Reference record for OID 1.3.6.1.4.1.232.0.8027

Parent
1.3.6.1.4.1.232.0 (0)
Node code
8027
Node name
cpqSs5TempStatusChange
Numeric OID
1.3.6.1.4.1.232.0.8027
URN notation
urn:oid:1.3.6.1.4.1.232.0.8027
ASN.1 notation

{1 3 6 1 4 1 232 0 8027}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) compaq(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) hp(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) compaq(232) 0 cpqSs5TempStatusChange(8027)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) hp(232) 0 cpqSs5TempStatusChange(8027)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/232/0/8027
  • /ISO/Identified-Organization/6/1/4/1/232/0/8027
  • /ISO/3/6/1/4/1/232/0/8027
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/0/cpqSs5TempStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/hp/0/cpqSs5TempStatusChange
  • /iso/identified-organization/dod/internet/private/enterprise/Compaq/0/cpqSs5TempStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/compaq/0/cpqSs5TempStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/hp/0/cpqSs5TempStatusChange
  • /iso/identified-organization/dod/internet/private/enterprises/Compaq/0/cpqSs5TempStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/compaq/0/cpqSs5TempStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/hp/0/cpqSs5TempStatusChange
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Compaq/0/cpqSs5TempStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/compaq/0/cpqSs5TempStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/hp/0/cpqSs5TempStatusChange
  • /iso/identified-organization/dod/internet/private/vendor-objects/Compaq/0/cpqSs5TempStatusChange
  • /iso/org/dod/internet/private/enterprise/compaq/0/cpqSs5TempStatusChange
  • /iso/org/dod/internet/private/enterprise/hp/0/cpqSs5TempStatusChange
  • /iso/org/dod/internet/private/enterprise/Compaq/0/cpqSs5TempStatusChange
  • /iso/org/dod/internet/private/enterprises/compaq/0/cpqSs5TempStatusChange
  • Additional combinations skipped.

Descriptions

cpqSs5TempStatusChange — Circitor, HPE networking MIB copies (LibreNMS/Observium Community), MIBdepot

Storage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.

Source records

cpqSs5TempStatusChange

Status in source: unspecified.

Names: cpqSs5TempStatusChange

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "cpqSs5TempStatusChange",
    "TRAP-TYPE",
    "ENTERPRISE",
    "compaq",
    "VARIABLES",
    "{",
    "sysName",
    ",",
    "cpqHoTrapFlags",
    ",",
    "cpqSsBoxCntlrHwLocation",
    ",",
    "cpqSsBoxCntlrIndex",
    ",",
    "cpqSsBoxBusIndex",
    ",",
    "cpqSsBoxVendor",
    ",",
    "cpqSsBoxModel",
    ",",
    "cpqSsBoxSerialNumber",
    ",",
    "cpqSsBoxTempStatus",
    "}",
    "DESCRIPTION",
    "\"Storage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.\"",
    "::=",
    "8027"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "compaq"
      ]
    ],
    [
      "VarTypes",
      [
        "sysName",
        "cpqHoTrapFlags",
        "cpqSsBoxCntlrHwLocation",
        "cpqSsBoxCntlrIndex",
        "cpqSsBoxBusIndex",
        "cpqSsBoxVendor",
        "cpqSsBoxModel",
        "cpqSsBoxSerialNumber",
        "cpqSsBoxTempStatus"
      ]
    ],
    [
      "DESCRIPTION",
      "Storage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSs5TempStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsBoxCntlrHwLocation,
                         cpqSsBoxCntlrIndex, cpqSsBoxBusIndex, cpqSsBoxVendor,
                         cpqSsBoxModel, cpqSsBoxSerialNumber, cpqSsBoxTempStatus }
            DESCRIPTION
               "Storage System temperature status change.
    
                The agent has detected a change in the temperature status of a
                storage system.  The variable cpqSsBoxTempStatus indicates the
                current temperature status.
    
                User Action: If the temperature status is degraded or failed,
                shutdown the storage system as soon as possible.  Insure that
                the storage system environment is being cooled properly and that
                no components are overheated."
    
