Status access, for future use
Parsed from file CPQCMC.MIB.txt
Company: None
Module: CPQCMC-MIB
Status access, for future use
Parsed from file CPQCMC-MIB.mib
Module: CPQCMC-MIB
cpqCmcStatusAccess OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Status access, for future use" ::= { cpqCmcControl 1 }
Vendor: Compaq
Module: CPQCMC-MIB
[Automatically extracted from oidview.com]
cpqCmcStatusAccess OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "Status access, for future use" ::= { cpqCmcControl 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.153.2.2.5.1.0 | cpqCmcStatusAccess | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.153.2.2.5.2 | cpqCmcSetLock1Lock | 1 | 1 | Set door locking device 1, see table With this command the management-station can set the conditions for the door locking device (… |
1.3.6.1.4.1.232.153.2.2.5.3 | cpqCmcSetLock1Key | 1 | 1 | Enable or disable unlocking of the rack-door with external components like keypad or remote input. With this command the manageme… |
1.3.6.1.4.1.232.153.2.2.5.4 | cpqCmcSetLock2Lock | 1 | 1 | Set door locking device 2, see table With this command the management-station can set the conditions for the door locking device (… |
1.3.6.1.4.1.232.153.2.2.5.5 | cpqCmcSetLock2Key | 1 | 1 | Enable or disable unlocking of the rack-door with external components like keypad or remote input. With this command the manageme… |
1.3.6.1.4.1.232.153.2.2.5.6 | cpqCmcSetMessage | 1 | 1 | Set message to CMC, for future use |
1.3.6.1.4.1.232.153.2.2.5.7 | cpqCmcSetAlarm1 | 1 | 1 | Is used to set an alarm in the CMC from the management-station. With this command the management-station can i.e. switch on an al… |
1.3.6.1.4.1.232.153.2.2.5.8 | cpqCmcSetAlarm2 | 1 | 1 | Is used to set an alarm in the CMC from the management-station. With this command the management-station can i.e. switch on an al… |
1.3.6.1.4.1.232.153.2.2.5.9 | cpqCmcSetFan1 | 1 | 1 | Is used for run and stop control of fan1. (2) fan will run and stop according to temperature of sensor 1 and threshold of fan1 (3)… |
1.3.6.1.4.1.232.153.2.2.5.10 | cpqCmcSetFan2 | 1 | 1 | Is used for run and stop control of fan2. (2) fan will run and stop according to temperature of sensor 2 and threshold of fan2 (3)… |
1.3.6.1.4.1.232.153.2.2.5.11 | cpqCmcSetQuitRelay1 | 1 | 1 | Status and quit of alarm relay 1. (2) relay is switched because of an alarm (3) relay is not switched, no alarm (4) (set) will qui… |
1.3.6.1.4.1.232.153.2.2.5.12 | cpqCmcSetQuitRelay2 | 1 | 1 | Status and quit of alarm relay 2. (2) relay is switched because of an alarm (3) relay is not switched, no alarm (4) (set) will qui… |