IDE Logical Drive OS Name.
The OS name for this logical drive. This field will be a null
(size 0) string if the agent does not support OS name.
Parsed from file CPQIDE1.MIB.txt
Company: None
Module: CPQIDE-MIB
IDE Logical Drive OS Name.
The OS name for this logical drive. This field will be a null
(size 0) string if the agent does not support OS name.
Parsed from file CPQIDE-MIB.mib
Module: CPQIDE-MIB
cpqIdeLogicalDriveOsName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "IDE Logical Drive OS Name. The OS name for this logical drive. This field will be a null (size 0) string if the agent does not support OS name." ::= { cpqIdeLogicalDriveEntry 11 }
Vendor: Compaq
Module: CPQIDE-MIB
[Automatically extracted from oidview.com]
cpqIdeLogicalDriveOsName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "IDE Logical Drive OS Name. The OS name for this logical drive. This field will be a null (size 0) string if the agent does not support OS name." ::= { cpqIdeLogicalDriveEntry 11 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.14.2.6.1.1.1 | cpqIdeLogicalDriveControllerIndex | 0 | 0 | An index that uniquely identifies each controller. |
1.3.6.1.4.1.232.14.2.6.1.1.2 | cpqIdeLogicalDriveIndex | 0 | 0 | An index that uniquely identifies each logical drive. |
1.3.6.1.4.1.232.14.2.6.1.1.3 | cpqIdeLogicalDriveRaidLevel | 0 | 0 | Compaq IDE Logical Drive RAID Level. The following RAID levels are defined: other(1) The agent cannot determine the RAID level of … |
1.3.6.1.4.1.232.14.2.6.1.1.4 | cpqIdeLogicalDriveCapacity | 0 | 0 | IDE Logical Drive Capacity. This is the capacity of the logical drive in megabytes. |
1.3.6.1.4.1.232.14.2.6.1.1.5 | cpqIdeLogicalDriveStatus | 0 | 0 | IDE Logical Drive Status. This is the status of the logical drive. other(1) The agent cannot determine the logical drive status. ok… |
1.3.6.1.4.1.232.14.2.6.1.1.6 | cpqIdeLogicalDriveCondition | 0 | 0 | IDE Logical Drive Condition. This is the condition of the logical drive. |
1.3.6.1.4.1.232.14.2.6.1.1.7 | cpqIdeLogicalDriveDiskIds | 0 | 0 | IDE Logical Drive Disk ID list. This lists the ATA disks drive IDs which are associated with this logical drive. These are the sa… |
1.3.6.1.4.1.232.14.2.6.1.1.8 | cpqIdeLogicalDriveStripeSize | 0 | 0 | IDE Logical Drive Stripe Size. This is the stripe size in kilobytes. |
1.3.6.1.4.1.232.14.2.6.1.1.9 | cpqIdeLogicalDriveSpareIds | 0 | 0 | IDE Logical Drive Spare ID list. This lists the ATA disks drive IDs which are possible spares for this logical drive. These are t… |
1.3.6.1.4.1.232.14.2.6.1.1.10 | cpqIdeLogicalDriveRebuildingDisk | 0 | 0 | IDE Logical Drive Rebuilding Disk. This is the ATA disk that is in the process of rebuilding. If no drive is currently rebuildin… |