Reference record for OID 1.3.6.1.4.1.232.0.8023

Parent
1.3.6.1.4.1.232.0 (0)
Node code
8023
Node name
cpqSsExBackplaneTempStatusChange
Numeric OID
1.3.6.1.4.1.232.0.8023
URN notation
urn:oid:1.3.6.1.4.1.232.0.8023
ASN.1 notation

{1 3 6 1 4 1 232 0 8023}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSsExBackplaneTempStatusChange(8023)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/8023
  • /ISO/Identified-Organization/6/1/4/1/232/0/8023
  • /ISO/3/6/1/4/1/232/0/8023
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqSsExBackplaneTempStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqSsExBackplaneTempStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqSsExBackplaneTempStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqSsExBackplaneTempStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqSsExBackplaneTempStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqSsExBackplaneTempStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqSsExBackplaneTempStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqSsExBackplaneTempStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqSsExBackplaneTempStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqSsExBackplaneTempStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqSsExBackplaneTempStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqSsExBackplaneTempStatusChange
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqSsExBackplaneTempStatusChange
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqSsExBackplaneTempStatusChange
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqSsExBackplaneTempStatusChange
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqSsExBackplaneTempStatusChange
  • Additional combinations skipped.

Descriptions

cpqSsExBackplaneTempStatusChange — HPE networking MIB copies (LibreNMS/Observium Community)

Storage system temperature status change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If cpqSsBackplaneTempStatus is `degraded(4)` or `failed(5)`, shutdown the storage system as soon as possible. Ensure that the storage system environment is being cooled properly and that no components are overheated.

cpqSsExBackplaneTempStatusChange — Circitor, MIBdepot

Storage system temperature status change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.

cpqSsExBackplaneTempStatusChange — MIBdepot

Storage system temperature status change. The agent has detected a change in the status of the temperature in a Compaq storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.

Source records

cpqSsExBackplaneTempStatusChange

Status in source: unspecified.

Names: cpqSsExBackplaneTempStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSsExBackplaneTempStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSsChassisName",
    ",",
    "cpqSsChassisTime",
    ",",
    "cpqSsBackplaneIndex",
    ",",
    "cpqSsBackplaneVendor",
    ",",
    "cpqSsBackplaneModel",
    ",",
    "cpqSsBackplaneSerialNumber",
    ",",
    "cpqSsBackplaneTempStatus",
    "}",
    "DESCRIPTION",
    "\"Storage system temperature status change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If cpqSsBackplaneTempStatus is `degraded(4)` or `failed(5)`, shutdown the storage system as soon as possible. Ensure that the storage system environment is being cooled properly and that no components are overheated.\"",
    "::=",
    "8023"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSsChassisName",
        "cpqSsChassisTime",
        "cpqSsBackplaneIndex",
        "cpqSsBackplaneVendor",
        "cpqSsBackplaneModel",
        "cpqSsBackplaneSerialNumber",
        "cpqSsBackplaneTempStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Storage system temperature status change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If cpqSsBackplaneTempStatus is `degraded(4)` or `failed(5)`, shutdown the storage system as soon as possible. Ensure that the storage system environment is being cooled properly and that no components are overheated."
    ],
    null
  ]
}
  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSTSYS-MIB

    Published definition
    cpqSsExBackplaneTempStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsChassisName,
                         cpqSsChassisTime, cpqSsBackplaneIndex,
                         cpqSsBackplaneVendor, cpqSsBackplaneModel,
                         cpqSsBackplaneSerialNumber, cpqSsBackplaneTempStatus }
            DESCRIPTION
               "Storage system temperature status change.
    
                The agent has detected a change in the status of the temperature
                in a storage system.  The variable cpqSsBackplaneTempStatus
                indicates the current status.
    
                User Action: If cpqSsBackplaneTempStatus is `degraded(4)` or
                `failed(5)`, shutdown the storage system as soon as possible.
                Ensure that the storage system environment is being cooled properly
                and that no components are overheated."
    
                  --#TYPE "Storage System Temperature Status Change (8023)"
                  --#SUMMARY "Storage system temperature status changed to %d for chassis %s."
                  --#ARGUMENTS {8, 2}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
                  --#VARBINDSEVERITY 2
                  --#SIMPLE_SEVERITY CRITICAL
                  --#HWSTATUS_CATEGORY THERMAL
                  --#ACTION "If the temperature status is 'degraded(4)' or 'failed(5)', shutdown the storage system. Ensure the environment is properly cooled and no components are overheated."      
                                
            ::= 8023
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS-MIB

    Related source files and packages:


    Source location: CPQSTSYS-MIB::cpqSsExBackplaneTempStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.413271+00:00.

cpqSsExBackplaneTempStatusChange

Status in source: unspecified.

Names: cpqSsExBackplaneTempStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSsExBackplaneTempStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSsChassisName",
    ",",
    "cpqSsChassisTime",
    ",",
    "cpqSsBackplaneIndex",
    ",",
    "cpqSsBackplaneVendor",
    ",",
    "cpqSsBackplaneModel",
    ",",
    "cpqSsBackplaneSerialNumber",
    ",",
    "cpqSsBackplaneTempStatus",
    "}",
    "DESCRIPTION",
    "\"Storage system temperature status change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.\"",
    "::=",
    "8023"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSsChassisName",
        "cpqSsChassisTime",
        "cpqSsBackplaneIndex",
        "cpqSsBackplaneVendor",
        "cpqSsBackplaneModel",
        "cpqSsBackplaneSerialNumber",
        "cpqSsBackplaneTempStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Storage system temperature status change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSsExBackplaneTempStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsChassisName,
                         cpqSsChassisTime, cpqSsBackplaneIndex,
                         cpqSsBackplaneVendor, cpqSsBackplaneModel,
                         cpqSsBackplaneSerialNumber, cpqSsBackplaneTempStatus }
            DESCRIPTION
               "Storage system temperature status change.
    
                The agent has detected a change in the status of the temperature
                in a storage system.  The variable cpqSsBackplaneTempStatus
                indicates the current status.
    
                User Action: If the temperature status is degraded or failed,
                shutdown the storage system as soon as possible.  Insure that
                the storage system environment is being cooled properly and that
                no components are overheated."
    
                  --#TYPE "Storage System Temperature Status Change (8023)"
                  --#SUMMARY "Storage system temperature status changed to %d."
                  --#ARGUMENTS {8}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
                  --#VARBINDSEVERITY 2
    
            ::= 8023
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS.MIB.txt
    Source location: CPQSTSYS-MIB::cpqSsExBackplaneTempStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.794543+00:00.

  • Preserved circitor archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSsExBackplaneTempStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsChassisName,
                         cpqSsChassisTime, cpqSsBackplaneIndex,
                         cpqSsBackplaneVendor, cpqSsBackplaneModel,
                         cpqSsBackplaneSerialNumber, cpqSsBackplaneTempStatus }
            DESCRIPTION
               "Storage system temperature status change.
    
                The agent has detected a change in the status of the temperature
                in a storage system.  The variable cpqSsBackplaneTempStatus
                indicates the current status.
    
                User Action: If the temperature status is degraded or failed,
                shutdown the storage system as soon as possible.  Insure that
                the storage system environment is being cooled properly and that
                no components are overheated."
    
                  --#TYPE "Storage System Temperature Status Change (8023)"
                  --#SUMMARY "Storage system temperature status changed to %d."
                  --#ARGUMENTS {8}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
                  --#VARBINDSEVERITY 2
    
            ::= 8023
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS-MIB.mib
    Source location: CPQSTSYS-MIB::cpqSsExBackplaneTempStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:16.804433+00:00.

cpqSsExBackplaneTempStatusChange

Status in source: unspecified.

Names: cpqSsExBackplaneTempStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSsExBackplaneTempStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSsChassisName",
    ",",
    "cpqSsChassisTime",
    ",",
    "cpqSsBackplaneIndex",
    ",",
    "cpqSsBackplaneVendor",
    ",",
    "cpqSsBackplaneModel",
    ",",
    "cpqSsBackplaneSerialNumber",
    ",",
    "cpqSsBackplaneTempStatus",
    "}",
    "DESCRIPTION",
    "\"Storage system temperature status change. The agent has detected a change in the status of the temperature in a Compaq storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.\"",
    "::=",
    "8023"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSsChassisName",
        "cpqSsChassisTime",
        "cpqSsBackplaneIndex",
        "cpqSsBackplaneVendor",
        "cpqSsBackplaneModel",
        "cpqSsBackplaneSerialNumber",
        "cpqSsBackplaneTempStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Storage system temperature status change. The agent has detected a change in the status of the temperature in a Compaq storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSsExBackplaneTempStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsChassisName,
                         cpqSsChassisTime, cpqSsBackplaneIndex,
                         cpqSsBackplaneVendor, cpqSsBackplaneModel,
                         cpqSsBackplaneSerialNumber, cpqSsBackplaneTempStatus }
            DESCRIPTION
               "Storage system temperature status change.
    
                The agent has detected a change in the status of the temperature
                in a Compaq storage system.  The variable
                cpqSsBackplaneTempStatus indicates the current status.
    
                User Action: If the temperature status is degraded or failed,
                shutdown the storage system as soon as possible.  Insure that
                the storage system environment is being cooled properly and that
                no components are overheated."
    
                  --#TYPE "Storage System Temperature Status Change"
                  --#SUMMARY "Storage system temperature status changed to %d."
                  --#ARGUMENTS {8}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
            ::= 8023
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS1.MIB.txt
    Source location: CPQSTSYS-MIB::cpqSsExBackplaneTempStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.795134+00:00.

  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSsExBackplaneTempStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsChassisName,
                         cpqSsChassisTime, cpqSsBackplaneIndex,
                         cpqSsBackplaneVendor, cpqSsBackplaneModel,
                         cpqSsBackplaneSerialNumber, cpqSsBackplaneTempStatus }
            DESCRIPTION
               "Storage system temperature status change.
    
                The agent has detected a change in the status of the temperature
                in a Compaq storage system.  The variable
                cpqSsBackplaneTempStatus indicates the current status.
    
