Compaq Fibre Channel Tape Drive Entry.
Parsed from file CPQFCA2.MIB.txt
Company: None
Module: CPQFCA-MIB
Fibre Channel Tape Drive Entry.
Parsed from file CPQFCA-MIB.mib
Module: CPQFCA-MIB
cpqFcTapeDriveEntry OBJECT-TYPE SYNTAX CpqFcTapeDriveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Compaq Fibre Channel Tape Drive Entry." INDEX { cpqFcTapeDriveCntlrIndex, cpqFcTapeDriveScsiBus, cpqFcTapeDriveScsiTarget, cpqFcTapeDriveScsiLun } ::= { cpqFcTapeDriveTable 1 }
Vendor: Compaq
Module: CPQFCA-MIB
[Automatically extracted from oidview.com]
cpqFcTapeDriveEntry OBJECT-TYPE SYNTAX CpqFcTapeDriveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Fibre Channel Tape Drive Entry." INDEX { cpqFcTapeDriveCntlrIndex, cpqFcTapeDriveScsiBus, cpqFcTapeDriveScsiTarget, cpqFcTapeDriveScsiLun } ::= { cpqFcTapeDriveTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.16.3.3.1.1.1 | cpqFcTapeDriveCntlrIndex | 0 | 0 | External Tape Drive Controller Index. This value is a logical number whose meaning is OS dependent. For tape controller has one u… |
1.3.6.1.4.1.232.16.3.3.1.1.2 | cpqFcTapeDriveScsiBus | 0 | 0 | External Tape Drive Scsi Bus. The bus index indicates to which SCSI bus instance on a tape controller this table entry belongs. |
1.3.6.1.4.1.232.16.3.3.1.1.3 | cpqFcTapeDriveScsiTarget | 0 | 0 | External Tape Drive Scsi Target. The target index indicates to which SCSI ID on a tape controller SCSI bus this table entry belon… |
1.3.6.1.4.1.232.16.3.3.1.1.4 | cpqFcTapeDriveScsiLun | 0 | 0 | External Tape Drive Scsi Lun. The Lun index indicates to which logical unit on a SCSI ID on a tape controller SCSI bus this table… |
1.3.6.1.4.1.232.16.3.3.1.1.5 | cpqFcTapeDriveSerialNumber | 0 | 0 | External Tape Drive Serial Number. This is the unit serial number for the tape drive. It can be used for identification purposes. |
1.3.6.1.4.1.232.16.3.3.1.1.6 | cpqFcTapeDriveModel | 0 | 0 | External Tape Drive Model. This is the model name of the tape drive. It can be used for identification purposes. |
1.3.6.1.4.1.232.16.3.3.1.1.7 | cpqFcTapeDriveFWRev | 0 | 0 | External Tape Drive Firmware Revision. This is firmware revision level of the tape drive. It can be used for identification purp… |
1.3.6.1.4.1.232.16.3.3.1.1.8 | cpqFcTapeDriveType | 0 | 0 | External Tape Drive Type. This is the drive type. It can be used for identification purposes. The following values are defined:… |
1.3.6.1.4.1.232.16.3.3.1.1.9 | cpqFcTapeDriveFWSubtype | 0 | 0 | External Tape Drive Firmware Subtype. This is used to differentiate the firmware versions which have the same tape drive type (as… |
1.3.6.1.4.1.232.16.3.3.1.1.10 | cpqFcTapeDriveStatus | 0 | 0 | External Tape Drive Status. The tape drive can be in one of the following states: other(1) The tape drive is in a state other than… |
1.3.6.1.4.1.232.16.3.3.1.1.11 | cpqFcTapeDriveCleanReq | 0 | 0 | External Tape Drive Cleaning Required. This is an indication of whether the tape drive heads require a cleaning session to occur.… |
1.3.6.1.4.1.232.16.3.3.1.1.12 | cpqFcTapeDriveCleanTapeRepl | 0 | 0 | External Tape Drive Cleaning Tape Replacement. This variable is only applicable to autoloader tape drives. This variable indicate… |
1.3.6.1.4.1.232.16.3.3.1.1.13 | cpqFcTapeDriveCondition | 0 | 0 | External Tape Drive Condition. This value represents the overall condition of the tape drive. |
1.3.6.1.4.1.232.16.3.3.1.1.14 | cpqFcTapeDriveCleanTapeCount | 0 | 0 | External Tape Drive Cleaning Tape Count. This variable is a count from a tape drive of the number of cleanings done by the tape c… |
1.3.6.1.4.1.232.16.3.3.1.1.15 | cpqFcTapeDriveLibraryDrive | 0 | 0 | External Tape Drive Library Drive. This variable indicates whether or not the tape drive is part of a tape library. It can be in… |
1.3.6.1.4.1.232.16.3.3.1.1.16 | cpqFcTapeDriveLocation | 0 | 0 | External Tape Drive Location. This is the location of the tape drive. |
1.3.6.1.4.1.232.16.3.3.1.1.17 | cpqFcTapeDriveHotPlug | 0 | 0 | External Tape Drive Hot Plug Support Status. The following values are defined: other(1) The agent is unable to determine if this d… |
1.3.6.1.4.1.232.16.3.3.1.1.18 | cpqFcTapeDriveBay | 0 | 0 | External Tape Drive Bay. For drives in a hot plug storage system, this is the bay where the tape drive is located. If the value … |
1.3.6.1.4.1.232.16.3.3.1.1.19 | cpqFcTapeDriveCurrentWidth | 0 | 0 | External Tape Drive Current Width. The following values are defined: other(1) The agent is unable to determine the current negotia… |
1.3.6.1.4.1.232.16.3.3.1.1.20 | cpqFcTapeDriveCurrentSpeed | 0 | 0 | External Tape Drive Current Data Transfer Speed. The following values are defined: other(1) The agent is unable to determine the c… |