS-MIB::cpqSs2FanStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:07.892342+00:00.

cpqSs2FanStatusChange

Status in source: unspecified.

Names: cpqSs2FanStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSs2FanStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "cpqSsBoxFanStatus",
    "}",
    "DESCRIPTION",
    "\"Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.\"",
    "::=",
    "8001"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "cpqSsBoxFanStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSs2FanStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxFanStatus }
            DESCRIPTION
               "Storage System fan status change.
    
                The agent has detected a change in the Fan Status of a storage
                system.  The variable cpqSsBoxFanStatus indicates the current
                fan status."
    
                  --#TYPE "Fan Status Change (8001)"
                  --#SUMMARY "Storage System fan status changed to %d."
                  --#ARGUMENTS {0}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
            ::= 8001
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS.MIB.txt
    Source location: CPQSTSYS-MIB::cpqSs2FanStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.794543+00:00.

  • Preserved circitor archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSs2FanStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxFanStatus }
            DESCRIPTION
               "Storage System fan status change.
    
                The agent has detected a change in the Fan Status of a storage
                system.  The variable cpqSsBoxFanStatus indicates the current
                fan status."
    
                  --#TYPE "Fan Status Change (8001)"
                  --#SUMMARY "Storage System fan status changed to %d."
                  --#ARGUMENTS {0}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
            ::= 8001
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS-MIB.mib
    Source location: CPQSTSYS-MIB::cpqSs2FanStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:16.804433+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSTSYS-MIB

    Published definition
    cpqSs2FanStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxFanStatus }
            DESCRIPTION
               "Storage System fan status change.
    
                The agent has detected a change in the Fan Status of a storage
                system.  The variable cpqSsBoxFanStatus indicates the current
                fan status."
    
                  --#TYPE "Fan Status Change (8001)"
                  --#SUMMARY "Storage System fan status changed to %d."
                  --#ARGUMENTS {0}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
            ::= 8001
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS-MIB

    Related source files and packages:


    Source location: CPQSTSYS-MIB::cpqSs2FanStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.413271+00:00.

cpqSs2FanStatusChange

Status in source: unspecified.

Names: cpqSs2FanStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSs2FanStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "cpqSsBoxFanStatus",
    "}",
    "DESCRIPTION",
    "\"Storage System fan status change. The agent has detected a change in the Fan Status of a Compaq storage system. The variable cpqSsBoxFanStatus indicates the current fan status.\"",
    "::=",
    "8001"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "cpqSsBoxFanStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Storage System fan status change. The agent has detected a change in the Fan Status of a Compaq storage system. The variable cpqSsBoxFanStatus indicates the current fan status."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSs2FanStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxFanStatus }
            DESCRIPTION
               "Storage System fan status change.
    
                The agent has detected a change in the Fan Status of a Compaq
                storage system.  The variable cpqSsBoxFanStatus indicates the
                current fan status."
    
                  --#TYPE "Fan Status Change"
                  --#SUMMARY "Storage System fan status changed to %d."
                  --#ARGUMENTS {0}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
            ::= 8001
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS1.MIB.txt
    Source location: CPQSTSYS-MIB::cpqSs2FanStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.795134+00:00.

  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSs2FanStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { cpqSsBoxFanStatus }
            DESCRIPTION
               "Storage System fan status change.
    
                The agent has detected a change in the Fan Status of a Compaq
                storage system.  The variable cpqSsBoxFanStatus indicates the
                current fan status."
    