                User Action: If the temperature status is degraded or failed,
                shutdown the storage system as soon as possible.  Insure that
                the storage system environment is being cooled properly and that
                no components are overheated."
    
                  --#TYPE "Storage System Temperature Status Change"
                  --#SUMMARY "Storage system temperature status changed to %d."
                  --#ARGUMENTS {8}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
            ::= 8023
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['enterprises', 'Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS2.MIB.txt
    Source location: CPQSTSYS-MIB::cpqSsExBackplaneTempStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.795732+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.1001 cpqSeCpuThresholdPassed00
1.3.6.1.4.1.232.0.1002 cpqSePCCardThermalDegraded00
1.3.6.1.4.1.232.0.1003 cpqSePCCardThermalFailure00
1.3.6.1.4.1.232.0.1004 cpqSePCCardThermalSafe00
1.3.6.1.4.1.232.0.1005 cpqSe2CpuThresholdPassed00
1.3.6.1.4.1.232.0.1006 cpqSeCpuStatusChange00
1.3.6.1.4.1.232.0.1007 cpqSeCpuPowerPodstatusChange00
1.3.6.1.4.1.232.0.1008 cpqSeUSBStorageDeviceAttached00
1.3.6.1.4.1.232.0.1009 cpqSeUSBStorageDeviceRemoved00
1.3.6.1.4.1.232.0.1010 cpqSeUSBStorageDeviceReadErrorOccurred00
1.3.6.1.4.1.232.0.1011 cpqSeUSBStorageDeviceWriteErrorOccurred00
1.3.6.1.4.1.232.0.1012 cpqSeUSBStorageDeviceRedundancyLost00
1.3.6.1.4.1.232.0.1013 cpqSeUSBStorageDeviceRedundancyRestored00
1.3.6.1.4.1.232.0.1014 cpqSeUSBStorageDeviceSyncFailed00
1.3.6.1.4.1.232.0.1015 cpqSePCIeDiskTemperatureFailed00
1.3.6.1.4.1.232.0.1016 cpqSePCIeDiskTemperatureOk00
1.3.6.1.4.1.232.0.1017 cpqSePCIeDiskConditionChange00
1.3.6.1.4.1.232.0.1018 cpqSePCIeDiskWearStatusChange00
1.3.6.1.4.1.232.0.1019 cpqSePciDeviceAddedOrPoweredOn00
1.3.6.1.4.1.232.0.1020 cpqSePciDeviceRemovedOrPoweredOff00
1.3.6.1.4.1.232.0.1021 cpqSeNVMeSecureEraseFailed00
1.3.6.1.4.1.232.0.1022 cpqSePcieTrainingFailed00
1.3.6.1.4.1.232.0.1023 cpqSePciResetFail00
1.3.6.1.4.1.232.0.1024 cpqSeSecureBootAuthFail00
1.3.6.1.4.1.232.0.1025 cpqSeSecureBootCertAuthFail00
1.3.6.1.4.1.232.0.1026 cpqSeCpuUncorrectableError00
1.3.6.1.4.1.232.0.1027 cpqSeInternalCpuError00
1.3.6.1.4.1.232.0.2001 cpqSiHoodRemoved00
1.3.6.1.4.1.232.0.2002 cpqSiMonitorConditionOK00
1.3.6.1.4.1.232.0.2003 cpqSiMonitorConditionDegraded00
1.3.6.1.4.1.232.0.2004 cpqSiMonitorConditionFailed00
1.3.6.1.4.1.232.0.2005 cpqSiCorrMemErrStatusDegraded00
1.3.6.1.4.1.232.0.2006 cpqSiCorrMemErrStatusOk00
1.3.6.1.4.1.232.0.2007 cpqSiMemConfigChange00
1.3.6.1.4.1.232.0.2008 cpqSiHotPlugSlotBoardRemoved00
1.3.6.1.4.1.232.0.2009 cpqSiHotPlugSlotBoardInserted00
1.3.6.1.4.1.232.0.2010 cpqSiHotPlugSlotPowerUpFailed00
1.3.6.1.4.1.232.0.2011 cpqSiSysBatteryFailure00
1.3.6.1.4.1.232.0.2012 cpqSiSysBatteryChargingDegraded00
1.3.6.1.4.1.232.0.2013 cpqSiSysBatteryCalibrationError00
1.3.6.1.4.1.232.0.2014 cpqSiIntrusionInstalled00
1.3.6.1.4.1.232.0.2015 cpqSiIntrusionRemoved00
1.3.6.1.4.1.232.0.2016 cpqSiHoodReplaced00
1.3.6.1.4.1.232.0.2017 cpqSiHoodRemovedOnPowerOff00
1.3.6.1.4.1.232.0.2018 cpqSiSysTelemetryThresholdAlert00
1.3.6.1.4.1.232.0.3001 cpqDa2LogDrvStatusChange00
1.3.6.1.4.1.232.0.3002 cpqDa2SpareStatusChange00
1.3.6.1.4.1.232.0.3003 cpqDa2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3004 cpqDa2PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3005 cpqDa2AccelStatusChange00