Reference record for OID 1.3.6.1.4.1.232.16.2.2.2.1.6



parent
1.3.6.1.4.1.232.16.2.2.2.1 (cpqFcaAccelEntry)
node code
6
node name
cpqFcaAccelBatteryStatus
dot oid
1.3.6.1.4.1.232.16.2.2.2.1.6
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaCntlr(2) cpqFcaAccelTable(2) cpqFcaAccelEntry(1) cpqFcaAccelBatteryStatus(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaCntlr(2) cpqFcaAccelTable(2) cpqFcaAccelEntry(1) cpqFcaAccelBatteryStatus(6)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaCntlr(2) cpqFcaAccelTable(2) cpqFcaAccelEntry(1) cpqFcaAccelBatteryStatus(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaCntlr(2) cpqFcaAccelTable(2) cpqFcaAccelEntry(1) cpqFcaAccelBatteryStatus(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaCntlr(2) cpqFcaAccelTable(2) cpqFcaAccelEntry(1) cpqFcaAccelBatteryStatus(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaCntlr(2) cpqFcaAccelTable(2) cpqFcaAccelEntry(1) cpqFcaAccelBatteryStatus(6)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaCntlr(2) cpqFcaAccelTable(2) cpqFcaAccelEntry(1) cpqFcaAccelBatteryStatus(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaCntlr(2) cpqFcaAccelTable(2) cpqFcaAccelEntry(1) cpqFcaAccelBatteryStatus(6)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaCntlr/cpqFcaAccelTable/cpqFcaAccelEntry/cpqFcaAccelBatteryStatus
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaCntlr/cpqFcaAccelTable/cpqFcaAccelEntry/cpqFcaAccelBatteryStatus
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaCntlr/cpqFcaAccelTable/cpqFcaAccelEntry/cpqFcaAccelBatteryStatus
  • /iso/org/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaCntlr/cpqFcaAccelTable/cpqFcaAccelEntry/cpqFcaAccelBatteryStatus
  • /iso/org/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaCntlr/cpqFcaAccelTable/cpqFcaAccelEntry/cpqFcaAccelBatteryStatus
  • /iso/org/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaCntlr/cpqFcaAccelTable/cpqFcaAccelEntry/cpqFcaAccelBatteryStatus
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaCntlr/cpqFcaAccelTable/cpqFcaAccelEntry/cpqFcaAccelBatteryStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaCntlr/cpqFcaAccelTable/cpqFcaAccelEntry/cpqFcaAccelBatteryStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/16/2/2/2/1/6

    Description by mibdepot

    Array Accelerator Board Battery Status.

    This monitors the status of each battery pack on the board. The
    batteries can only recharge when the system has power applied.

    The following values are valid:

    Other (1)
    Indicates that the instrument agent does not recognize
    battery status. You may need to update your software.

    Ok (2)
    Indicates that a particular battery pack is fully charged.

    Charging (3)
    The battery power is less than 75%. The array controller
    is attempting to recharge the battery. A battery can take
    as long as 36 hours to fully recharge. After 36 hours,
    if the battery has not recharged, it is considered failed.

    Failed (4)
    The battery pack is below the sufficient voltage level and
    has not recharged in 36 hours. Your Array Accelerator board
    needs to be serviced.

    Degraded (5)
    The battery is still operating, however, one of the batteries
    in the pack has failed to recharge properly. Your Array
    Accelerator board should be serviced as soon as possible.

    NotPresent (6)
    There are no batteries associated with this controller.

    Parsed from file CPQFCA2.MIB.txt
    Company: None
    Module: CPQFCA-MIB

    Description by circitor

    Array Accelerator Board Battery Status.

    This monitors the status of each battery pack on the board. The
    batteries can only recharge when the system has power applied.

    The following values are valid:

    Other (1)
    Indicates that the instrument agent does not recognize
    battery status. You may need to update your software.

    Ok (2)
    Indicates that a particular battery pack is fully charged.

    Charging (3)
    The battery power is less than 75%. The array controller
    is attempting to recharge the battery. A battery can take
    as long as 36 hours to fully recharge. After 36 hours,
    if the battery has not recharged, it is considered failed.

    Failed (4)
    The battery pack is below the sufficient voltage level and
    has not recharged in 36 hours. Your Array Accelerator board
    needs to be serviced.

    Degraded (5)
    The battery is still operating, however, one of the batteries
    in the pack has failed to recharge properly. Your Array
    Accelerator board should be serviced as soon as possible.

    NotPresent (6)
    There are no batteries associated with this controller.