                  --#TYPE "Fan Status Change"
                  --#SUMMARY "Storage System fan status changed to %d."
                  --#ARGUMENTS {0}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
            ::= 8001
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS2.MIB.txt
    Source location: CPQSTSYS-MIB::cpqSs2FanStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.795732+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.161002 switchConfigFileTransferred00
1.3.6.1.4.1.232.0.161003 switchTFTPTransferSucceeded00
1.3.6.1.4.1.232.0.161004 switchTFTPTransferFailed00
1.3.6.1.4.1.232.0.161005 switchFileInvalid00
1.3.6.1.4.1.232.0.161006 switchFanFailed00
1.3.6.1.4.1.232.0.161007 switchFanOk00
1.3.6.1.4.1.232.0.161008 switchTempSensorDegraded00
1.3.6.1.4.1.232.0.161009 switchTempSensorFailed00
1.3.6.1.4.1.232.0.161010 switchTempSensorOk00
1.3.6.1.4.1.232.0.161011 switchPostSuccess00
1.3.6.1.4.1.232.0.161012 switchLoginFailure00
1.3.6.1.4.1.232.0.161013 switchLocationChange00
1.3.6.1.4.1.232.0.161014 switchCubeTypeChange00
1.3.6.1.4.1.232.0.161015 switchSNTPServiceUnavailable00
1.3.6.1.4.1.232.0.169001 cpqiScsiLinkUp00
1.3.6.1.4.1.232.0.169002 cpqiScsiLinkDown00
1.3.6.1.4.1.232.0.172001 cpqIoDrvWearoutTrap00
1.3.6.1.4.1.232.0.172002 cpqIoDrvNonWritableTrap00
1.3.6.1.4.1.232.0.172003 cpqIoDrvFlashbackTrap00
1.3.6.1.4.1.232.0.172004 cpqIoDrvTempHighTrap00
1.3.6.1.4.1.232.0.172005 cpqIoDrvTempOkTrap00
1.3.6.1.4.1.232.0.172006 cpqIoDrvErrorTrap00
1.3.6.1.4.1.232.0.172007 cpqIoDrvPowerlossProtectTrap00
1.3.6.1.4.1.232.0.179001 cpqOneViewCriticalAlert00
1.3.6.1.4.1.232.0.179002 cpqOneViewWarningAlert00
1.3.6.1.4.1.232.0.179003 cpqOneViewOkAlert00
1.3.6.1.4.1.232.0.179004 cpqOneViewUnknownAlert00
1.3.6.1.4.1.232.0.13600256 sCellEventTrap_1_000
1.3.6.1.4.1.232.0.13600257 sCellEventTrap_1_100
1.3.6.1.4.1.232.0.13600258 sCellEventTrap-01-0200
1.3.6.1.4.1.232.0.13600512 sCellEventTrap-02-0000
1.3.6.1.4.1.232.0.13600768 sCellEventTrap_3_0, sCellEventTrap-03-0000
1.3.6.1.4.1.232.0.13600769 sCellEventTrap_3_1, sCellEventTrap-03-0100
1.3.6.1.4.1.232.0.13600770 sCellEventTrap_3_2, sCellEventTrap-03-0200
1.3.6.1.4.1.232.0.13600771 sCellEventTrap_3_3, sCellEventTrap-03-0300
1.3.6.1.4.1.232.0.13600772 sCellEventTrap_3_4, sCellEventTrap-03-0400
1.3.6.1.4.1.232.0.13600773 sCellEventTrap_3_5, sCellEventTrap-03-0500
1.3.6.1.4.1.232.0.13600774 sCellEventTrap_3_6, sCellEventTrap-03-0600
1.3.6.1.4.1.232.0.13600775 sCellEventTrap_3_7, sCellEventTrap-03-0700
1.3.6.1.4.1.232.0.13600776 sCellEventTrap_3_8, sCellEventTrap-03-0800
1.3.6.1.4.1.232.0.13600777 sCellEventTrap-03-0900
1.3.6.1.4.1.232.0.13600778 sCellEventTrap-03-0a00
1.3.6.1.4.1.232.0.13600779 sCellEventTrap-03-0b00
1.3.6.1.4.1.232.0.13600780 sCellEventTrap-03-0c00
1.3.6.1.4.1.232.0.13600781 sCellEventTrap-03-0d00
1.3.6.1.4.1.232.0.13600782 sCellEventTrap-03-0e00
1.3.6.1.4.1.232.0.13600783 sCellEventTrap-03-0f00
1.3.6.1.4.1.232.0.13600784 sCellEventTrap-03-1000
1.3.6.1.4.1.232.0.13600785 sCellEventTrap-03-1100
1.3.6.1.4.1.232.0.13600786 sCellEventTrap-03-1200