                  --#TYPE "Temperature Status Change (8027)"
                  --#SUMMARY "Storage System temperature status changed to %d."
                  --#ARGUMENTS {8}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
            ::= 8027
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS.MIB.txt
    Source location: CPQSTSYS-MIB::cpqSs5TempStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:08.794543+00:00.

  • Preserved circitor archive

    Module: CPQSTSYS-MIB

    Published definition
    cpqSs5TempStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsBoxCntlrHwLocation,
                         cpqSsBoxCntlrIndex, cpqSsBoxBusIndex, cpqSsBoxVendor,
                         cpqSsBoxModel, cpqSsBoxSerialNumber, cpqSsBoxTempStatus }
            DESCRIPTION
               "Storage System temperature status change.
    
                The agent has detected a change in the temperature status of a
                storage system.  The variable cpqSsBoxTempStatus indicates the
                current temperature status.
    
                User Action: If the temperature status is degraded or failed,
                shutdown the storage system as soon as possible.  Insure that
                the storage system environment is being cooled properly and that
                no components are overheated."
    
                  --#TYPE "Temperature Status Change (8027)"
                  --#SUMMARY "Storage System temperature status changed to %d."
                  --#ARGUMENTS {8}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
            ::= 8027
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS-MIB.mib
    Source location: CPQSTSYS-MIB::cpqSs5TempStatusChange.
    Source version and references

    Archived: 2026-10-19T00:22:16.804433+00:00.

  • HPE networking MIB copies (LibreNMS/Observium Community) · Publisher's source file: Source package: observium-community-latest.tar.gz

    Vendor MIB copy from the Observium Community archive. HPE networking support.

    Module: CPQSTSYS-MIB

    Published definition
    cpqSs5TempStatusChange TRAP-TYPE
            ENTERPRISE compaq
            VARIABLES  { sysName, cpqHoTrapFlags, cpqSsBoxCntlrHwLocation,
                         cpqSsBoxCntlrIndex, cpqSsBoxBusIndex, cpqSsBoxVendor,
                         cpqSsBoxModel, cpqSsBoxSerialNumber, cpqSsBoxTempStatus }
            DESCRIPTION
               "Storage System temperature status change.
    
                The agent has detected a change in the temperature status of a
                storage system.  The variable cpqSsBoxTempStatus indicates the
                current temperature status.
    
                User Action: If the temperature status is degraded or failed,
                shutdown the storage system as soon as possible.  Insure that
                the storage system environment is being cooled properly and that
                no components are overheated."
    
                  --#TYPE "Temperature Status Change (8027)"
                  --#SUMMARY "Storage System temperature status changed to %d."
                  --#ARGUMENTS {8}
                  --#SEVERITY CRITICAL
                  --#TIMEINDEX 99
    
            ::= 8027
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CPQHOST-MIB': ['compaq', 'cpqHoTrapFlags'], 'RFC1155-SMI': ['Counter'], 'RFC1213-MIB': ['DisplayString', 'sysName']}
    · Download CPQSTSYS-MIB

    Related source files and packages:


    Source location: CPQSTSYS-MIB::cpqSs5TempStatusChange.
    Source version and references

    Downloaded: 2026-10-23T19:25:41.413271+00:00.