    Parsed from file CPQFCA-MIB.mib
    Module: CPQFCA-MIB

    Information by mibdepot

    cpqFcaAccelBatteryStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), recharging(3), failed(4), degraded(5), notPresent(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Array Accelerator Board Battery Status. This monitors the status of each battery pack on the board. The batteries can only recharge when the system has power applied. The following values are valid: Other (1) Indicates that the instrument agent does not recognize battery status. You may need to update your software. Ok (2) Indicates that a particular battery pack is fully charged. Charging (3) The battery power is less than 75%. The array controller is attempting to recharge the battery. A battery can take as long as 36 hours to fully recharge. After 36 hours, if the battery has not recharged, it is considered failed. Failed (4) The battery pack is below the sufficient voltage level and has not recharged in 36 hours. Your Array Accelerator board needs to be serviced. Degraded (5) The battery is still operating, however, one of the batteries in the pack has failed to recharge properly. Your Array Accelerator board should be serviced as soon as possible. NotPresent (6) There are no batteries associated with this controller." ::= { cpqFcaAccelEntry 6 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQFCA-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqFcaAccelBatteryStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), recharging(3), failed(4), degraded(5), notPresent(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Array Accelerator Board Battery Status. This monitors the status of each battery pack on the board. The batteries can only recharge when the system has power applied. The following values are valid: Other (1) Indicates that the instrument agent does not recognize battery status. You may need to update your software. Ok (2) Indicates that a particular battery pack is fully charged. Charging (3) The battery power is less than 75%. The array controller is attempting to recharge the battery. A battery can take as long as 36 hours to fully recharge. After 36 hours, if the battery has not recharged, it is considered failed. Failed (4) The battery pack is below the sufficient voltage level and has not recharged in 36 hours. Your Array Accelerator board needs to be serviced. Degraded (5) The battery is still operating, however, one of the batteries in the pack has failed to recharge properly. Your Array Accelerator board should be serviced as soon as possible. NotPresent (6) There are no batteries associated with this controller." ::= { cpqFcaAccelEntry 6 }

    Brothers (13)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.16.2.2.2.1.1 cpqFcaAccelBoxIndex 0 0 External Array Controller Storage Box Index.

    The storage box index indicates which storage box this
    accelerator is in.
    1.3.6.1.4.1.232.16.2.2.2.1.2 cpqFcaAccelBoxIoSlot 0 0 External Array Controller Box I/O Slot.

    This identifies the physical I/O slot where this accelerator
    resides in the storage box.
    1.3.6.1.4.1.232.16.2.2.2.1.3 cpqFcaAccelStatus 0 0 Array Accelerator Board Status.

    This describes the status of the Array Accelerator Cache.

    The status can be:

    Other (1)
    Indicates th…
    1.3.6.1.4.1.232.16.2.2.2.1.4 cpqFcaAccelBadData 0 0 Array Accelerator Board Bad Data.

    The following values are valid:

    None (2)
    Indicates that no data loss occurred. The battery pack…
    1.3.6.1.4.1.232.16.2.2.2.1.5 cpqFcaAccelErrCode 0 0 Array Accelerator Board Error Code.

    Use this to determine the status of the write cache operations.

    The status can be:

    Other (1)
    In…
    1.3.6.1.4.1.232.16.2.2.2.1.7 cpqFcaAccelReadErrs 0 0 Array Accelerator Board Read Errors.

    This shows the total number of read memory parity errors that
    were detected while reading fr…
    1.3.6.1.4.1.232.16.2.2.2.1.8 cpqFcaAccelWriteErrs 0 0 Array Accelerator Board Write Errors.

    This shows the total number of write memory parity errors that
    were detected while writing …
    1.3.6.1.4.1.232.16.2.2.2.1.9 cpqFcaAccelCondition 0 0 The condition of the device. This value represents the overall
    condition of this array accelerator.
    1.3.6.1.4.1.232.16.2.2.2.1.10 cpqFcaAccelWriteCache 0 0 Write Cache Memory.

    This shows the amount of memory allocated for the write cache in
    megabytes. Because data is kept in duplicat…
    1.3.6.1.4.1.232.16.2.2.2.1.11 cpqFcaAccelReadCache 0 0 Read Cache Memory.

    This shows the amount of memory allocated for the read cache in
    megabytes.
    1.3.6.1.4.1.232.16.2.2.2.1.12 cpqFcaAccelSerialNumber 0 0 Array Accelerator Board Serial Number.

    This value can be used to further identify the cache
    controller. If the serial number is …
    1.3.6.1.4.1.232.16.2.2.2.1.13 cpqFcaAccelTotalMemory 0 0 Array Accelerator Total Memory.

    This value is the total amount of accelerator memory in
    megabytes, including both battery-backed …
    1.3.6.1.4.1.232.16.2.2.2.1.14 cpqFcaAccelFailedBatteries 0 0 Array Accelerator Failed Batteries.

    This lists the location of accelerator failed batteries.
    Each octet present contains the posi…