1.3.6.1.4.1.232.141.2.8.10
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrExpCab(8) cpqCrExpCabTemperatureCondition(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrExpCab(8) cpqCrExpCabTemperatureCondition(10)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrExpCab(8) cpqCrExpCabTemperatureCondition(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrExpCab(8) cpqCrExpCabTemperatureCondition(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrExpCab(8) cpqCrExpCabTemperatureCondition(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrExpCab(8) cpqCrExpCabTemperatureCondition(10)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrExpCab(8) cpqCrExpCabTemperatureCondition(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrExpCab(8) cpqCrExpCabTemperatureCondition(10)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrExpCab/cpqCrExpCabTemperatureCondition
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqClusteredRAID/cpqCrComponent/cpqCrExpCab/cpqCrExpCabTemperatureCondition
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrExpCab/cpqCrExpCabTemperatureCondition
  • /iso/org/dod/internet/private/enterprise/hp/cpqClusteredRAID/cpqCrComponent/cpqCrExpCab/cpqCrExpCabTemperatureCondition
  • /iso/org/dod/internet/private/enterprises/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrExpCab/cpqCrExpCabTemperatureCondition
  • /iso/org/dod/internet/private/enterprises/hp/cpqClusteredRAID/cpqCrComponent/cpqCrExpCab/cpqCrExpCabTemperatureCondition
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrExpCab/cpqCrExpCabTemperatureCondition
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqClusteredRAID/cpqCrComponent/cpqCrExpCab/cpqCrExpCabTemperatureCondition
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/141/2/8/10

    Description by mibdepot

    Expansion Cabinet temperature condition.

    This value represents the overall condition of the
    temperature in the expansion cabinet.

    Parsed from file CPQCR1.MIB.txt
    Company: None
    Module: CPQCR-MIB

    Description by circitor

    Expansion Cabinet temperature condition.

    This value represents the overall condition of the
    temperature in the expansion cabinet.

    Parsed from file CPQCR-MIB.mib
    Module: CPQCR-MIB

    Information by mibdepot

    cpqCrExpCabTemperatureCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Expansion Cabinet temperature condition. This value represents the overall condition of the temperature in the expansion cabinet." ::= { cpqCrExpCab 10 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQCR-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqCrExpCabTemperatureCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Expansion Cabinet temperature condition. This value represents the overall condition of the temperature in the expansion cabinet." ::= { cpqCrExpCab 10 }

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.141.2.8.10.0 cpqCrExpCabTemperatureCondition 0 0 None

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.141.2.8.1 cpqCrExpCabPowerSupplyStatus 1 1 Expansion Cabinet power supply status.

    The expansion cabinet power supply status is:

    OK (2)
    Status is normal. Either redundant pow…
    1.3.6.1.4.1.232.141.2.8.2 cpqCrExpCabFanStatus 1 1 Expansion Cabinet fan status.

    The expansion cabinet fan status is:

    OK (2)
    Status is normal. One or more fans is installed and no
    er…
    1.3.6.1.4.1.232.141.2.8.3 cpqCrExpCabTemperatureStatus 1 1 Expansion Cabinet temperature status.

    The expansion cabinet temperature status is:

    OK (2)
    Status is normal.

    Critical (3)
    Critical te…
    1.3.6.1.4.1.232.141.2.8.6 cpqCrExpCabCondition 1 1 Expansion Cabinet condition.

    This value represents the overall condition of the
    expansion cabinet.
    1.3.6.1.4.1.232.141.2.8.7 cpqCrExpCabPowerSupplyCondition 1 1 Expansion Cabinet power supply condition.

    This value represents the overall condition of the
    power supply in the expansion cabine…
    1.3.6.1.4.1.232.141.2.8.9 cpqCrExpCabFanCondition 1 1 Expansion Cabinet fan condition.

    This value represents the overall condition of the
    fan in the expansion cabinet.