Siblings (2457)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.232.0.1001 cpqSeCpuThresholdPassed00
1.3.6.1.4.1.232.0.1002 cpqSePCCardThermalDegraded00
1.3.6.1.4.1.232.0.1003 cpqSePCCardThermalFailure00
1.3.6.1.4.1.232.0.1004 cpqSePCCardThermalSafe00
1.3.6.1.4.1.232.0.1005 cpqSe2CpuThresholdPassed00
1.3.6.1.4.1.232.0.1006 cpqSeCpuStatusChange00
1.3.6.1.4.1.232.0.1007 cpqSeCpuPowerPodstatusChange00
1.3.6.1.4.1.232.0.1008 cpqSeUSBStorageDeviceAttached00
1.3.6.1.4.1.232.0.1009 cpqSeUSBStorageDeviceRemoved00
1.3.6.1.4.1.232.0.1010 cpqSeUSBStorageDeviceReadErrorOccurred00
1.3.6.1.4.1.232.0.1011 cpqSeUSBStorageDeviceWriteErrorOccurred00
1.3.6.1.4.1.232.0.1012 cpqSeUSBStorageDeviceRedundancyLost00
1.3.6.1.4.1.232.0.1013 cpqSeUSBStorageDeviceRedundancyRestored00
1.3.6.1.4.1.232.0.1014 cpqSeUSBStorageDeviceSyncFailed00
1.3.6.1.4.1.232.0.1015 cpqSePCIeDiskTemperatureFailed00
1.3.6.1.4.1.232.0.1016 cpqSePCIeDiskTemperatureOk00
1.3.6.1.4.1.232.0.1017 cpqSePCIeDiskConditionChange00
1.3.6.1.4.1.232.0.1018 cpqSePCIeDiskWearStatusChange00
1.3.6.1.4.1.232.0.1019 cpqSePciDeviceAddedOrPoweredOn00
1.3.6.1.4.1.232.0.1020 cpqSePciDeviceRemovedOrPoweredOff00
1.3.6.1.4.1.232.0.1021 cpqSeNVMeSecureEraseFailed00
1.3.6.1.4.1.232.0.1022 cpqSePcieTrainingFailed00
1.3.6.1.4.1.232.0.1023 cpqSePciResetFail00
1.3.6.1.4.1.232.0.1024 cpqSeSecureBootAuthFail00
1.3.6.1.4.1.232.0.1025 cpqSeSecureBootCertAuthFail00
1.3.6.1.4.1.232.0.1026 cpqSeCpuUncorrectableError00
1.3.6.1.4.1.232.0.1027 cpqSeInternalCpuError00
1.3.6.1.4.1.232.0.2001 cpqSiHoodRemoved00
1.3.6.1.4.1.232.0.2002 cpqSiMonitorConditionOK00
1.3.6.1.4.1.232.0.2003 cpqSiMonitorConditionDegraded00
1.3.6.1.4.1.232.0.2004 cpqSiMonitorConditionFailed00
1.3.6.1.4.1.232.0.2005 cpqSiCorrMemErrStatusDegraded00
1.3.6.1.4.1.232.0.2006 cpqSiCorrMemErrStatusOk00
1.3.6.1.4.1.232.0.2007 cpqSiMemConfigChange00
1.3.6.1.4.1.232.0.2008 cpqSiHotPlugSlotBoardRemoved00
1.3.6.1.4.1.232.0.2009 cpqSiHotPlugSlotBoardInserted00
1.3.6.1.4.1.232.0.2010 cpqSiHotPlugSlotPowerUpFailed00
1.3.6.1.4.1.232.0.2011 cpqSiSysBatteryFailure00
1.3.6.1.4.1.232.0.2012 cpqSiSysBatteryChargingDegraded00
1.3.6.1.4.1.232.0.2013 cpqSiSysBatteryCalibrationError00
1.3.6.1.4.1.232.0.2014 cpqSiIntrusionInstalled00
1.3.6.1.4.1.232.0.2015 cpqSiIntrusionRemoved00
1.3.6.1.4.1.232.0.2016 cpqSiHoodReplaced00
1.3.6.1.4.1.232.0.2017 cpqSiHoodRemovedOnPowerOff00
1.3.6.1.4.1.232.0.2018 cpqSiSysTelemetryThresholdAlert00
1.3.6.1.4.1.232.0.3001 cpqDa2LogDrvStatusChange00
1.3.6.1.4.1.232.0.3002 cpqDa2SpareStatusChange00
1.3.6.1.4.1.232.0.3003 cpqDa2PhyDrvStatusChange00
1.3.6.1.4.1.232.0.3004 cpqDa2PhyDrvThreshPassedTrap00
1.3.6.1.4.1.232.0.3005 cpqDa2AccelStatusChange00